Evaluation of Erythrocyte Flow at a Bearing Gap in a Hydrodynamically Levitated Centrifugal Blood Pump

被引:0
|
作者
Murashige, Tomotaka [1 ]
Kosaka, Ryo [2 ]
Sakota, Daisuke [2 ]
Nishida, Masahiro [2 ]
Kawaguchi, Yasuo [3 ]
Yamane, Takashi [4 ]
Maruyama, Osamu [2 ]
机构
[1] Tokyo Univ Sci, Grad Sch Sci & Technol, 2641 Yamazaki, Noda, Chiba 2788510, Japan
[2] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058564, Japan
[3] Tokyo Univ Sci, Noda, Chiba 2788510, Japan
[4] Kobe Univ, Grad Sch Engn, Nada Ku, Kobe, Hyogo 6578501, Japan
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a hydrodynamically levitated centrifugal blood pump for extracorporeal circulatory support. In the blood pump, a spiral groove bearing was adopted for a thrust bearing. In the spiral groove bearing, separation of erythrocytes and plasma by plasma skimming has been postulated to occur. However, it is not clarified that plasma skimming occurs in a spiral groove bearing. The purpose of this study is to verify whether plasma skimming occurs in the spiral groove bearing of a hydrodynamically levitated centrifugal blood pump. For evaluation of plasma skimming in the spiral groove bearing, an impeller levitation performance test using a laser focus displacement meter and a microscopic visualization test of erythrocyte flow using a high-speed microscope were conducted. Bovine blood diluted with autologous plasma to adjust hematocrit to 1.0% was used as a working fluid. Hematocrit on the ridge region in the spiral groove bearing was estimated using image analysis. As a result, hematocrits on the ridge region with gaps of 45 mu m, 31 mu m, and 25 mu m were calculated as 1.0%, 0.6%, and 0.3%, respectively. Maximum skimming efficiency in this study was calculated as 70% with a gap of 25 mu m. We confirmed that separation of erythrocyte and plasma occurred in the spiral groove bearing with decrease in bearing gap in a hydrodynamically levitated centrifugal blood pump.
引用
收藏
页码:270 / 273
页数:4
相关论文
共 50 条
  • [1] Bearing Gap Adjustment for Improvement of Levitation Performance in a Hydrodynamically Levitated Centrifugal Blood Pump
    Kosaka, Ryo
    Yoshida, Fumihiko
    Nishida, Masahiro
    Maruyama, Osamu
    Kawaguchi, Yasuo
    Yamane, Takashi
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 3295 - 3298
  • [2] Optimal Bearing Gap of a Multiarc Radial Bearing in a Hydrodynamically Levitated Centrifugal Blood Pump for the Reduction of Hemolysis
    Kosaka, Ryo
    Yasui, Kazuya
    Nishida, Masahiro
    Kawaguchi, Yasuo
    Maruyama, Osamu
    Yamane, Takashi
    [J]. ARTIFICIAL ORGANS, 2014, 38 (09) : 818 - 822
  • [3] Effect of a bearing gap on hemolytic property in a hydrodynamically levitated centrifugal blood pump with a semi-open impeller
    Kosaka, Ryo
    Nishida, Masahiro
    Maruyama, Osamu
    Yambe, Tomoyuki
    Imachi, Kou
    Yamane, Takashi
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2013, 23 (1-2) : 37 - 47
  • [4] Geometric Optimization of a Step Bearing for a Hydrodynamically Levitated Centrifugal Blood Pump for the Reduction of Hemolysis
    Kosaka, Ryo
    Yada, Toru
    Nishida, Masahiro
    Maruyama, Osamu
    Yamane, Takashi
    [J]. ARTIFICIAL ORGANS, 2013, 37 (09) : 778 - 785
  • [5] A Novel Design of Spiral Groove Bearing in a Hydrodynamically Levitated Centrifugal Rotary Blood Pump
    Han, Qing
    Zou, Jun
    Ruan, Xiaodong
    Fu, Xin
    Yang, Huayong
    [J]. ARTIFICIAL ORGANS, 2012, 36 (08) : 739 - 746
  • [6] Evaluation of a Spiral Groove Geometry for Improvement of Hemolysis Level in a Hydrodynamically Levitated Centrifugal Blood Pump
    Murashige, Tomotaka
    Kosaka, Ryo
    Sakota, Daisuke
    Nishida, Masahiro
    Kawaguchi, Yasuo
    Yamane, Takashi
    Maruyama, Osamu
    [J]. ARTIFICIAL ORGANS, 2015, 39 (08) : 710 - 714
  • [7] Fluid Dynamic Design for Low Hemolysis in a Hydrodynamically Levitated Centrifugal Blood Pump
    Murashige, Tomotaka
    Kosaka, Ryo
    Nishida, Masahiro
    Maruyama, Osamu
    Yamane, Takashi
    Kuwana, Katsuyuki
    Kawaguchi, Yasuo
    [J]. 2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2732 - 2735
  • [8] Improvement of hemolysis performance in a hydrodynamically levitated centrifugal blood pump by optimizing a shroud size
    Ryo Kosaka
    Daisuke Sakota
    Masahiro Nishida
    Osamu Maruyama
    Takashi Yamane
    [J]. Journal of Artificial Organs, 2021, 24 : 157 - 163
  • [9] Numerical simulation of the leakage flow of the hydrodynamically levitated centrifugal blood pump for extracorporeal mechanical circulatory support systems
    Tsukiya, Tomonori
    Nishinaka, Tomohiro
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2023, 26 (03) : 176 - 183
  • [10] Numerical simulation of the leakage flow of the hydrodynamically levitated centrifugal blood pump for extracorporeal mechanical circulatory support systems
    Tomonori Tsukiya
    Tomohiro Nishinaka
    [J]. Journal of Artificial Organs, 2023, 26 : 176 - 183