Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study

被引:8
|
作者
Romero, Marta [1 ]
Herrero-Climent, Mariano [1 ,2 ]
Rios-Carrasco, Blanca [1 ]
Brizuela, Aritza [3 ]
Romero, Manuel Maria [1 ]
Gil, Javier [4 ]
机构
[1] Univ Seville, Sch Dent, Dept Periodontol, C-Avicena S-N, Seville 41009, Spain
[2] Porto Dent Inst, Periodontol Dept, Symmetrya Prothesis, Ave Montevideu 810, P-4150518 Porto, Portugal
[3] Univ Europea Miguel Cervantes, Fac Ciencias Salud, Densia Reserach Grp, C Padre Julio Chevalier 2, Valladolid 47012, Spain
[4] Univ Int Catalunya, Bioengn Inst Technol, Fac Med & Hlth Sci, C Josep Trueta S-N, Sant Cugat Del Valles 08195, Barcelona, Spain
关键词
dental implant; titanium; primary stability; insertion torque; implant stability quotient; RESONANCE FREQUENCY-ANALYSIS; CRESTAL BONE CHANGES; SURFACE-ROUGHNESS; SURGICAL TECHNIQUE; TITANIUM IMPLANTS; FATIGUE; OSSEOINTEGRATION; WETTABILITY; TOPOGRAPHY; GEOMETRY;
D O I
10.3390/jcm12134190
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level. The implant surface was subjected to grit-blasting treatments with alumina particles of 120, 300, and 600 & mu;m at a projection pressure of 2.5 bar, resulting in three types of roughness. Roughness was determined via optical interferometry. The wettability of the surfaces was also determined. Implant stability was measured using a high-precision torquemeter to obtain IT, and RFA was used to determine the implant stability quotient (ISQ). The results show that rough surfaces with Sa values of 0.5 to 4 & mu;m do not affect the primary stability. However, the type of implant is important; bone-level implants obtained the highest primary stability values. A good correlation between the primary stability values obtained via IT and ISQ was demonstrated. New in vivo studies are necessary to know whether these results can be maintained in the long term.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Examination of Factor to Influence Dental Implant Stability Quotient Change
    Matsumoto, Keisuke
    Inoue, Kazuya
    Imagawa, Naoko
    Nakajima, Yoichiro
    Nakano, Hiroyuki
    Ueno, Takaaki
    JOURNAL OF HARD TISSUE BIOLOGY, 2020, 29 (02) : 131 - 134
  • [12] Macrogeometric Differentiation of Dental Implant Primary Stability: An In Vitro Study
    Al-Tarawneh, Sandra K.
    Thalji, Ghadeer
    Cooper, Lyndon F.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1110 - 1118
  • [13] Effect of Implant Length and Insertion Depth on Primary Stability of Short Dental Implant
    Wu, Hsiang-Chun
    Huang, Heng-Li
    Fuh, Lih Jyh
    Tsai, Ming Tzu
    Hsu, Jui-Ting
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (01) : 62 - 70
  • [14] Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study
    Raz, Perry
    Meir, Haya
    Levartovsky, Shifra
    Sebaoun, Alon
    Beitlitum, Ilan
    MATERIALS, 2022, 15 (09)
  • [15] Insertion torque/time integral as a measure of primary implant stability
    Grobecker-Karl, Tanja
    Karl, Matthias
    Steiner, Constanze
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2020, 65 (06): : 729 - 733
  • [16] Effect of photobiomodulation therapy of overprepared dental implant bed on torque removal and implant stability quotient: an experimental study in sheep
    Xailani, Kocher K.
    Hamad, Shehab A.
    MINERVA DENTAL AND ORAL SCIENCE, 2024, 73 (02) : 96 - 101
  • [17] The relationship between implant stability quotient values and implant insertion variables: a clinical study
    Park, K-J
    Kwon, J-Y
    Kim, S-K
    Heo, S-J
    Koak, J-Y
    Lee, J-H
    Lee, S-J
    Kim, T-H
    Kim, M-J
    JOURNAL OF ORAL REHABILITATION, 2012, 39 (02) : 151 - 159
  • [18] Influence of Bone Quality, Drilling Protocol, Implant Diameter/Length on Primary Stability: An In Vitro Comparative Study on Insertion Torque and Resonance Frequency Analysis
    Farronato, Davide
    Manfredini, Mattia
    Stocchero, Michele
    Caccia, Mattia
    Azzi, Lorenzo
    Farronato, Marco
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (03) : 182 - 189
  • [19] Development of a New Implant Primary Stability Parameter: Insertion Torque Revisited
    Degidi, Marco
    Daprile, Giuseppe
    Piattelli, Adriano
    Iezzi, Giovanna
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (05) : 637 - 644
  • [20] Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: Is there a relationship? An in vitro study
    Trisi, Paolo
    De Benedittis, Simona
    Perfetti, Giorgio
    Berardi, Davide
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) : 567 - 570