Differential response of arteries and veins to bipolar vessel sealing: Evaluation of a novel reusable device

被引:57
|
作者
Richter, S
Kollmar, O
Neunhoeffer, E
Schilling, MK
Menger, MD [1 ]
Pistorius, G
机构
[1] Univ Saarland, Inst Clin & Expt Surg, D-66421 Homburg, Germany
[2] Univ Saarland, Dept Gen Visceral Vasc & Pediat Surg, D-6650 Homburg, Germany
[3] Univ Tubingen, Dept Obstet & Gynecol, Tubingen, Germany
关键词
D O I
10.1089/lap.2006.16.149
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: A variety of energy-based techniques for arterial and venous vessel ligation have recently been introduced. Using a porcine model we studied the efficacy of the novel reusable BiClamp versus the standard disposable LigaSure bipolar vessel sealing device. We also compared whether arteries respond differently than veins upon sealing. Materials and Methods: In five Swabian Hall pigs, splenectomy and nephrectomy were performed using two different bipolar vessel sealing devices. Measurements of the sealed arteries and veins (diameter 2-7 mm) included rate of seal failure, burst strength, and heat-associated vascular wall morphologic appearance. An additional three animals underwent splenectomy, salpingo-oophorectomy, and small bowel resection, and vessel seals were studied histologically after a seven-day survival period for vessel wall fusion, inflammation, and fibrous organization. Results: Sealing was highly successful, with only one seal failure overall and thus no difference between the two instruments analyzed. The burst pressures of BiClamp-sealed arteries (842 +/- 117 mm Hg) did not differ from that of arteries sealed with LigaSure (856 +/- 102 mm Hg), but were significantly higher than the burst pressures of veins (155 +/- 26 and 216 +/- 71 mm Hg, respectively) (P < 0.05). Independent of the sealing device used, thermal spread was found increased in veins compared to arteries. Histologic analysis after seven days revealed appropriate healing of the vessel wall, including thrombus fibrosis, fibroblast proliferation, and collagen deposition. With both devices, however, the venous but not the arterial walls still presented with massive inflammatory cell infiltrates. Conclusion: Our study indicates that the BiClamp device is as appropriate as the LigaSure instrument to successfully ligate 2-7 mm arteries and veins, demonstrating supraphysiological bursting strengths and adequate lumenal fusion healing. However, veins are more prone to collateral tissue damage and inflammatory wall infiltration.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [41] Influence of multiple reuse and resterilization cycles on the performance of a bipolar vessel sealing device (LigaSure) intended for single use
    Kuvaldina, Alexandra
    Hayes, Galina
    Sumner, Julia
    Behling-Kelly, Erica
    VETERINARY SURGERY, 2018, 47 (07) : 951 - 957
  • [42] Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study
    Campagnacci, Roberto
    de Sanctis, Angelo
    Baldarelli, Maddalena
    Rimini, Massimiliano
    Lezoche, Giovanni
    Guerrieri, Mario
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2007, 21 (09): : 1526 - 1531
  • [43] Safety and effectiveness of a novel generator algorithm for bipolar vessel sealing: a randomised controlled chronic animal study
    Bernhard Kraemer
    Christos Tsaousidis
    Stephan Kruck
    Martin Schenk
    Marcus Scharpf
    Stefan Kommoss
    Sara Brucker
    Daniela Nuessle
    Markus D. Enderle
    Ulrich Biber
    BMC Surgery, 19
  • [44] Safety and effectiveness of a novel generator algorithm for bipolar vessel sealing: a randomised controlled chronic animal study
    Kraemer, Bernhard
    Tsaousidis, Christos
    Kruck, Stephan
    Schenk, Martin
    Scharpf, Marcus
    Kommoss, Stefan
    Brucker, Sara
    Nuessle, Daniela
    Enderle, Markus D.
    Biber, Ulrich
    BMC SURGERY, 2019, 19 (01)
  • [45] Novel use of LigaSure Impact™ electrosurgical bipolar vessel sealing system in skin-sparing mastectomy
    Miyagi, K.
    Rossi, S. H.
    Malata, C. M.
    Forouhi, P.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2015, 68 (06): : E126 - E128
  • [46] Evaluation of a vessel-sealing device for laparoscopic granulosa cell tumor removal in standing mares
    Hubert, JD
    Burba, DJ
    Moore, RM
    VETERINARY SURGERY, 2006, 35 (04) : 324 - 329
  • [47] Bipolar Sealing Device Use in Pancreas Graft Preparation: A Novel Tieless Backtable Surgery Technique
    Martins, Paulo N.
    Gillooly, Andrew R.
    Movahedi, Babak
    Bozorgzadeh, Adel
    TRANSPLANTATION DIRECT, 2018, 4 (10):
  • [48] Validation of a Laparoscopic Ferromagnetic Technology-based Vessel Sealing Device and Comparative Study to Ultrasonic and Bipolar Laparoscopic Devices
    Chen, Jennwood
    Jensen, Curtis R.
    Manwaring, Preston K.
    Glasgow, Robert E.
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2017, 27 (02): : E12 - E17
  • [49] Is advanced bipolar vessel sealing device really effective in decreasing the pelvic lymphocele ratio in open surgery for endometrial cancer?
    Narin, Mehmet Ali
    Bas, Sevda
    Seyfettinoglu, Sevtap
    Yar, Tuba
    Narin, Raziye
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2023, 53 (01) : 68 - 76
  • [50] Comparative analysis between a bipolar vessel sealing and cutting device and the tie and suture technique in thyroidectomy: A randomized clinical trial
    Veronica Chavez, K.
    Barajas, Manuel
    Ramirez, Jaqueline
    Pablo Pantoja, Juan
    Sierra, Mauricio
    Velazquez-Fernandez, David
    Herrera, Miguel F.
    SURGERY, 2017, 161 (02) : 477 - 484