Accuracy of Complete-Arch Implant Digital Scans: Effect of Scanning Protocol, Number of Implants, and Scan Body Splinting

被引:1
|
作者
Denneulin, Thomas [1 ,2 ,3 ]
Rignon-Bret, Christophe [1 ,2 ,3 ]
Ravalec, Guy [2 ,4 ]
Tapie, Laurent [5 ,6 ]
Bouter, Denis [7 ]
Wulfman, Claudine [1 ,2 ,8 ]
机构
[1] Univ Paris, Prosthodont Dept, Montrouge, France
[2] Univ Sorbonne Paris Nord, Bobigny, France
[3] CHU Lille, Serv Med Bucco Dentaire, Lille, France
[4] Montrouge Hop Pontchaillou, Serv Med Buccodentaire, Rennes, France
[5] Univ Sorbonne Paris Nord, Biomat Dept, Bobigny, France
[6] Univ Paris, Montrouge, France
[7] Univ Paris, Restorat Dent Dept, Serv Med Buccodentaire, Henri Mondor,AP HP, Creteil, France
[8] Hop Henri Mondor, AP HP, Serv Med Buccodentaire, Creteil, France
关键词
3-DIMENSIONAL ACCURACY; MULTIPLE IMPLANTS; INTRAORAL SCANNER; AMBIENT LIGHT; IMPRESSIONS; PRECISION; SYSTEM; FABRICATION; TECHNOLOGY; ANGULATION;
D O I
10.11607/ijp.7332
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To determine the effect of scanning protocol, number of implants, and implant splinting on the accuracy of digital scanning in the edentulous arch. Materials and Methods: A resin-based model of an edentulous mandible with six implants was scanned with a coordinate measurement machine as a reference and then with two intraoral scanner (IOS) systems (Trios 3 and Primescan). Ten scans were taken per IOS for three experiments, and each scan was compared to the reference data to evaluate trueness and precision. Analysis involved measurement of linear and angular discrepanices using engineering software. In experiment 1, three scanning protocols were compared (curvilinear, zigzag, and half-arch). In experiment 2, three clinical situations were simulated (6 implants, 4 implants-short arch, and 4 implants-long arch). In experiment 3, the effect of implant splinting with a suture thread was measured. Normal distribution of data was examined with Shapiro-Wilk test. Levene test was used for equality of variance (& alpha; = .05). Statistical differences in distance and angular deviations were analyzed using Student t test or ANOVA with post hoc Tukey test (& alpha; = .05). Results: The best results in terms of trueness and precision were obtained with a linear scanning protocol and six implants. The results were as follows: Trios 3: trueness = 52 pm/0.42 degrees, precision = 40 pm/0.26 degrees; Primescan: trueness = 24 pm/0.28 degrees, precision = 18 pm/0.27 degrees. The scanning protocol did not significantly affect distance or angular deviation accuracy. Trueness and precision significantly decreased with four implants using Primescan and TRIOS 3. Splinting implants negatively affected accuracy with both IOS devices. Conclusion: Both IOS devices achieved clinically satisfying accuracy for distance (< 100 pm) and angular (< 0.5 degrees) deviations with six implants and a linear scanning protocol. With four implants, angular deviations sometimes differed between implants within the same group depending on the IOS and the clinical situation. Int J Prosthodont 2023;36:219-227. doi: 10.11607/ijp.7332
引用
收藏
页码:219 / 227
页数:9
相关论文
共 50 条
  • [31] Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods
    Mai, Hai Yen
    Mai, Hang-Nga
    Lee, Cheong-Hee
    Lee, Kyu-Bok
    Kim, So-yeun
    Lee, Jae-Mok
    Lee, Keun-Woo
    Lee, Du-Hyeong
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (02): : 88 - 95
  • [32] Effect of novel prefabricated auxiliary devices attaching to scan bodies on the accuracy of intraoral scanning of complete-arch with multiple implants: An in-vitro study
    Wu, Hio Kuan
    Wang, Jing
    Chen, Guanhui
    Huang, Xiaoqiong
    Deng, Feilong
    Li, Yiming
    [J]. JOURNAL OF DENTISTRY, 2023, 138
  • [33] Improved scanning accuracy with newly designed scan bodies: An in vitro study comparing digital versus conventional impression techniques for complete-arch implant rehabilitation
    Huang, Ruoxuan
    Liu, Yuanxiang
    Huang, Baoxin
    Zhang, Chaobiao
    Chen, Zhuofan
    Li, Zhipeng
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (07) : 625 - 633
  • [34] Accuracy of digital complete-arch, multi-implant scans made in the edentulous jaw with gingival movement simulation: An in vitro study
    Knechtle, Nathalie
    Wiedemeier, Daniel
    Mehl, Albert
    Ender, Andreas
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 468 - 478
  • [35] Effect of artificial landmarks of the prefabricated auxiliary devices located at different arch positions on the accuracy of complete-arch edentulous digital implant scanning: An in-vitro study
    Wu, Hio Kuan
    Chen, Guanhui
    Zhang, Zhengchuan
    Lin, Xiaoxuan
    Huang, Xiaoqiong
    Deng, Feilong
    Li, Yiming
    [J]. JOURNAL OF DENTISTRY, 2024, 140
  • [36] Effect of using scan body accessories and inter-implant distances on the accuracy of complete arch implant digital impressions: An in vitro study
    Ashry, Amal
    Abdelhamid, Ahmed M.
    Ezzelarab, Salah
    Khamis, Mohamed Moataz
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [37] Guided implant scanning: A procedure for improving the accuracy of implant-supported complete-arch fixed dental prostheses
    Gomez-Polo, Miguel
    Ballesteros, Juan
    Perales-Padilla, Pedro
    Perales-Pulido, Pedro
    Gomez-Polo, Cristina
    Ortega, Rocio
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 135 - 139
  • [38] Obtaining reliable intraoral digital scans for an implant-supported complete-arch prosthesis: A dental technique
    Iturrate, Mikel
    Minguez, Rikardo
    Pradies, Guillermo
    Solaberrieta, Eneko
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (02): : 237 - 241
  • [39] Accuracy of three digital scanning methods for complete-arch tooth preparation: An in vitro comparison
    Gao, Hanqi
    Liu, Xiaoqiang
    Liu, Mingyue
    Yang, Xu
    Tan, Jianguo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1001 - 1008
  • [40] Effect of a Novel 'Scan Body' on the In Vitro Scanning Accuracy of Full-Arch Implant Impressions
    Zhang, Tingting
    Yang, Bo
    Ge, Ruihan
    Zhang, Chaobiao
    Zhang, Hui
    Wang, Yan
    [J]. INTERNATIONAL DENTAL JOURNAL, 2024, 74 (04) : 847 - 854