Effect of table height displacement and patient center deviation on size-specific dose estimates calculated from computed tomography localizer radiographs

被引:0
|
作者
Kazuki Kuriyama
Kosuke Matsubara
Shu Hisahara
Yukie Nagata
Rumiko Nosaka
Rika Goto
Nobutaka Yanano
Kanichiro Shimizu
Tomokazu Shoji
机构
[1] The Jikei University Kashiwa Hospital,Department of Radiology
[2] Kanazawa University,Division of Health Sciences, Department of Quantum Medical Technology, Graduate Course of Medical Science and Technology, Graduate School of Medical Science
[3] Kanazawa University,Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences
[4] The Jikei University School of Medicine,Department of Radiology
[5] Kashiwa Hospital,Department of Radiology
[6] The Jikei University Hospital,undefined
关键词
Size-specific dose estimate; Miscentering; Table height; Computed tomography; Localizer radiograph;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study is to evaluate the effect of table height displacement and patient center deviation along the z\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$z$$\end{document}-axis on size-specific dose estimate (SSDE) calculations based on computed tomography (CT) localizer radiographs in pediatric and adult abdominal CT examinations. CT localizer radiographs and CT axial images were acquired with table heights of − 5.0, − 2.5, 0.0 (center), 2.5, and 5.0 cm using two acrylic self-made phantoms filled with water. Water-equivalent diameters (Dw\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$${D}_{\mathrm{w}}$$\end{document}) were calculated from the CT localizer radiographs and CT axial images. Relative errors of SSDEs from the CT localizer radiographs to SSDEs from the CT axial images were calculated to evaluate the effect of table height displacement. Furthermore, patient center deviations and indices of SSDE overestimation were measured from the clinical data of 110 abdominal CT examinations. The relative errors of SSDEs in phantoms equivalent to 1-year-old and 20-year-old Japanese reference persons ranged from − 2.45% (table height of 50 mm) to + 1.88% (− 50 mm) and from − 4.22% (50 mm) to + 3.79% (− 50 mm), respectively. The largest center deviation in all patients ranged from − 43.1 to 21.5 mm (median: − 14.4 mm). The indices of SSDE overestimation for all patients ranged from − 16.2 to 6.9 mm (median: − 2.2 mm). We found that the effects of table height displacement and patient center deviation along the z\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$z$$\end{document}-axis on SSDEs calculated from CT localizer radiographs in pediatric phantoms were smaller compared to adult phantoms. In order to correct these patient center deviations, it is necessary to apply an appropriate correction technique in each section along the z\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$z$$\end{document}-axis.
引用
收藏
页码:665 / 672
页数:7
相关论文
共 36 条
  • [1] Effect of table height displacement and patient center deviation on size-specific dose estimates calculated from computed tomography localizer radiographs
    Kuriyama, Kazuki
    Matsubara, Kosuke
    Hisahara, Shu
    Nagata, Yukie
    Nosaka, Rumiko
    Goto, Rika
    Yanano, Nobutaka
    Shimizu, Kanichiro
    Shoji, Tomokazu
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 665 - 672
  • [2] Size-specific dose estimates: Localizer or transverse abdominal computed tomography images?
    Pourjabbar, Sarvenaz
    Singh, Sarabjeet
    Padole, Atul
    Saini, Akshay
    Blake, Michael A.
    Kalra, Mannudeep K.
    WORLD JOURNAL OF RADIOLOGY, 2014, 6 (05): : 210 - 217
  • [3] Size-Specific Dose Estimates in Fetal Computed Tomography
    Kobayashi, Masanao
    Nishihara, Yusei
    Haba, Tomonobu
    Matsunaga, Yuta
    Minami, Kazuyuki
    Asada, Yasuki
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (06) : 339 - 348
  • [4] SIMPLE METHOD OF SIZE-SPECIFIC DOSE ESTIMATES CALCULATION FROM PATIENT WEIGHT ON COMPUTED TOMOGRAPHY
    Iriuchijima, Akiko
    Fukushima, Yasuhiro
    Nakajima, Takahito
    Tsushima, Yoshito
    Ogura, Akio
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (02) : 208 - 212
  • [5] Size-specific dose estimates calculated using patient size measurements from scanned projection radiograph in high-resolution chest computed tomography
    Brindhaban, Ajit
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2025, 72 (01) : 85 - 92
  • [6] Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Hanaoka, Shinsuke
    Matsubara, Kosuke
    Takata, Tadanori
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 246 - 251
  • [7] ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY
    Boos, Johannes
    Kroepil, Patric
    Bethge, Oliver Th.
    Aissa, Joel
    Schleich, Christoph
    Sawicki, Lino Morris
    Heinzler, Niklas
    Antoch, Gerald
    Thomas, Christoph
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 8 - 19
  • [8] A Segmentation-based Automated Calculation of Patient Size and Size-specific Dose Estimates in Pediatric Computed Tomography Scans
    Abdulkadir, Muhammad Kabir
    Osman, Noor Diyana
    Achuthan, Anusha
    Nasirudin, Radin A.
    Ahmad, Muhammad Zabidi
    Zain, Noor Hasyima Mat
    Shuaib, Ibrahim Lutfi
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 456 - 463
  • [9] Using a Somatosensory Controller to Assess Body Size for Size-Specific Dose Estimates in Computed Tomography
    Wu, Jay
    Han, Ruo-Ping
    Liu, Yan-Lin
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [10] Multivariate Analysis of Effective Dose and Size-Specific Dose Estimates for Thorax and Abdominal Computed Tomography
    Shah, Mudasir Ashraf
    Ahmad, Mehtab
    Khalid, Saifullah
    Qaseem, Syed M. Danish
    Siddiqui, Shaista
    Talib, Sayema
    Rather, Sajad Ahmed
    Firdous, Arfat
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (02) : 210 - 218