Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study

被引:8
|
作者
Romero, Marta [1 ]
Herrero-Climent, Mariano [1 ,2 ]
Rios-Carrasco, Blanca [1 ]
Brizuela, Aritza [3 ]
Romero, Manuel Maria [1 ]
Gil, Javier [4 ]
机构
[1] Univ Seville, Sch Dent, Dept Periodontol, C-Avicena S-N, Seville 41009, Spain
[2] Porto Dent Inst, Periodontol Dept, Symmetrya Prothesis, Ave Montevideu 810, P-4150518 Porto, Portugal
[3] Univ Europea Miguel Cervantes, Fac Ciencias Salud, Densia Reserach Grp, C Padre Julio Chevalier 2, Valladolid 47012, Spain
[4] Univ Int Catalunya, Bioengn Inst Technol, Fac Med & Hlth Sci, C Josep Trueta S-N, Sant Cugat Del Valles 08195, Barcelona, Spain
关键词
dental implant; titanium; primary stability; insertion torque; implant stability quotient; RESONANCE FREQUENCY-ANALYSIS; CRESTAL BONE CHANGES; SURFACE-ROUGHNESS; SURGICAL TECHNIQUE; TITANIUM IMPLANTS; FATIGUE; OSSEOINTEGRATION; WETTABILITY; TOPOGRAPHY; GEOMETRY;
D O I
10.3390/jcm12134190
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level. The implant surface was subjected to grit-blasting treatments with alumina particles of 120, 300, and 600 & mu;m at a projection pressure of 2.5 bar, resulting in three types of roughness. Roughness was determined via optical interferometry. The wettability of the surfaces was also determined. Implant stability was measured using a high-precision torquemeter to obtain IT, and RFA was used to determine the implant stability quotient (ISQ). The results show that rough surfaces with Sa values of 0.5 to 4 & mu;m do not affect the primary stability. However, the type of implant is important; bone-level implants obtained the highest primary stability values. A good correlation between the primary stability values obtained via IT and ISQ was demonstrated. New in vivo studies are necessary to know whether these results can be maintained in the long term.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] In Vitro Assessment of Primary Stability of BoneTrust Sinus Implant Design
    Gulses, Aydin
    Ayna, Mustafa
    Guclu, Hakan
    Sencimen, Metin
    Basiry, M. Nabi
    Gierloff, Matthias
    Acil, Yahya
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (05) : 731 - 735
  • [42] Effect of Different Crown Removing Procedures on the Implant Stability Quotient and Removal Torque Values of Dental Implants
    Akin, Hakan
    Unal, Yasemen
    Yilmazer, Kaan
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2021, 11 (02): : 314 - +
  • [43] Implant stability quotient and osteogenic process in dental implant sites prepared using piezoelectric technique: A study in minipigs
    Schierano, Gianmario
    Baldi, Domenico
    Peirone, Bruno
    von Degerfeld, Mitzy Mauthe
    Modica, Fabio
    Notaro, Vincenzo
    Boretto, Cecilia
    Muzio, Giuliana
    Autelli, Riccardo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,
  • [44] Multivariate study of factors influencing primary dental implant stability
    Mesa, Francisco
    Munoz, Ricardo
    Noguerol, Blas
    Luna, Juan de Dios
    Galindo, Pablo
    O'Valle, Francisco
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (02) : 196 - 200
  • [45] In-Vitro Study of Osseointegration: Evaluating the Influence of Surface Modifications on Dental Implant Stability
    Sghaireen, Mohammed G.
    Alam, Mohammad Khursheed
    Mohamedeissa, Ahmed Azhari Salih
    Kazma, Jad Moriss
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2518 - S2520
  • [46] Influence of Implant Geometry on Primary Insertion Stability and Simulated Pen-implant Bone Loss: An In Vitro Study Using Resonance Frequency Analysis and Damping Capacity Assessment
    Lachmann, Stefan
    Laval, Johannes Yves
    Axmann, Detlef
    Weber, Heiner
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (02) : 347 - 355
  • [47] Influence of acetabular cup design on the primary implant stability - An experimental and numerical analysis
    Zietz, C.
    Fritsche, A.
    Kluess, D.
    Mittelmeier, W.
    Bader, R.
    ORTHOPADE, 2009, 38 (11): : 1097 - +
  • [48] The Influence of Osteoporosis and Diabetes on Dental Implant Stability: A Pilot Study
    Sachelarie, Liliana
    Scrobota, Ioana
    Cioara, Felicia
    Ghitea, Timea Claudia
    Stefanescu, Corina Laura
    Todor, Liana
    Cicalau, Georgiana Ioana Potra
    MEDICINA-LITHUANIA, 2025, 61 (01):
  • [49] Insertion Torque Function Analysis of Novel Dental Implant Geometry
    Pammer, D.
    Bognar, E.
    FIRST EUROPEAN BIOMEDICAL ENGINEERING CONFERENCE FOR YOUNG INVESTIGATORS, 2015, 50 : 83 - 86
  • [50] Comparative Assessment of the Primary Stability of Straumann BLX Implant Design Using an In Vitro Sinus Lift- Simultaneous Implant Insertion Model
    Emmert, Marie
    Spille, Johannes
    Behrens, Eleonore
    Ayna, Mustafa
    Karayurek, Fatih
    Wiltfang, Jorg
    Acil, Yahya
    Guelses, Aydin
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (04) : 269 - 275