Flow rate estimation of a centrifugal blood pump using the passively stabilized eccentric position of a magnetically levitated impeller

被引:7
|
作者
Shidai, Shuya [1 ]
Masuzawa, Toru [2 ]
Osa, Masahiro [2 ]
机构
[1] Ibaraki Univ, Grad Sch Sci & Engn, 4-12-1 Nakanarusawa, Hitachi, Ibaraki 3168511, Japan
[2] Ibaraki Univ, Dept Mech Engn, 4-12-1 Nakanarusawa, Hitachi, Ibaraki 3168511, Japan
来源
关键词
Flow rate estimation; magnetically levitated impeller; centrifugal blood pump; passive stabilization; eccentric impeller position; PULSATILE FLOW; VISCOSITY; DEVICE;
D O I
10.1177/0391398819833372
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Flow rate estimation for ventricular assist devices without additional flow sensors can improve the quality of life of patients. In this article, a novel flow estimation method using the passively stabilized displacement of a magnetically levitated impeller is developed to achieve sufficient accuracy and precision of flow estimation for ventricular assist devices in a simple manner. The magnetically levitated impeller used is axially suspended by a magnetic bearing in a centrifugal blood pump that has been developed by our group. The radial displacement of the impeller, which is restricted by passive stability, can be correlated with the flow rate because the radial hydraulic force on the impeller varies according to the flow rate. To obtain the correlation with various blood viscosities, the relationships between the radial displacements of the magnetically levitated impeller and the pressure head-flow rate characteristics of the pump were determined simultaneously using aqueous solutions of glycerol with a potential blood viscosity range. The measurement results showed that accurate steady flow rates could be estimated with a coefficient of determination of approximately 0.97 and mean absolute error of approximately 0.22 L/min without fluid viscosity measurements by using the relationships between the impeller displacement and the flow rate. Moreover, a precision of approximately 0.01 (L/min)/mu m was obtained owing to a strong estimation indicator signal provided by the large displacement of the passively stabilized impeller; thus, the proposed estimation method can help ensure sufficient accuracy and precision for ventricular assist devices in a simple manner, even if the blood viscosity is unknown.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [31] Noninvasive pump flow estimation of a centrifugal blood pump
    Wakisaka, Y
    Okuzono, Y
    Taenaka, Y
    Chikanari, K
    Masuzawa, T
    Nakatani, T
    Tatsumi, E
    Nishimura, T
    Takewa, Y
    Ohno, T
    Takano, H
    ARTIFICIAL ORGANS, 1997, 21 (07) : 651 - 654
  • [32] Centrifugal blood pump with a hydraulically-levitated impeller for a permanently implantable biventricular assist device
    Watanabe, K
    Ichikawa, S
    Asai, T
    Motomura, T
    Hata, A
    Ito, S
    Shinohara, T
    Tsujimura, S
    Glueck, JA
    Oestmann, DJ
    Nosé, Y
    ARTIFICIAL ORGANS, 2004, 28 (06) : 556 - 563
  • [33] Development of a centrifugal blood pump with magnetically suspended impeller and the related fluid mechanical problems
    T Akamatsu
    T Tsukiya
    Sadhana, 1998, 23 : 597 - 603
  • [34] Flow visualization in a centrifugal blood pump with an eccentric inlet port
    Yamane, T
    Kodama, T
    Yamamoto, Y
    Shinohara, T
    Nosé, Y
    ARTIFICIAL ORGANS, 2004, 28 (06) : 564 - 570
  • [35] Development of a centrifugal blood pump with magnetically suspended impeller and the related fluid mechanical problems
    Akamatsu, T
    Tsukiya, T
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 1998, 23 (5-6): : 597 - 603
  • [36] The flow patterns within the impeller passages of a centrifugal blood pump model
    Yu, SCM
    Ng, BTH
    Chan, WK
    Chua, LP
    MEDICAL ENGINEERING & PHYSICS, 2000, 22 (06) : 381 - 393
  • [37] Effects of oscillation frequency on the flow characteristics of a centrifugal pump impeller with sinusoidal flow rate
    Kuang, Renfei
    Li, Yu
    Chen, Xiaoping
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2023, 237 (18) : 4246 - 4255
  • [38] Serial Assessment of Magnetically Levitated Centrifugal-Flow LVAD Pump Position and Inflow Angle on Chest Radiograph and Effects on Adverse Events
    Butler, C.
    Naka, Y.
    Sanchez, J.
    Malick, A.
    Melehy, A.
    Kurlansky, P.
    Ning, Y.
    Nemeth, S.
    Topkara, V.
    Yuzefpolskaya, M.
    Colombo, P.
    Sayer, G.
    Uriel, N.
    Takayama, H.
    Takeda, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2020, 39 (04): : S412 - S412
  • [39] Effects of oscillation frequency on the flow characteristics of a centrifugal pump impeller with sinusoidal flow rate
    Kuang, Renfei
    Li, Yu
    Chen, Xiaoping
    Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 2023, 237 (18): : 4246 - 4255
  • [40] Evaluation of Erythrocyte Flow at a Bearing Gap in a Hydrodynamically Levitated Centrifugal Blood Pump
    Murashige, Tomotaka
    Kosaka, Ryo
    Sakota, Daisuke
    Nishida, Masahiro
    Kawaguchi, Yasuo
    Yamane, Takashi
    Maruyama, Osamu