Cone-beam Micro-CT system based on LabVIEW software

被引:36
|
作者
Ionita, Ciprian N. [1 ]
Hoffmann, Keneth R. [1 ]
Bednarek, Daniel R. [1 ]
Chityala, Ravishankar [1 ]
Rudin, Stephen [1 ]
机构
[1] SUNY Buffalo, Toshiba Stroke Res Ctr, Buffalo, NY 14214 USA
关键词
Cone-beam micro-CT; graphical user interface; software design; LabVIEW;
D O I
10.1007/s10278-007-9024-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Construction of a cone-beam computed tomography (CBCT) system for laboratory research usually requires integration of different software and hardware components. As a result, building and operating such a complex system require the expertise of researchers with significantly different backgrounds. Additionally, writing flexible code to control the hardware components of a CBCT system combined with designing a friendly graphical user interface (GUI) can be cumbersome and time consuming. An intuitive and flexible program structure, as well as the program GUI for CBCT acquisition, is presented in this note. The program was developed in National Instrument's Laboratory Virtual Instrumentation Engineering Workbench (LabVIEW) graphical language and is designed to control a custom-built CBCT system but has been also used in a standard angiographic suite. The hardware components are commercially available to researchers and are in general provided with software drivers which are LabVIEW compatible. The program structure was designed as a sequential chain. Each step in the chain takes care of one or two hardware commands at a time; the execution of the sequence can be modified according to the CBCT system design. We have scanned and reconstructed over 200 specimens using this interface and present three examples which cover different areas of interest encountered in laboratory research. The resulting 3D data are rendered using a commercial workstation. The program described in this paper is available for use or improvement by other researchers.
引用
收藏
页码:296 / 305
页数:10
相关论文
共 50 条
  • [1] Cone-Beam Micro-CT System Based on LabVIEW Software
    Ciprian N. Ionita
    Keneth R. Hoffmann
    Daniel R. Bednarek
    Ravishankar Chityala
    Stephen Rudin
    Journal of Digital Imaging, 2008, 21 : 296 - 305
  • [2] Cone-beam reconstruction for micro-CT
    Wang, G
    Jiang, M
    Lee, SW
    Liu, H
    Hoffman, E
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 384 - 387
  • [3] Self-calibration of a cone-beam micro-CT system
    Patel, V.
    Chityala, R. N.
    Hoffmann, K. R.
    Ionita, C. N.
    Bednarek, D. R.
    Rudin, S.
    MEDICAL PHYSICS, 2009, 36 (01) : 48 - 58
  • [4] Simulation of mechanical misalignments in a cone-beam micro-CT system
    Vidal-Migallon, I.
    Abella, M.
    Sisniega, A.
    Vaquero, J. J.
    Desco, M.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4273 - 4275
  • [5] HELICAL DUAL SOURCE CONE-BEAM MICRO-CT
    Johnston, Samuel M.
    Johnson, G. Allan
    Badea, Cristian T.
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 177 - 180
  • [6] Framework for iterative cone-beam micro-CT reconstruction
    Benson, T
    Gregor, J
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3253 - 3257
  • [7] Framework for iterative cone-beam micro-CT reconstruction
    Benson, TM
    Gregor, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1335 - 1340
  • [8] LabView algorithm for control of cone beam micro-CT machine
    Ionita, C
    Chityala, R
    Kyprianou, I
    Dinu, P
    Rudin, S
    Hoffmann, K
    Bednarek, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1849 - 1849
  • [9] Geometric Parameters Estimation and Calibration in Cone-Beam Micro-CT
    Zhao, Jintao
    Hu, Xiaodong
    Zou, Jing
    Hu, Xiaotang
    SENSORS, 2015, 15 (09) : 22811 - 22825
  • [10] Comparative evaluation of cone-beam CT equipment with micro-CT in the visualization of root canal system
    Szabo, Bence Tamas
    Pataky, Levente
    Mikusi, Regina
    Fejerdy, Pal
    Dobo-Nagy, Csaba
    ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2012, 48 (01): : 49 - 52