Feasibility of using an intraoral scanner for a complete-arch digital scan

被引:83
|
作者
Park, Gun-Hong [1 ]
Son, KeunBaDa [2 ]
Lee, Kyu-Bok [3 ]
机构
[1] Kyungpook Natl Univ, Grad Sch, Dept Dent, Daegu, South Korea
[2] Kyungpook Natl Univ, Grad Sch, Dept Dent Sci, Daegu, South Korea
[3] Kyungpook Natl Univ, Sch Dent, Dept Prosthodonl, Daegu, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 121卷 / 05期
关键词
COMPUTER-AIDED ANALYSIS; DENTAL IMPRESSIONS; IMPLANT IMPRESSIONS; IN-VITRO; ACCURACY; PRECISION; MODELS; REPRODUCIBILITY; RELIABILITY; INSPECTION;
D O I
10.1016/j.prosdent.2018.07.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The introduction of intraoral scanners has increased the use of digital technology in dental procedures. However, research on the extent of clinically recommended scans is lacking. Purpose. The purpose of this in vitro study was to compare 3D arch distortion according to the distance from the tooth at the beginning of a complete-arch scan made using an intraoral scanner. Material and methods. An industrial scanner was used to digitize a master model for a computer-aided design (CAD) reference model. In addition, the master model was digitized using 4 intraoral scanners (TRIOS2, TRIOS3, CS3500, and CS3600) and 1 dental laboratory scanner (FREEDOM HD) to make the CAD test model (N=20). The scanned teeth were divided using an inspection software program (Geomagic control X), and overlapping and 3D analyses of the CAD reference model and CAD test model were performed. The presence or absence of normal distribution in the root mean square (RMS) values of all divided teeth was assessed and evaluated with the Kruskal-Wallis test (alpha=.05), and post hoc comparison was performed using the Mann-Whitney U-test and Bonferroni correction method (alpha=.005). Results. The overall RMS value was significantly different for all scanners (P<.001). The dental laboratory scanner showed the lowest value (47.5 +/- 1.6 mu m), whereas TRIOS2 showed the highest value (343.4 +/- 56.4 mu m). TRIOS3 (9.6 +/- 1.2 mu m) showed the best trueness in those teeth where the scan started. However, the larger the scan range, the lower the RMS value difference between TRIOS3 and CS3500. The RMS values of the dental laboratory scanners were higher than those of the intraoral scanners in the narrow scan range. CS3600 showed an RMS value less than or equal to that of the dental laboratory scanner at 5 teeth scan ranges. However, the wider the scan range, the lower the RMS values of all the intraoral scanners. Conclusions. Current complete-arch scanning is not sufficiently accurate for fabricating fixed prostheses. However, intraoral scanners are useful for short scans, such as those for single (TRIOS2, TRIOS3, and CS3500) or short-span prostheses (CS3600).
引用
收藏
页码:803 / 810
页数:8
相关论文
共 50 条
  • [41] Modified Complete-Arch Impression Technique for Facilitating Esthetic and Biomechanical Precision in Complete-Arch Rehabilitation
    Mizrahi, Basil
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (06): : 474 - 487
  • [42] Evaluation of laboratory scanner accuracy by a novel calibration block for complete-arch implant rehabilitation
    Pan, Yu
    Tam, Juliana M. Y.
    Tsoi, James K. H.
    Lam, Walter Y. H.
    Huang, Ruoxuan
    Chen, Zhuofan
    Pow, Edmond H. N.
    JOURNAL OF DENTISTRY, 2020, 102
  • [43] Effect of novel prefabricated auxiliary devices attaching to scan bodies on the accuracy of intraoral scanning of complete-arch with multiple implants: An in-vitro study
    Wu, Hio Kuan
    Wang, Jing
    Chen, Guanhui
    Huang, Xiaoqiong
    Deng, Feilong
    Li, Yiming
    JOURNAL OF DENTISTRY, 2023, 138
  • [44] Complete digital workflow in prosthesis prototype fabrication for complete-arch implant rehabilitation: A technique
    Papaspyridakos, Panos
    Chen, Yo-wei
    Gonzalez-Gusmao, Ilenia
    Att, Wael
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (03): : 189 - 192
  • [45] Accuracy of intraoral scan with prefabricated aids and stereophotogrammetry compared with open tray impressions for complete-arch implant-supported prosthesis: A clinical study
    Fu, Xiao-Jiao
    Liu, Min
    Liu, Bei-Lei
    Tonetti, Maurizio S.
    Shi, Jun-Yu
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 830 - 840
  • [46] Effect of simulated intraoral variables on the accuracy of a photogrammetric imaging technique for complete-arch implant prostheses
    Bratos, Manuel
    Bergin, Jumping M.
    Rubenstein, Jeffrey E.
    Sorensen, John A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02): : 232 - 241
  • [47] Using an existing digital surgical guide and used burs as aids for a complete-arch implant impression
    Rong, Rong
    Lin, Ting-Yun
    Sa, Yue
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (04): : 664 - 666
  • [48] Comparison of Different Intraoral Scanners With Prefabricated Aid on Accuracy and Framework Passive Fit of Digital Complete-Arch Implant Impression: An In Vitro Study
    Fu, Xiao-Jiao
    Liu, Min
    Shi, Jun-Yu
    Deng, Ke
    Lai, Hong-Chang
    Gu, Wen
    Zhang, Xiao-Meng
    CLINICAL ORAL IMPLANTS RESEARCH, 2024,
  • [49] Effect of splinting scan bodies on the trueness of complete arch digital implant scans with 5 different intraoral scanners
    Azevedo, Luis
    Marques, Tiago
    Karasan, Duygu
    Fehmer, Vincent
    Sailer, Irena
    Correia, Andre
    Gomez-Polo, Miguel
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 204 - 210
  • [50] Combined use of a facial scanner and an intraoral scanner to acquire a digital scan for the fabrication of an orbital prosthesis
    Liu, Huan
    Bai, Shizhu
    Yu, Xiaonan
    Zhao, Yimin
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03): : 531 - 534