Differential response of arteries and veins to bipolar vessel sealing: Evaluation of a novel reusable device

被引:57
|
作者
Richter, S
Kollmar, O
Neunhoeffer, E
Schilling, MK
Menger, MD [1 ]
Pistorius, G
机构
[1] Univ Saarland, Inst Clin & Expt Surg, D-66421 Homburg, Germany
[2] Univ Saarland, Dept Gen Visceral Vasc & Pediat Surg, D-6650 Homburg, Germany
[3] Univ Tubingen, Dept Obstet & Gynecol, Tubingen, Germany
关键词
D O I
10.1089/lap.2006.16.149
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: A variety of energy-based techniques for arterial and venous vessel ligation have recently been introduced. Using a porcine model we studied the efficacy of the novel reusable BiClamp versus the standard disposable LigaSure bipolar vessel sealing device. We also compared whether arteries respond differently than veins upon sealing. Materials and Methods: In five Swabian Hall pigs, splenectomy and nephrectomy were performed using two different bipolar vessel sealing devices. Measurements of the sealed arteries and veins (diameter 2-7 mm) included rate of seal failure, burst strength, and heat-associated vascular wall morphologic appearance. An additional three animals underwent splenectomy, salpingo-oophorectomy, and small bowel resection, and vessel seals were studied histologically after a seven-day survival period for vessel wall fusion, inflammation, and fibrous organization. Results: Sealing was highly successful, with only one seal failure overall and thus no difference between the two instruments analyzed. The burst pressures of BiClamp-sealed arteries (842 +/- 117 mm Hg) did not differ from that of arteries sealed with LigaSure (856 +/- 102 mm Hg), but were significantly higher than the burst pressures of veins (155 +/- 26 and 216 +/- 71 mm Hg, respectively) (P < 0.05). Independent of the sealing device used, thermal spread was found increased in veins compared to arteries. Histologic analysis after seven days revealed appropriate healing of the vessel wall, including thrombus fibrosis, fibroblast proliferation, and collagen deposition. With both devices, however, the venous but not the arterial walls still presented with massive inflammatory cell infiltrates. Conclusion: Our study indicates that the BiClamp device is as appropriate as the LigaSure instrument to successfully ligate 2-7 mm arteries and veins, demonstrating supraphysiological bursting strengths and adequate lumenal fusion healing. However, veins are more prone to collateral tissue damage and inflammatory wall infiltration.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [21] Efficacy and quality of vessel sealing - Comparison of a reusable with a disposable device and effects of clamp surface geometry and structure
    Richter, S
    Kollmar, O
    Schilling, MK
    Pistorius, GA
    Menger, MD
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (06): : 890 - 894
  • [22] EVALUATION OF ENSEAL®, AN ADAPTIVE BIPOLAR ELECTROSURGICAL TISSUE-SEALING DEVICE
    Dunay, Miklos Pal
    Jakab, Csaba
    Nemeth, Tibor
    ACTA VETERINARIA HUNGARICA, 2012, 60 (01) : 27 - 40
  • [23] Partial pancreatectomy and splenectomy using a bipolar vessel sealing device in a cat with an anaplastic pancreatic carcinoma
    Knell, S. C.
    Venzin, C.
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 2012, 154 (07): : 298 - 301
  • [24] Cordless ultrasonic dissector versus advanced bipolar vessel sealing device for laparoscopic ovariectomy in dogs
    Spillebeen, Anneleen L.
    Janssens, Sara S. D. S.
    Thomas, Rachel E.
    Kirpensteijn, Jolle
    van Nimwegen, Sebastiaan A.
    VETERINARY SURGERY, 2017, 46 (04) : 467 - 477
  • [25] Safety and efficacy of an electrothermal bipolar vessel sealing device in sealing and division of the inferior mesenteric vessels in minimally invasive colorectal surgery
    A. Pai
    J. Sugrue
    S. Bibi
    G. Melich
    S. Marecik
    L. M. Prasad
    J. Park
    Techniques in Coloproctology, 2016, 20 : 505 - 506
  • [26] Safety and efficacy of an electrothermal bipolar vessel sealing device in sealing and division of the inferior mesenteric vessels in minimally invasive colorectal surgery
    Pai, A.
    Sugrue, J.
    Bibi, S.
    Melich, G.
    Marecik, S.
    Prasad, L. M.
    Park, J.
    TECHNIQUES IN COLOPROCTOLOGY, 2016, 20 (07) : 505 - 506
  • [27] Response to Gizzo et al.: Electrosurgical bipolar vessel sealing for vaginal hysterectomies
    Vasileios Pergialiotis
    Dimitrios-Efthymios Vlachos
    Archives of Gynecology and Obstetrics, 2014, 290 : 1047 - 1047
  • [28] Response to Gizzo et al.: Electrosurgical bipolar vessel sealing for vaginal hysterectomies
    Pergialiotis, Vasileios
    Vlachos, Dimitrios-Efthymios
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2014, 290 (06) : 1047 - 1047
  • [29] Evaluation of a vessel-sealing device to assist eye enucleation and exenteration in the horse
    Launois, M. T.
    Vandeweerd, J. M. E. F.
    Perrin, R. A. R.
    Brogniez, L.
    Gabriel, A.
    Coomer, R.
    Clegg, P. D.
    Desbrosse, A. M.
    Desbrosse, F. G.
    EQUINE VETERINARY EDUCATION, 2009, 21 (11) : 596 - 601
  • [30] A new bipolar device for sealing and cutting: ex and in vivo studies for performance evaluation
    Thiel, Christian
    Frericks, Luca T.
    Schenk, Martin
    Koenigsrainer, Alfred
    Brucker, Sara Y.
    Kraemer, Bernhard
    Steger, Volker
    Biber, Ulrich
    Linzenbold, Walter
    Enderle, Markus D.
    Thiel, Karolin
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2022, 31 (08) : 1131 - 1139