Cone-beam Micro-CT system based on LabVIEW software

被引:36
|
作者
Ionita, Ciprian N. [1 ]
Hoffmann, Keneth R. [1 ]
Bednarek, Daniel R. [1 ]
Chityala, Ravishankar [1 ]
Rudin, Stephen [1 ]
机构
[1] SUNY Buffalo, Toshiba Stroke Res Ctr, Buffalo, NY 14214 USA
关键词
Cone-beam micro-CT; graphical user interface; software design; LabVIEW;
D O I
10.1007/s10278-007-9024-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Construction of a cone-beam computed tomography (CBCT) system for laboratory research usually requires integration of different software and hardware components. As a result, building and operating such a complex system require the expertise of researchers with significantly different backgrounds. Additionally, writing flexible code to control the hardware components of a CBCT system combined with designing a friendly graphical user interface (GUI) can be cumbersome and time consuming. An intuitive and flexible program structure, as well as the program GUI for CBCT acquisition, is presented in this note. The program was developed in National Instrument's Laboratory Virtual Instrumentation Engineering Workbench (LabVIEW) graphical language and is designed to control a custom-built CBCT system but has been also used in a standard angiographic suite. The hardware components are commercially available to researchers and are in general provided with software drivers which are LabVIEW compatible. The program structure was designed as a sequential chain. Each step in the chain takes care of one or two hardware commands at a time; the execution of the sequence can be modified according to the CBCT system design. We have scanned and reconstructed over 200 specimens using this interface and present three examples which cover different areas of interest encountered in laboratory research. The resulting 3D data are rendered using a commercial workstation. The program described in this paper is available for use or improvement by other researchers.
引用
收藏
页码:296 / 305
页数:10
相关论文
共 50 条
  • [31] Comparison of fan-beam, cone-beam and spiral scan reconstruction in X-ray micro-CT
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 124 - 131
  • [32] Magnitude and effects of X-ray scatter of a cone-beam micro-CT for small animal imaging
    Ni, Y. C.
    Jan, M. L.
    Chen, K. W.
    Cheng, Y. D.
    Chuang, K. S.
    Fu, Y. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 245 - 249
  • [33] An Adaptive Genetic Algorithm for Misalignment Estimation (AGAME) in Spiral, Sequential and Circular Cone-Beam Micro-CT
    Sawall, Stefan
    Knaup, Michael
    Kachelriess, Marc
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3700 - 3704
  • [34] Application of cone-beam micro-CT on high-speed Diesel flows and quantitative cavitation measurements
    Mitroglou, N.
    Lorenzi, M.
    Santini, M.
    Gavaises, M.
    Assanis, D.
    9TH INTERNATIONAL SYMPOSIUM ON CAVITATION (CAV2015), 2015, 656
  • [35] X-ray micro-CT with a displaced detector array: Application to helical cone-beam reconstruction
    Liu, V
    Lariviere, NR
    Wang, G
    MEDICAL PHYSICS, 2003, 30 (10) : 2758 - 2761
  • [36] A preliminary study of few-view image reconstruction of sparse objects in cone-beam micro-CT
    Han, Xiao
    Bian, Junguo
    Eaker, Diane R.
    Sidky, Emil Y.
    Ritman, Erik L.
    Pan, Xiaochuan
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [37] Implementation of dual- and triple-energy cone-beam micro-CT for postreconstruction material decomposition
    Granton, P. V.
    Pollmann, S. I.
    Ford, N. L.
    Drangova, M.
    Holdsworth, D. W.
    MEDICAL PHYSICS, 2008, 35 (11) : 5030 - 5042
  • [38] Standardization of mineral density maps of physiologic and pathologic biominerals in humans using cone-beam CT and micro-CT scanners
    Srirangapatanam, Sudarshan
    Kang, Misun
    Ellenikiotis, Yianni
    Jheon, Andrew
    Kapila, Sunil
    Swana, Hubert S.
    Stoller, Marshall L.
    Seo, Youngho
    Ho, Sunita P.
    DENTAL MATERIALS, 2022, 38 (06) : 989 - 1003
  • [39] Potential of software-based scatter corrections in cone-beam volume CT
    Bertram, M
    Wiegert, J
    Rose, G
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 259 - 270
  • [40] A Hybrid Approach to Reduce Cone-Beam Artifacts for a Circular Orbit Cone-Beam CT System
    Choi, Shinkook
    Kim, Jinsung
    Baek, Jongduk
    IEEE ACCESS, 2018, 6 : 54595 - 54606