Accuracy of Complete-Arch Implant Digital Scans: Effect of Scanning Protocol, Number of Implants, and Scan Body Splinting

被引:1
|
作者
Denneulin, Thomas [1 ,2 ,3 ]
Rignon-Bret, Christophe [1 ,2 ,3 ]
Ravalec, Guy [2 ,4 ]
Tapie, Laurent [5 ,6 ]
Bouter, Denis [7 ]
Wulfman, Claudine [1 ,2 ,8 ]
机构
[1] Univ Paris, Prosthodont Dept, Montrouge, France
[2] Univ Sorbonne Paris Nord, Bobigny, France
[3] CHU Lille, Serv Med Bucco Dentaire, Lille, France
[4] Montrouge Hop Pontchaillou, Serv Med Buccodentaire, Rennes, France
[5] Univ Sorbonne Paris Nord, Biomat Dept, Bobigny, France
[6] Univ Paris, Montrouge, France
[7] Univ Paris, Restorat Dent Dept, Serv Med Buccodentaire, Henri Mondor,AP HP, Creteil, France
[8] Hop Henri Mondor, AP HP, Serv Med Buccodentaire, Creteil, France
关键词
3-DIMENSIONAL ACCURACY; MULTIPLE IMPLANTS; INTRAORAL SCANNER; AMBIENT LIGHT; IMPRESSIONS; PRECISION; SYSTEM; FABRICATION; TECHNOLOGY; ANGULATION;
D O I
10.11607/ijp.7332
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To determine the effect of scanning protocol, number of implants, and implant splinting on the accuracy of digital scanning in the edentulous arch. Materials and Methods: A resin-based model of an edentulous mandible with six implants was scanned with a coordinate measurement machine as a reference and then with two intraoral scanner (IOS) systems (Trios 3 and Primescan). Ten scans were taken per IOS for three experiments, and each scan was compared to the reference data to evaluate trueness and precision. Analysis involved measurement of linear and angular discrepanices using engineering software. In experiment 1, three scanning protocols were compared (curvilinear, zigzag, and half-arch). In experiment 2, three clinical situations were simulated (6 implants, 4 implants-short arch, and 4 implants-long arch). In experiment 3, the effect of implant splinting with a suture thread was measured. Normal distribution of data was examined with Shapiro-Wilk test. Levene test was used for equality of variance (& alpha; = .05). Statistical differences in distance and angular deviations were analyzed using Student t test or ANOVA with post hoc Tukey test (& alpha; = .05). Results: The best results in terms of trueness and precision were obtained with a linear scanning protocol and six implants. The results were as follows: Trios 3: trueness = 52 pm/0.42 degrees, precision = 40 pm/0.26 degrees; Primescan: trueness = 24 pm/0.28 degrees, precision = 18 pm/0.27 degrees. The scanning protocol did not significantly affect distance or angular deviation accuracy. Trueness and precision significantly decreased with four implants using Primescan and TRIOS 3. Splinting implants negatively affected accuracy with both IOS devices. Conclusion: Both IOS devices achieved clinically satisfying accuracy for distance (< 100 pm) and angular (< 0.5 degrees) deviations with six implants and a linear scanning protocol. With four implants, angular deviations sometimes differed between implants within the same group depending on the IOS and the clinical situation. Int J Prosthodont 2023;36:219-227. doi: 10.11607/ijp.7332
引用
收藏
页码:219 / 227
页数:9
相关论文
共 50 条
  • [1] The effect of scanning the palate and scan body position on the accuracy of complete-arch implant scans
    Mizumoto, Ryan M.
    Alp, Gulce
    Ozcan, Mutlu
    Yilmaz, Burak
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 987 - 994
  • [2] The effect of scanner type and scan body position on the accuracy of complete-arch digital implant scans
    Cakmak, Gulce
    Yilmaz, Hakan
    Trevino, Alejandro
    Kokat, Ali Murat
    Yilmaz, Burak
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) : 533 - 541
  • [3] Influence of scanning protocol on the accuracy of complete-arch digital implant scans: An in vitro study
    Hamilton, Adam
    Negreiros, William Matthew
    Jain, Shruti
    Finkelman, Matthew
    Gallucci, German O.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (06) : 641 - 651
  • [4] Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete-arch intraoral digital implant scans
    Gomez-Polo, Miguel
    Cascos, Rocio
    Ortega, Rocio
    Barmak, Abdul B.
    Kois, John C.
    Revilla-Leon, Marta
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (06) : 591 - 601
  • [5] Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study
    Cakmak, Gulce
    Yilmaz, Hakan
    Santos, Alejandro Trevino
    Kokat, Ali Murat
    Yilmaz, Burak
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 419 - 426
  • [6] Accuracy of complete-arch digital implant impression with or without scanbody splinting: An in vitro study
    Pozzi, Alessandro
    Arcuri, Lorenzo
    Lio, Fabrizio
    Papa, Andrea
    Nardi, Alessandra
    Londono, Jimmy
    [J]. JOURNAL OF DENTISTRY, 2022, 119
  • [7] Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses
    Mizumoto, Ryan M.
    Yilmaz, Burak
    McGlumphy, Edwin A., Jr.
    Seidt, Jeremy
    Johnston, William M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 96 - 104
  • [8] Effect of scan pattern on complete-arch scans with 4 digital scanners
    Latham, Jason
    Ludlow, Mark
    Mennito, Anthony
    Kelly, Abigail
    Evans, Zachary
    Renne, Walter
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 85 - 95
  • [9] Effect of Scan Pattern on the Accuracy of Complete-Arch Digital Implant Impressions with Two Intraoral Scanners
    Li, Zhipeng
    Huang, Ruoxuan
    Wu, Xiayi
    Chen, Zetao
    Huang, Baoxin
    Chen, Zhuofan
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 731 - 739
  • [10] Comparison of the accuracy of intraoral scans between complete-arch scan and quadrant scan
    Youn-Gyeong Moon
    Kyung-Min Lee