Feasibility of using an intraoral scanner for a complete-arch digital scan

被引:83
|
作者
Park, Gun-Hong [1 ]
Son, KeunBaDa [2 ]
Lee, Kyu-Bok [3 ]
机构
[1] Kyungpook Natl Univ, Grad Sch, Dept Dent, Daegu, South Korea
[2] Kyungpook Natl Univ, Grad Sch, Dept Dent Sci, Daegu, South Korea
[3] Kyungpook Natl Univ, Sch Dent, Dept Prosthodonl, Daegu, South Korea
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 121卷 / 05期
关键词
COMPUTER-AIDED ANALYSIS; DENTAL IMPRESSIONS; IMPLANT IMPRESSIONS; IN-VITRO; ACCURACY; PRECISION; MODELS; REPRODUCIBILITY; RELIABILITY; INSPECTION;
D O I
10.1016/j.prosdent.2018.07.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The introduction of intraoral scanners has increased the use of digital technology in dental procedures. However, research on the extent of clinically recommended scans is lacking. Purpose. The purpose of this in vitro study was to compare 3D arch distortion according to the distance from the tooth at the beginning of a complete-arch scan made using an intraoral scanner. Material and methods. An industrial scanner was used to digitize a master model for a computer-aided design (CAD) reference model. In addition, the master model was digitized using 4 intraoral scanners (TRIOS2, TRIOS3, CS3500, and CS3600) and 1 dental laboratory scanner (FREEDOM HD) to make the CAD test model (N=20). The scanned teeth were divided using an inspection software program (Geomagic control X), and overlapping and 3D analyses of the CAD reference model and CAD test model were performed. The presence or absence of normal distribution in the root mean square (RMS) values of all divided teeth was assessed and evaluated with the Kruskal-Wallis test (alpha=.05), and post hoc comparison was performed using the Mann-Whitney U-test and Bonferroni correction method (alpha=.005). Results. The overall RMS value was significantly different for all scanners (P<.001). The dental laboratory scanner showed the lowest value (47.5 +/- 1.6 mu m), whereas TRIOS2 showed the highest value (343.4 +/- 56.4 mu m). TRIOS3 (9.6 +/- 1.2 mu m) showed the best trueness in those teeth where the scan started. However, the larger the scan range, the lower the RMS value difference between TRIOS3 and CS3500. The RMS values of the dental laboratory scanners were higher than those of the intraoral scanners in the narrow scan range. CS3600 showed an RMS value less than or equal to that of the dental laboratory scanner at 5 teeth scan ranges. However, the wider the scan range, the lower the RMS values of all the intraoral scanners. Conclusions. Current complete-arch scanning is not sufficiently accurate for fabricating fixed prostheses. However, intraoral scanners are useful for short scans, such as those for single (TRIOS2, TRIOS3, and CS3500) or short-span prostheses (CS3600).
引用
收藏
页码:803 / 810
页数:8
相关论文
共 50 条
  • [21] Obtaining reliable intraoral digital scans for an implant-supported complete-arch prosthesis: A dental technique
    Iturrate, Mikel
    Minguez, Rikardo
    Pradies, Guillermo
    Solaberrieta, Eneko
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (02): : 237 - 241
  • [22] Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study
    Pozzi, Alessandro
    Carosi, Paolo
    Gallucci, German O.
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (10) : 1106 - 1117
  • [23] TRUENESS EVALUATION OF LATEST GENERATION OF INTRAORAL SCANNERS ON COMPLETE-ARCH IMPLANT IMPRESSIONS
    Issever, Dilara Seyma Alpkilic
    Deger, Sabire isler
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (04) : e1 - e12
  • [24] Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses
    Mizumoto, Ryan M.
    Yilmaz, Burak
    McGlumphy, Edwin A., Jr.
    Seidt, Jeremy
    Johnston, William M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 96 - 104
  • [25] Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete-arch intraoral digital implant scans
    Gomez-Polo, Miguel
    Cascos, Rocio
    Ortega, Rocio
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (06) : 591 - 601
  • [26] Maxillary and mandibular complete-arch implant rehabilitation using a complete digital workflow: A case report
    Ahmed, Walaa Magdy
    Alhazmi, Ahlam
    Alharbi, Mazin Talal
    Azhari, Amr Ahmed
    Alqarni, Hatem
    Shaheen, Hesham F.
    Mitwalli, Ehab Tawfiq
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (08): : 662 - 668
  • [27] Reverse scan body: The scan pattern affects the fit of complete-arch prototype prostheses
    Papaspyridakos, Panos
    Bedrossian, E. Armand
    Ntovas, Panagiotis
    Kudara, Yukio
    Bokhary, Abdullah
    Chochlidakis, Konstantinos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 : 186 - 191
  • [28] Single-arch digital removable complete denture: A workflow that starts from the intraoral scan
    Lo Russo, Lucio
    Salamini, Angelo
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (01): : 20 - 24
  • [29] Effect of scan powder and scanning technology on measured deviations of complete-arch implant supported frameworks digitized with industrial and intraoral scanners
    Donmez, Mustafa Borga
    Cakmak, Gulce
    Dede, Dogu Omur
    Kucukekenci, Ahmet Serkan
    Lu, Wei-En
    Schumacher, Fernanda Lang
    Revilla-Leon, Marta
    Yilmaz, Burak
    JOURNAL OF DENTISTRY, 2023, 138
  • [30] Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study
    Meneghetti, Priscila Ceolin
    Li, Junying
    Borella, Paulo Sergio
    Mendonca, Gustavo
    Burnett Jr, Luiz Henrique
    PLOS ONE, 2023, 18 (12):