Use of a bipolar vessel sealing device in canine orchiectomy

被引:0
|
作者
Yaman, Ceren [1 ]
Kanca, Halit [2 ]
机构
[1] Ankara Univ, Grad Sch Hlth Sci, Ankara, Turkiye
[2] Ankara Univ, Fac Vet Med, Dept Obstet & Gynecol, Ankara, Turkiye
来源
关键词
Bipolar vessel sealing; Canine; Orchiectomy; Postoperative complication; Postoperative pain; POSTOPERATIVE COMPLICATIONS; THERMAL SPREAD; MALE DOGS; OVARIOHYSTERECTOMY; CASTRATION; CATS; LIGASURE(TM); GONADECTOMY; OVARIECTOMY; HEMOSTASIS;
D O I
10.33988/auvfd.1092062
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Bipolar vessel sealing (BVS) devices are being used increasingly in veterinary medicine. The objective was to determine whether the use of a BVS device in prescrotal open orchiectomy of dogs reduced surgical time, postoperative pain and surgical site complications compared to ligation with suture. Fifty medium to large breed dogs admitted for elective castration were randomly assigned to either the ligation or BVS groups. Duration of surgery, pain score at postoperative 15 minutes, 1, 2, and 24 hours, and surgical site swelling and bruising scores at 24 hours were compared. Duration of surgery was shorter (P<0.001) in the BSV group (median 8.30; range 7.03 to 10.17 minutes) than the ligation group (median 10.18; range 7.47 to 12.33 minutes). There was a significant effect of age (r=0.458, P=0.021) and body weight (r=0.432, P=0.031) of the animal on the duration of surgery in the BVS group. Lower pain scores were observed in the BVS group at postoperative 15 minutes (P=0.001) and 1 hour (P=0.045). Pain scores were not different between groups at 2 hours and 24 hours (P>0.05). The surgical site swelling score was lower (P=0.034) in the BVS group (0.24 +/- 0.09) compared to the ligation group (0.72 +/- 0.17). A lower bruising score (P=0.015) was observed in the BVS group (0.44 +/- 0.13) than in the ligation group (1.16 +/- 0.22). The use of BVS method was associated with significantly shorter surgery times and lower postoperative pain and surgical site complications than traditional ligation technique in canine open orchiectomy.
引用
收藏
页码:375 / 382
页数:8
相关论文
共 50 条
  • [1] Use of a bipolar vessel sealing device in canine orchiectomy
    Kanca, Halit
    Yaman, Ceren
    REPRODUCTION IN DOMESTIC ANIMALS, 2022, 57 : 48 - 48
  • [2] Use of a bipolar vessel-sealing device in resection of canine insulinoma
    Wouters, E. G. H.
    Buishand, F. O.
    Kik, M.
    Kirpensteijn, J.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2011, 52 (03) : 139 - 145
  • [3] Canine orchiectomy via scrotal approach using vessel-sealing device: prospective observational study of 200 cases
    Yiapanis, C.
    Ober, C.
    Psyllaki, M.
    Attipa, C.
    Potamopoulou, M.
    Vasilakis, T.
    Milram, J.
    JOURNAL OF THE HELLENIC VETERINARY MEDICAL SOCIETY, 2024, 75 (01): : 6831 - 6838
  • [4] Use of a bipolar vessel-sealing device for parenchymal transection during liver surgery
    Strasberg, SM
    Drebin, JA
    Linehan, D
    JOURNAL OF GASTROINTESTINAL SURGERY, 2002, 6 (04) : 569 - 574
  • [5] Use of a bipolar vessel-sealing device for parenchymal transection during liver surgery
    Steven M. Strasberg
    Jeffrey A. Drebin
    David Line Han
    Journal of Gastrointestinal Surgery, 2002, 6 : 569 - 574
  • [6] Use of an Electrothermal Bipolar Vessel Sealing Device During Recipient Hepatectomy for Liver Transplantation
    Houben, Philipp
    Buechler, Markus W.
    Schemmer, Peter
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2014, 219 (05) : E59 - E63
  • [7] Orchiectomy and scrotal ablation using a bipolar electrothermal sealing device in macropods: Four cases
    Diaz-Portalatin, Noah
    Sadar, Miranda J.
    Anderson, Kailey
    Brandao, Joao
    JOURNAL OF EXOTIC PET MEDICINE, 2023, 47 : 34 - 38
  • [8] Effect of multiple use and sterilization on sealing performance of bipolar vessel sealing devices
    Gardeweg, Silvia
    Bockstahler, Barbara
    Dupre, Gilles
    PLOS ONE, 2019, 14 (08):
  • [9] Heat Transfer Simulation for Design of Electrothermal Bipolar Vessel Sealing Device
    Kim, Seongjun
    Choi, Jaesoon
    2015 15TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2015, : 1853 - 1856
  • [10] Bipolar Electrosurgical Vessel-Sealing Device With Compressive Force Monitoring
    Chen, Roland K.
    Chastagner, Matthew W.
    Geiger, James D.
    Shih, Albert J.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (06):