Feasibility of using an intraoral scanner for a complete-arch digital scan

被引:83
|
作者
Park, Gun-Hong [1 ]
Son, KeunBaDa [2 ]
Lee, Kyu-Bok [3 ]
机构
[1] Kyungpook Natl Univ, Grad Sch, Dept Dent, Daegu, South Korea
[2] Kyungpook Natl Univ, Grad Sch, Dept Dent Sci, Daegu, South Korea
[3] Kyungpook Natl Univ, Sch Dent, Dept Prosthodonl, Daegu, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 121卷 / 05期
关键词
COMPUTER-AIDED ANALYSIS; DENTAL IMPRESSIONS; IMPLANT IMPRESSIONS; IN-VITRO; ACCURACY; PRECISION; MODELS; REPRODUCIBILITY; RELIABILITY; INSPECTION;
D O I
10.1016/j.prosdent.2018.07.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The introduction of intraoral scanners has increased the use of digital technology in dental procedures. However, research on the extent of clinically recommended scans is lacking. Purpose. The purpose of this in vitro study was to compare 3D arch distortion according to the distance from the tooth at the beginning of a complete-arch scan made using an intraoral scanner. Material and methods. An industrial scanner was used to digitize a master model for a computer-aided design (CAD) reference model. In addition, the master model was digitized using 4 intraoral scanners (TRIOS2, TRIOS3, CS3500, and CS3600) and 1 dental laboratory scanner (FREEDOM HD) to make the CAD test model (N=20). The scanned teeth were divided using an inspection software program (Geomagic control X), and overlapping and 3D analyses of the CAD reference model and CAD test model were performed. The presence or absence of normal distribution in the root mean square (RMS) values of all divided teeth was assessed and evaluated with the Kruskal-Wallis test (alpha=.05), and post hoc comparison was performed using the Mann-Whitney U-test and Bonferroni correction method (alpha=.005). Results. The overall RMS value was significantly different for all scanners (P<.001). The dental laboratory scanner showed the lowest value (47.5 +/- 1.6 mu m), whereas TRIOS2 showed the highest value (343.4 +/- 56.4 mu m). TRIOS3 (9.6 +/- 1.2 mu m) showed the best trueness in those teeth where the scan started. However, the larger the scan range, the lower the RMS value difference between TRIOS3 and CS3500. The RMS values of the dental laboratory scanners were higher than those of the intraoral scanners in the narrow scan range. CS3600 showed an RMS value less than or equal to that of the dental laboratory scanner at 5 teeth scan ranges. However, the wider the scan range, the lower the RMS values of all the intraoral scanners. Conclusions. Current complete-arch scanning is not sufficiently accurate for fabricating fixed prostheses. However, intraoral scanners are useful for short scans, such as those for single (TRIOS2, TRIOS3, and CS3500) or short-span prostheses (CS3600).
引用
收藏
页码:803 / 810
页数:8
相关论文
共 50 条
  • [31] Accuracy of intraoral scanners in different complete arch scan patterns
    Pattamavilai, Sakaorat
    Ongthiemsak, Chakree
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 155 - 162
  • [32] Evaluation of the trueness and precision of complete arch digital impressions on a human maxilla using seven different intraoral digital impression systems and a laboratory scanner
    Mennito, Anthony S.
    Evans, Zachary P.
    Nash, Jansen
    Bocklet, Christopher
    Lauer , Abigail
    Bacro, Thierry
    Cayouette, Monica
    Ludlow, Mark
    Renne, Walter G.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (04) : 369 - 377
  • [33] Accuracy of Complete-Arch Implant Digital Scans: Effect of Scanning Protocol, Number of Implants, and Scan Body Splinting
    Denneulin, Thomas
    Rignon-Bret, Christophe
    Ravalec, Guy
    Tapie, Laurent
    Bouter, Denis
    Wulfman, Claudine
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (02) : 219 - 227
  • [34] Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner
    Mueller, Philipp
    Ender, Andreas
    Joda, Tim
    Katsoulis, Joannis
    QUINTESSENCE INTERNATIONAL, 2016, 47 (04): : 343 - 349
  • [35] In Vitro Trueness and Precision of Intraoral Scanners in a Four-Implant Complete-Arch Model
    Spagopoulos, Dimitrios
    Kaisarlis, George
    Spagopoulou, Foteini
    Halazonetis, Demetrios J. J.
    Gueth, Jan-Frederik
    Papazoglou, Efstratios
    DENTISTRY JOURNAL, 2023, 11 (01)
  • [36] Accuracy of 9 intraoral scanners for complete-arch image acquisition: A qualitative and quantitative evaluation
    Kim, Ryan Jin-Young
    Park, Ji-Man
    Shim, June-Sung
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (06): : 895 - +
  • [37] Complete-arch accuracy of seven intraoral scanners measured by the virtual-fit method
    Borbola, Daniel
    Mikolicz, Akos
    Romanszky, Laszlo
    Sersli, Gyorgy
    DeFee, Michael
    Renne, Walter
    Vag, Janos
    JOURNAL OF DENTISTRY, 2024, 149
  • [38] Accuracy of Different Complete-Arch Digital Scanning Techniques with a Combined Healing Abutment-Scan Body System
    Cakmak, Gulce
    Yilmaz, Hakan
    Trevino Santos, Alejandro
    Kokat, Ali Murat
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 67 - 75
  • [39] Enhancing intraoral scanner accuracy using scan aid for multiple implants in the edentulous arch: An in vivo study
    Kernen, Florian
    Braendle, Dominik
    Wagendorf, Oliver
    Recca, Mario
    Mehrhof, Juergen
    Vach, Kirstin
    Nahles, Susanne
    Nelson, Katja
    Fluegge, Tabea
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (08) : 793 - 801
  • [40] Fit of complete-arch implant-supported prostheses produced from an intraoral scan by using an auxiliary device and from an elastomeric impression: A pilot clinical trial
    Roig, Elena
    Roig, Miguel
    Garza, Luis Carlos
    Costa, Santiago
    Maia, Paulo
    Espona, Jose
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 404 - 414