Evaluating the Utilization of the National Cancer Institute Computed Tomography Program for Calculating Size-specific Dose Estimate and Effective Dose in Computed Tomography in Thai Pediatric Patients

被引:0
|
作者
Sookpeng, Supawitoo [1 ]
Martin, Colin J. [2 ]
Rattanarungruangchai, Natch [3 ]
Lopez-Gonzalez, M. Rosario [4 ]
机构
[1] Naresuan Univ, Fac Allied Hlth Sci, Dept Radiol Technol, Phitsanulok, Thailand
[2] Univ Glasgow, Dept Clin Phys & Bioengn, Glasgow, Lanark, Scotland
[3] Thailand Inst Nucl Technol, Nakhon Nayok, Thailand
[4] Univ Glasgow, Inst Neurosci & Psychol, Dept Clin Phys & Bioengn, Glasgow, Lanark, Scotland
关键词
Monte Carlo simulation; National Cancer Institute computed tomography; pediatric patient; size-specific dose estimate; size-specific effective dose; CT;
D O I
10.4103/jmp.jmp_49_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objectives of this study were to assess the feasibility of utilizing computational calculations and the simulation of the National Cancer Institute computed tomography (NCICT) dosimetry system to obtain size-specific dose estimate (SSDE) and effective dose values resulting from the most common CT examinations in Thai pediatric patients and to evaluate age- and size-specific k conversion factor. For the calculation methods, SSDEs were calculated using the American Association of Physicists in Medicine Report No. 220 and 293 methodologies. The results revealed that SSDEs derived from CT scans of the body, obtained through the two different methods, varied by within 10%. The size of the patient and the scanning distance had an impact on the variability of E values derived from NCICT. Age- and size-specific k conversion factors may be used as a first line to estimate risk for the pediatric patients.
引用
收藏
页码:710 / 718
页数:9
相关论文
共 50 条
  • [1] Size-Specific Dose Estimate and Effective Dose for Pediatric Computed Tomography
    Khan, Rukhsar
    Shah, Mudasir Ashraf
    Wahab, Shagufta
    Khan, Rizwan Ahmad
    JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) : 173 - 183
  • [2] THE SIZE-SPECIFIC DOSE ESTIMATE (SSDE) FOR TRUNCATED COMPUTED TOMOGRAPHY IMAGES
    Anam, Choirul
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 313 - 320
  • [3] Size-Specific Dose Estimates in Fetal Computed Tomography
    Kobayashi, Masanao
    Nishihara, Yusei
    Haba, Tomonobu
    Matsunaga, Yuta
    Minami, Kazuyuki
    Asada, Yasuki
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (06) : 339 - 348
  • [4] Multivariate Analysis of Effective Dose and Size-Specific Dose Estimates for Thorax and Abdominal Computed Tomography
    Shah, Mudasir Ashraf
    Ahmad, Mehtab
    Khalid, Saifullah
    Qaseem, Syed M. Danish
    Siddiqui, Shaista
    Talib, Sayema
    Rather, Sajad Ahmed
    Firdous, Arfat
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (02) : 210 - 218
  • [5] ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY
    Boos, Johannes
    Kroepil, Patric
    Bethge, Oliver Th.
    Aissa, Joel
    Schleich, Christoph
    Sawicki, Lino Morris
    Heinzler, Niklas
    Antoch, Gerald
    Thomas, Christoph
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 8 - 19
  • [6] Novel method for calculating the effective dose using size-specific dose estimates conversion factors in abdomen–pelvis computed tomography
    Kentaro Funashima
    Shigeru Abiko
    Kazuhiro Sato
    Radiological Physics and Technology, 2023, 16 (4) : 506 - 515
  • [7] A simple manual method to estimate water-equivalent diameter for calculating size-specific dose estimate in chest computed tomography
    Mihailidis, Dimitris
    Tsapaki, Virginia
    Tomara, Pelagia
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1117):
  • [8] Radiation dose of head and abdomen-pelvis computed tomography examinations using size-specific dose estimate
    Ahmadifard, M.
    Bakhshandeh, M.
    Mohammadbeigi, A.
    Khoshgard, K.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (01): : 185 - 189
  • [9] Novel method for calculating the effective dose using size-specific dose estimates conversion factors in abdomen-pelvis computed tomography
    Funashima, Kentaro
    Abiko, Shigeru
    Sato, Kazuhiro
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (04) : 506 - 515
  • [10] Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation
    Xu, Jian
    He, Xiaolong
    Xiao, Huawei
    Xu, Jianguo
    MEDICAL SCIENCE MONITOR, 2019, 25 : 71 - 76