Fit of complete-arch implant-supported prostheses produced from an intraoral scan by using an auxiliary device and from an elastomeric impression: A pilot clinical trial

被引:18
|
作者
Roig, Elena [1 ]
Roig, Miguel [1 ]
Garza, Luis Carlos [1 ]
Costa, Santiago [1 ]
Maia, Paulo [2 ]
Espona, Jose [1 ,3 ]
机构
[1] Univ Int Catalunya, Dept Restorat Dent, Barcelona, Spain
[2] Inst Super Ciencias Saude Egas Moniz, Dept Oral Surg, Capar, Caparica, Portugal
[3] Univ Int Catalunya, Carrer Pedro & Pons 1, Catalunya 08190, Spain
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 128卷 / 03期
关键词
3-DIMENSIONAL ACCURACY; CONVENTIONAL IMPRESSIONS; FIXED PROSTHODONTICS; FRAMEWORK; MISFIT; PRECISION;
D O I
10.1016/j.prosdent.2020.10.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The accuracy of impressions for implant-supported prostheses is essential to ensure a passive fit of the definitive prosthesis. Intraoral scanners (IOSs) have been developed as an alternative to complete-arch implant-supported restorations; however, whether they are sufficiently accurate when more than 3 nonaligned implants are involved is unclear.Purpose. The purpose of this pilot clinical study was to determine whether the fit of complete-arch zirconia implant-supported frameworks processed on a cast obtained with an IOS and adjusted with an auxiliary device is equivalent to a prosthesis obtained from an elastomeric impression.Material and methods. Twelve consecutive participants who were ready for complete-arch restorations on already osseointegrated implants were enrolled. Two records were made, one open-tray with polyether and splinted impression copings and the second with an IOS. A verification gypsum device was used for the elastomeric impression, and a prefabricated auxiliary device was used to adjust the intraoral scans. Two zirconia frameworks with the same design were processed and evaluated intraorally by 2 independent calibrated observers.Results. In 11 of the 12 participants, the digitally processed prosthesis was preferred over the conventionally processed prosthesis. The clinical fit of the prostheses obtained with the completely digital workflow was better than that of those obtained with the conventional workflow.Conclusions. The use of a prefabricated auxiliary device after intraoral scanning allowed delivery of complete-arch implant-supported monolithic zirconia prostheses with a fit better than those fabricated from conventional impressions. (J Prosthet Dent 2022;128:404-14)
引用
收藏
页码:404 / 414
页数:11
相关论文
共 25 条
  • [1] Implementation of triple-scan protocol to evaluate the fit of complete-arch implant-supported fixed prostheses
    Donmez, Mustafa Borga
    Cakmak, Gulce
    Schimmel, Martin
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [2] Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses
    Mizumoto, Ryan M.
    Yilmaz, Burak
    McGlumphy, Edwin A., Jr.
    Seidt, Jeremy
    Johnston, William M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 96 - 104
  • [3] In vitro comparison of trueness of 10 intraoral scanners for implant-supported complete-arch fixed dental prostheses
    Bilmenoglu, Caglar
    Cilingir, Altug
    Geckili, Onur
    Bilhan, Hakan
    Bilgin, Tayfun
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 755 - 760
  • [4] Accuracy of digital impressions for implant-supported complete-arch prosthesis when using an auxiliary geometry device
    Arikan, Hale
    Muhtarogullari, Mehmet
    Uzel, Sema Merve
    Guncu, Mustafa Baris
    Aktas, Guliz
    Marshall, Lindsay Simone
    Turkyilmaz, Ilser
    [J]. JOURNAL OF DENTAL SCIENCES, 2023, 18 (02) : 808 - 813
  • [5] A combined digital and stereophotogrammetric technique for rehabilitation with immediate loading of complete-arch, implant-supported prostheses: A randomized controlled pilot clinical
    Penarrocha-Diago, Maria
    Carlos Balaguer-Marti, Jose
    Penarrocha-Oltra, David
    Francisco Balaguer-Martinez, Jose
    Penarrocha-Diago, Miguel
    Agustin-Panadero, Ruben
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (05): : 596 - 603
  • [6] A completely digital workflow for the transition from a failed dentition to interim complete-arch fixed implant-supported prostheses: A clinical report
    Negreiros, William Matthew
    Hamilton, Adam
    Gallucci, German O.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (04): : 527 - 532
  • [7] Accuracy of intraoral scan with prefabricated aids and stereophotogrammetry compared with open tray impressions for complete-arch implant-supported prosthesis: A clinical study
    Fu, Xiao-Jiao
    Liu, Min
    Liu, Bei-Lei
    Tonetti, Maurizio S.
    Shi, Jun-Yu
    Lai, Hong-Chang
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 830 - 840
  • [8] Conventional and digital maxillary occlusal record for the manufacture of complete-arch implant-supported fixed prostheses: randomized controlled clinical trial
    Pereira, Ana Larisse Carneiro
    Campos, Maria de Fatima Trindade Pinto
    Torres, Ana Clara Soares Paiva
    Carreiro, Adriana da Fonte Porto
    [J]. CLINICAL ORAL INVESTIGATIONS, 2024, 28 (05)
  • [9] Effect of splinting scan bodies on trueness of complete-arch implant impression using different intraoral scanners: an in vitro study
    Retana, Luciano
    Nejat, Amir H.
    Pozzi, Alessandro
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2023, 26 (01) : 19 - 28
  • [10] Fit of 3Y-TZP complete-arch implant-supported fixed dental prostheses before and after porcelain veneering
    Svanborg, Per
    Saarva, Veronika Norstrom
    Stenport, Victoria
    Eliasson, Alf
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (02): : 137 - 141