Background: A variety of energy-based techniques for arterial and venous vessel ligation have recently been introduced. Using a porcine model we studied the efficacy of the novel reusable BiClamp versus the standard disposable LigaSure bipolar vessel sealing device. We also compared whether arteries respond differently than veins upon sealing. Materials and Methods: In five Swabian Hall pigs, splenectomy and nephrectomy were performed using two different bipolar vessel sealing devices. Measurements of the sealed arteries and veins (diameter 2-7 mm) included rate of seal failure, burst strength, and heat-associated vascular wall morphologic appearance. An additional three animals underwent splenectomy, salpingo-oophorectomy, and small bowel resection, and vessel seals were studied histologically after a seven-day survival period for vessel wall fusion, inflammation, and fibrous organization. Results: Sealing was highly successful, with only one seal failure overall and thus no difference between the two instruments analyzed. The burst pressures of BiClamp-sealed arteries (842 +/- 117 mm Hg) did not differ from that of arteries sealed with LigaSure (856 +/- 102 mm Hg), but were significantly higher than the burst pressures of veins (155 +/- 26 and 216 +/- 71 mm Hg, respectively) (P < 0.05). Independent of the sealing device used, thermal spread was found increased in veins compared to arteries. Histologic analysis after seven days revealed appropriate healing of the vessel wall, including thrombus fibrosis, fibroblast proliferation, and collagen deposition. With both devices, however, the venous but not the arterial walls still presented with massive inflammatory cell infiltrates. Conclusion: Our study indicates that the BiClamp device is as appropriate as the LigaSure instrument to successfully ligate 2-7 mm arteries and veins, demonstrating supraphysiological bursting strengths and adequate lumenal fusion healing. However, veins are more prone to collateral tissue damage and inflammatory wall infiltration.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [31] Use of a Bipolar Vessel-Sealing Device for Splenic Parenchymal Resection in Three Dogs and One Cat
    Siemon, Heather
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2021, 57 (01) : 32 - 36
  • [32] A Prospective Study of In Vivo and Ex Vivo Sealing of the Human Inferior Mesenteric Artery Using an Electrothermal Bipolar Vessel-Sealing Device
    Bibi, Shahida
    Coralic, Jasna
    Velchuru, Vamsi
    Quinteros, Francisco
    Marecik, Slawomir
    Park, John
    Prasad, Leela M.
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2014, 24 (07): : 471 - 474
  • [33] Video-assisted thoracoscopic thoracic duct sealing is inconsistent when performed with a bipolar vessel-sealing device in healthy cats
    Mitchell, Jeffrey W.
    Mayhew, Philipp D.
    Johnson, Eric G.
    Steffey, Michele A.
    Pascoe, Peter J.
    VETERINARY SURGERY, 2018, 47 : O84 - O90
  • [34] Complete resection of the alar folds in eight standing horses with a bipolar dividing and vessel-sealing device
    Kallmyr, Airina
    Giving, Ellen M.
    Moen, Lars O.
    Overlie, Marianne
    Holm, Therese
    David, Florent
    VETERINARY SURGERY, 2020, 49 (03) : 521 - 528
  • [35] Novel hemostatic devices in thyroid surgery: electrothermal bipolar vessel sealing system and harmonic scalpel
    Manouras, Andreas
    Markogiannakis, Haridimos E.
    Kekis, Panagiotis B.
    Lagoudianakis, Emmanuel E.
    Fleming, Bill
    EXPERT REVIEW OF MEDICAL DEVICES, 2008, 5 (04) : 447 - 466
  • [36] Evaluation of a vessel-sealing device for small intestinal resection and anastomosis in normal horses
    Rumbaugh, ML
    Burba, DJ
    Natalini, C
    Hosgood, G
    Moore, RM
    VETERINARY SURGERY, 2003, 32 (06) : 574 - 579
  • [37] A comparison of laparoscopic bipolar vessel sealing devices in the hemostasis of small-, medium-, and large-sized arteries
    Carbonell, AM
    Joels, CS
    Kercher, KW
    Matthews, BD
    Sing, RF
    Heniford, BT
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A, 2003, 13 (06): : 377 - 380
  • [38] A Novel Vascular Anastomotic Coupling Device for End-to-End Anastomosis of Arteries and Veins
    Azapagic, Azur
    Agarwal, Jayant
    Gale, Bruce
    Li, Huizhong
    Nelson, Samuel
    Shea, Jill
    Sant, Himanshu
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (02) : 542 - 552
  • [39] A MICROVASCULAR ANASTOMOTIC DEVICE .1. A HEMODYNAMIC EVALUATION IN RABBIT FEMORAL ARTERIES AND VEINS
    BLAIR, WF
    STEYERS, CM
    BROWN, TD
    GABLE, RH
    MICROSURGERY, 1989, 10 (01) : 21 - 28
  • [40] Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study
    Roberto Campagnacci
    Angelo de Sanctis
    Maddalena Baldarelli
    Massimiliano Rimini
    Giovanni Lezoche
    Mario Guerrieri
    Surgical Endoscopy, 2007, 21 : 1526 - 1531