Factors influencing size-specific dose estimates of selected computed tomography protocols at two clinical practices in South Africa

被引:2
|
作者
Sebelego, Ida-Keshia [1 ]
Acho, Sussan [2 ]
van der Merwe, Belinda [1 ]
Rae, William I. D. [2 ,3 ]
机构
[1] Cent Univ Technol, Fac Hlth & Environm Sci, Dept Clin Sci, ZA-9301 Bloemfontein, South Africa
[2] Univ Free State, Fac Hlth Sci, Dept Med Phys, ZA-9300 Bloemfontein, South Africa
[3] Prince Wales Hosp, Med Imaging Dept, Randwick 2133, Australia
基金
新加坡国家研究基金会;
关键词
DIAGNOSTIC REFERENCE LEVELS; TUBE CURRENT MODULATION; IMAGE QUALITY; CT; IMPACT;
D O I
10.1093/rpd/ncad059
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study aimed to determine the factors that impact the size-specific dose estimate (SSDE) for computed tomography (CT) examinations of the chest-abdomen-pelvis and abdomen-pelvis protocols in two clinical radiology practices and evaluate the image quality of these protocols. Imaging parameters, protocols, dose metrics from the CT units and size-related parameters to calculate the SSDE were documented. The image quality of the CT images was assessed using an image subtraction algorithm. The SSDE increased as the volumetric CT dose index (CTDIvol), and the patient's body mass index increased, respectively. Significant differences (p < 0.001) occurred between the two hospitals regarding image quality. However, these differences were not indicative of differences in the diagnostic performances for task-based imaging protocols. Different clinical protocols should be reviewed to optimise dose. The inclusion of the pre-monitoring sequence, age of the machine and the scan requisition parameters impacted the SSDEs. Image quality should be assessed to evaluate the consistency of image quality between protocols applied by different CT units when assessing SSDEs.
引用
收藏
页码:588 / 602
页数:15
相关论文
共 50 条
  • [31] Effect of table height displacement and patient center deviation on size-specific dose estimates calculated from computed tomography localizer radiographs
    Kazuki Kuriyama
    Kosuke Matsubara
    Shu Hisahara
    Yukie Nagata
    Rumiko Nosaka
    Rika Goto
    Nobutaka Yanano
    Kanichiro Shimizu
    Tomokazu Shoji
    Physical and Engineering Sciences in Medicine, 2020, 43 : 665 - 672
  • [32] Radiation dose of head and abdomen-pelvis computed tomography examinations using size-specific dose estimate
    Ahmadifard, M.
    Bakhshandeh, M.
    Mohammadbeigi, A.
    Khoshgard, K.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (01): : 185 - 189
  • [33] Size-specific dose estimates calculated using patient size measurements from scanned projection radiograph in high-resolution chest computed tomography
    Brindhaban, Ajit
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2025, 72 (01) : 85 - 92
  • [34] Development of a novel automated algorithm for patient dosimetry in computed tomography: a step towards the facilitation of size-specific dose estimates and organs dosimetry estimations in a busy clinical workflow
    Sekkat, Hamza
    Khallouqi, Abdellah
    Madkouri, Youssef
    El Atifi, Wiam
    Rhouch, Imane
    El Rhazouani, Omar
    Tahiri, Zakaria
    Talbi, Mohammed
    Halimi, Abdellah
    PHYSICA SCRIPTA, 2024, 99 (12)
  • [35] Size-specific dose estimates for pediatric head CT protocols based on the AAPM report TG-293
    Sapignoli, Sonia
    Roggio, Antonella
    Boschini, Alessio
    Guida, Federica
    Merlo, Carlo
    Paiusco, Marta
    Zorz, Alessandra
    De Monte, Francesca
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 100 : 26 - 30
  • [36] Impact of acquisition mode of CBCT scans on size-specific dose estimates (SSDE) conversion factors
    Abuhaimed, A.
    Martin, C.
    Demirkaya, O.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S905 - S906
  • [37] Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations
    Hamza Sulemana
    Abdul Nashirudeen Mumuni
    Izre-deen Osman Mohammed Abubakari
    Egyptian Journal of Radiology and Nuclear Medicine, 55 (1):
  • [38] Evaluating the Utilization of the National Cancer Institute Computed Tomography Program for Calculating Size-specific Dose Estimate and Effective Dose in Computed Tomography in Thai Pediatric Patients
    Sookpeng, Supawitoo
    Martin, Colin J.
    Rattanarungruangchai, Natch
    Lopez-Gonzalez, M. Rosario
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (04) : 710 - 718
  • [39] Analysis of size-specific dose profiles beyond the scan range in water phantoms undergoing computed tomography examinations
    Masoudi, M.
    Faghihi, R.
    Sina, S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (03): : 551 - 557
  • [40] Local diagnostic reference level based on size-specific dose estimates: Assessment of pediatric abdominal/pelvic computed tomography at a Japanese national children’s hospital
    Rumi Imai
    Osamu Miyazaki
    Tetsuya Horiuchi
    Hideo Kurosawa
    Shunsuke Nosaka
    Pediatric Radiology, 2015, 45 : 345 - 353