Laparoscopic sigmoid and rectal resection using an electrothermal bipolar vessel sealing device

被引:13
|
作者
Koessi, Jyrki [1 ]
Luostarinen, Markku [1 ]
Kontula, Ilpo [2 ]
Laato, Matti [3 ]
机构
[1] Paijat Hame Cent Hosp, Dept Surg, Lahti 15850, Finland
[2] Kuusankoski Dist Hosp, Dept Surg, Kuusankoshi, Finland
[3] Univ Turku, Dept Surg, Turku, Finland
关键词
D O I
10.1089/lap.2006.0238
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Laparoscopic colonic resection has gained popularity as a method to treat colonic diseases. The electrothermal bipolar vessel sealer (EBVS; LigaSure Atlas (R) ) is a modern device that allows the secure sealing of vessels with a diameter of up to 7 mm. The aim of the present study was to evaluate the suitability of the device for laparoscopic colonic surgery. Methods: The immediate outcome of 114 consecutive patients who underwent a sigmoid or rectal resection was prospectively analyzed. The intention was to perform all operations with the EBVS for dissection and ligation of the mesenterial vessels. Details on patient characteristics, peroperative and postoperative complications, and postoperative recovery were recorded prospectively and analyzed. Results: One hundred and fourteen patients were scheduled for elective left-sided colonic or rectal resection. Massive intra-abdominal adhesions in 1 patient required a conversion of the laparoscopic procedure to an open one; In total, 113 laparoscopic operations were thus performed. The mean operative time was 87.7 +/- 2.8 minutes, and the mean time for patients to tolerate solid food was 3.4 +/- 0.1 days and the time to discharge from hospital was 4.6 +/- 0.2 days. There were nine (8.0%) general complications, and additionally, 10.6% of patients suffered from surgical complications. Conclusions: The electrothermal bipolar vessel sealer is suitable and safe for laparoscopic sigmoid and rectal resections. The use of the device probably reduces the operative time.
引用
收藏
页码:719 / 722
页数:4
相关论文
共 50 条
  • [1] Laparoscopic liver resection using a bipolar vessel-sealing device: LigaSure®
    Slakey, Douglas P.
    HPB, 2008, 10 (04) : 253 - 255
  • [2] Heat Transfer Simulation for Design of Electrothermal Bipolar Vessel Sealing Device
    Kim, Seongjun
    Choi, Jaesoon
    2015 15TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2015, : 1853 - 1856
  • [3] Use of an electrothermal bipolar sealing device in ligation of major mesenteric vessels during laparoscopic colorectal resection
    Martin, S. T.
    Heeney, A.
    Pierce, C.
    O'Connell, P. R.
    Hyland, J. M.
    Winter, Desmond C.
    TECHNIQUES IN COLOPROCTOLOGY, 2011, 15 (03) : 285 - 289
  • [4] Use of an electrothermal bipolar sealing device in ligation of major mesenteric vessels during laparoscopic colorectal resection
    S. T. Martin
    A. Heeney
    C. Pierce
    P. R. O’Connell
    J. M. Hyland
    Desmond C. Winter
    Techniques in Coloproctology, 2011, 15 : 285 - 289
  • [5] 'Use of electrothermal vessel sealing with LigaSure™ device during laparoscopic splenectomy'
    Barbaros, U.
    Dinccag, A.
    Deveci, U.
    Akyuz, M.
    Tukenmez, M.
    Erbil, Y.
    Mercan, S.
    ACTA CHIRURGICA BELGICA, 2007, 107 (02) : 162 - 165
  • [6] Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study
    Roberto Campagnacci
    Angelo de Sanctis
    Maddalena Baldarelli
    Massimiliano Rimini
    Giovanni Lezoche
    Mario Guerrieri
    Surgical Endoscopy, 2007, 21 : 1526 - 1531
  • [7] Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study
    Campagnacci, Roberto
    de Sanctis, Angelo
    Baldarelli, Maddalena
    Rimini, Massimiliano
    Lezoche, Giovanni
    Guerrieri, Mario
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2007, 21 (09): : 1526 - 1531
  • [8] Prevention of lymphocele development in gynecologic cancers by the electrothermal bipolar vessel sealing device
    Tsuda, Naotake
    Ushijima, Kimio
    Kawano, Kouichiro
    Takemoto, Shuji
    Nishio, Shin
    Sonoda, Gounosuke
    Kamura, Toshiharu
    JOURNAL OF GYNECOLOGIC ONCOLOGY, 2014, 25 (03) : 229 - 235
  • [9] Electrothermal bipolar vessel sealing device (LigaSure™) versus conventional diathermy in laparoscopic myomectomy: A propensity-matched analysis
    Li, Yi-Chieh
    Chao, Angel
    Yang, Lan-Yang
    Huang, Hui-Yu
    Huang, Yi-Ting
    Kuo, Hsin-Hong
    Wang, Chin-Jung
    PLOS ONE, 2018, 13 (03):
  • [10] Sutureless open low anterior resection with total mesorectal excision for rectal cancer with the use of the electrothermal bipolar vessel sealing system
    Manouras, Andreas
    Filippakis, George M.
    Tsekouras, Dimitrios
    Lagoudianakis, Emmanuel
    Genetzakis, Michael
    Markogiannakis, Haridimos
    Kafiri, Georgia
    Pararas, Nikolaos
    Papanikolaou, Dimitrios
    Toutouzas, Konstantinos G.
    Katsaragakis, Stilianos
    MEDICAL SCIENCE MONITOR, 2007, 13 (05): : CR224 - CR230