Background: A variety of energy-based techniques for arterial and venous vessel ligation have recently been introduced. Using a porcine model we studied the efficacy of the novel reusable BiClamp versus the standard disposable LigaSure bipolar vessel sealing device. We also compared whether arteries respond differently than veins upon sealing. Materials and Methods: In five Swabian Hall pigs, splenectomy and nephrectomy were performed using two different bipolar vessel sealing devices. Measurements of the sealed arteries and veins (diameter 2-7 mm) included rate of seal failure, burst strength, and heat-associated vascular wall morphologic appearance. An additional three animals underwent splenectomy, salpingo-oophorectomy, and small bowel resection, and vessel seals were studied histologically after a seven-day survival period for vessel wall fusion, inflammation, and fibrous organization. Results: Sealing was highly successful, with only one seal failure overall and thus no difference between the two instruments analyzed. The burst pressures of BiClamp-sealed arteries (842 +/- 117 mm Hg) did not differ from that of arteries sealed with LigaSure (856 +/- 102 mm Hg), but were significantly higher than the burst pressures of veins (155 +/- 26 and 216 +/- 71 mm Hg, respectively) (P < 0.05). Independent of the sealing device used, thermal spread was found increased in veins compared to arteries. Histologic analysis after seven days revealed appropriate healing of the vessel wall, including thrombus fibrosis, fibroblast proliferation, and collagen deposition. With both devices, however, the venous but not the arterial walls still presented with massive inflammatory cell infiltrates. Conclusion: Our study indicates that the BiClamp device is as appropriate as the LigaSure instrument to successfully ligate 2-7 mm arteries and veins, demonstrating supraphysiological bursting strengths and adequate lumenal fusion healing. However, veins are more prone to collateral tissue damage and inflammatory wall infiltration.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [1] Evaluation of the novel bipolar vessel sealing and cutting device BiCision® in a porcine model
    Szyrach, Mara Natascha
    Paschenda, Pascal
    Afify, Mamdouh
    Schaeller, Daniel
    Tolba, Rene Hany
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2012, 21 (06) : 402 - 407
  • [2] Use of a bipolar vessel sealing device in canine orchiectomy
    Kanca, Halit
    Yaman, Ceren
    REPRODUCTION IN DOMESTIC ANIMALS, 2022, 57 : 48 - 48
  • [3] Use of a bipolar vessel sealing device in canine orchiectomy
    Yaman, Ceren
    Kanca, Halit
    ANKARA UNIVERSITESI VETERINER FAKULTESI DERGISI, 2023, 70 (04): : 375 - 382
  • [4] The Nightknife©: Evaluation of Efficiency and Quality of Bipolar Vessel Sealing
    Schuld, Jochen
    Sperling, Jens
    Kollmar, Otto
    Menger, Michael D.
    Schilling, Martin K.
    Richter, Sven
    Laschke, Matthias W.
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2011, 21 (07): : 659 - 663
  • [5] Use of a bipolar vessel-sealing device in resection of canine insulinoma
    Wouters, E. G. H.
    Buishand, F. O.
    Kik, M.
    Kirpensteijn, J.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2011, 52 (03) : 139 - 145
  • [6] Heat Transfer Simulation for Design of Electrothermal Bipolar Vessel Sealing Device
    Kim, Seongjun
    Choi, Jaesoon
    2015 15TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2015, : 1853 - 1856
  • [7] Bipolar Electrosurgical Vessel-Sealing Device With Compressive Force Monitoring
    Chen, Roland K.
    Chastagner, Matthew W.
    Geiger, James D.
    Shih, Albert J.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (06):
  • [8] Comparison of a reusable with a disposable vessel-sealing device in a sheep model: efficacy and costs
    Klar, Maximilian
    Haberstroh, Joerg
    Timme, Sylvia
    Fritzsch, Gernod
    Gitsch, Gerald
    Denschlag, Dominik
    FERTILITY AND STERILITY, 2011, 95 (02) : 795 - 798
  • [9] The Thermal Safety Profile of a New Bipolar Vessel Sealing Device for Thyroid Surgery
    Prasad, Aman
    Smeak, Daniel D.
    Durrant, Jessica
    Newman, Jason G.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 39
  • [10] Laparoscopic sigmoid and rectal resection using an electrothermal bipolar vessel sealing device
    Koessi, Jyrki
    Luostarinen, Markku
    Kontula, Ilpo
    Laato, Matti
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2007, 17 (06): : 719 - 722