Flow rate estimation of a centrifugal blood pump using the passively stabilized eccentric position of a magnetically levitated impeller

被引:7
|
作者
Shidai, Shuya [1 ]
Masuzawa, Toru [2 ]
Osa, Masahiro [2 ]
机构
[1] Ibaraki Univ, Grad Sch Sci & Engn, 4-12-1 Nakanarusawa, Hitachi, Ibaraki 3168511, Japan
[2] Ibaraki Univ, Dept Mech Engn, 4-12-1 Nakanarusawa, Hitachi, Ibaraki 3168511, Japan
来源
关键词
Flow rate estimation; magnetically levitated impeller; centrifugal blood pump; passive stabilization; eccentric impeller position; PULSATILE FLOW; VISCOSITY; DEVICE;
D O I
10.1177/0391398819833372
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Flow rate estimation for ventricular assist devices without additional flow sensors can improve the quality of life of patients. In this article, a novel flow estimation method using the passively stabilized displacement of a magnetically levitated impeller is developed to achieve sufficient accuracy and precision of flow estimation for ventricular assist devices in a simple manner. The magnetically levitated impeller used is axially suspended by a magnetic bearing in a centrifugal blood pump that has been developed by our group. The radial displacement of the impeller, which is restricted by passive stability, can be correlated with the flow rate because the radial hydraulic force on the impeller varies according to the flow rate. To obtain the correlation with various blood viscosities, the relationships between the radial displacements of the magnetically levitated impeller and the pressure head-flow rate characteristics of the pump were determined simultaneously using aqueous solutions of glycerol with a potential blood viscosity range. The measurement results showed that accurate steady flow rates could be estimated with a coefficient of determination of approximately 0.97 and mean absolute error of approximately 0.22 L/min without fluid viscosity measurements by using the relationships between the impeller displacement and the flow rate. Moreover, a precision of approximately 0.01 (L/min)/mu m was obtained owing to a strong estimation indicator signal provided by the large displacement of the passively stabilized impeller; thus, the proposed estimation method can help ensure sufficient accuracy and precision for ventricular assist devices in a simple manner, even if the blood viscosity is unknown.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [21] A magnetically levitated centrifugal blood pump with a simple-structured disposable pump head
    Hijikata, Wataru
    Shinshi, Tadahiko
    Asama, Junichi
    Li, Lichuan
    Hoshi, Hideo
    Takatani, Setsuo
    Shimokohbe, Akira
    ARTIFICIAL ORGANS, 2008, 32 (07) : 531 - 540
  • [22] Visualization of flow structure in a centrifugal blood pump impeller
    Tsukiya T.
    Taenaka Y.
    Tatsumi E.
    Takano H.
    Journal of Artificial Organs, 2002, 5 (1) : 13 - 17
  • [23] A cost-effective extracorporeal magnetically-levitated centrifugal blood pump employing a disposable magnet-free impeller
    Hijikata, W.
    Mamiya, T.
    Shinshi, T.
    Takatani, S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H12) : 1149 - 1157
  • [24] Flow rate and pressure head estimation in a centrifugal blood pump
    Funakubo, A
    Ahmed, S
    Sakuma, I
    Fukui, Y
    ARTIFICIAL ORGANS, 2002, 26 (11) : 985 - 990
  • [25] Experimental study on the whirling motion in the centrifugal blood pump with a magnetically coupled impeller
    Tsukiya, Tomonori
    Taenaka, Yoshiyuki
    Suzuki, Takayuki
    Horiguchi, Hironori
    Tsujimoto, Yoshinobu
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2008, 74 (07): : 1557 - 1563
  • [26] Radial Passive Stability Analysis of Magnetically Levitated Impeller Position for the Development of Flow Rate Estimations of a Ventricular Assist Device
    Shida, Shuya
    Masuzawa, Toru
    Osa, Masahiro
    ADVANCED BIOMEDICAL ENGINEERING, 2022, 11 : 194 - 202
  • [27] Visualization study of the transient flow in the centrifugal blood pump impeller
    Tsukiya, T
    Taenaka, Y
    Tatsumi, E
    Takano, H
    ASAIO JOURNAL, 2002, 48 (04) : 431 - 436
  • [28] Use of motor current in flow rate measurement for the magnetically suspended centrifugal blood pump
    Tsukiya, T
    Akamatsu, T
    Nishimura, K
    Yamada, T
    Nakazeki, T
    ARTIFICIAL ORGANS, 1997, 21 (05) : 396 - 401
  • [29] Feasibility and Flexibility of Magnetically Levitated Centrifugal-Flow Pump for Patients with Cardiogenic Shock
    Takayama, H.
    Soni, L. K.
    Koeckert, M.
    Cogan, J.
    Cedola, S. R.
    Jones, D.
    Jiang, J.
    Horai, T.
    Ota, T.
    Uriel, N.
    Colombo, P.
    Jorde, U.
    Mancini, D.
    Chen, J.
    Naka, Y.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S270 - S270
  • [30] End-of-Life Care in Recipients of Magnetically Levitated Centrifugal-Flow Pump
    Soni, L. K.
    Jones, D. L.
    Cedola, S. R.
    Cogan, J.
    Shulman, B.
    Kossar, A.
    Jiang, J.
    Koeckert, M.
    Yerebakan, H.
    Naka, Y.
    Takayama, H.