Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study

被引:8
|
作者
Romero, Marta [1 ]
Herrero-Climent, Mariano [1 ,2 ]
Rios-Carrasco, Blanca [1 ]
Brizuela, Aritza [3 ]
Romero, Manuel Maria [1 ]
Gil, Javier [4 ]
机构
[1] Univ Seville, Sch Dent, Dept Periodontol, C-Avicena S-N, Seville 41009, Spain
[2] Porto Dent Inst, Periodontol Dept, Symmetrya Prothesis, Ave Montevideu 810, P-4150518 Porto, Portugal
[3] Univ Europea Miguel Cervantes, Fac Ciencias Salud, Densia Reserach Grp, C Padre Julio Chevalier 2, Valladolid 47012, Spain
[4] Univ Int Catalunya, Bioengn Inst Technol, Fac Med & Hlth Sci, C Josep Trueta S-N, Sant Cugat Del Valles 08195, Barcelona, Spain
关键词
dental implant; titanium; primary stability; insertion torque; implant stability quotient; RESONANCE FREQUENCY-ANALYSIS; CRESTAL BONE CHANGES; SURFACE-ROUGHNESS; SURGICAL TECHNIQUE; TITANIUM IMPLANTS; FATIGUE; OSSEOINTEGRATION; WETTABILITY; TOPOGRAPHY; GEOMETRY;
D O I
10.3390/jcm12134190
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level. The implant surface was subjected to grit-blasting treatments with alumina particles of 120, 300, and 600 & mu;m at a projection pressure of 2.5 bar, resulting in three types of roughness. Roughness was determined via optical interferometry. The wettability of the surfaces was also determined. Implant stability was measured using a high-precision torquemeter to obtain IT, and RFA was used to determine the implant stability quotient (ISQ). The results show that rough surfaces with Sa values of 0.5 to 4 & mu;m do not affect the primary stability. However, the type of implant is important; bone-level implants obtained the highest primary stability values. A good correlation between the primary stability values obtained via IT and ISQ was demonstrated. New in vivo studies are necessary to know whether these results can be maintained in the long term.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design
    Baldi, Domenico
    Lombardi, Teresa
    Colombo, Jacopo
    Cervino, Gabriele
    Perinetti, Giuseppe
    Di Lenarda, Roberto
    Stacchi, Claudio
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [22] A simple mathematical model for the resonance frequency analysis of dental implant stability: Implant clamping quotient
    Argatov, Ivan
    Iantchenko, Alexei
    MECHANICS RESEARCH COMMUNICATIONS, 2019, 95 : 67 - 70
  • [23] Analysis of bone stress and primary stability of a dental implant using strain and torque measurements
    Nascimento, Larissa Ramos Xavier Coutinho
    Torelly, Guilherme Monteiro
    Elias, Carlos Nelson
    SAUDI DENTAL JOURNAL, 2023, 35 (03) : 263 - 269
  • [24] Influence of the dental implant macrogeometry and threads design on primary stability: an in vitro simulation on artificial bone blocks
    Comuzzi, Luca
    Tumedei, Margherita
    De Angelis, Francesco
    Lorusso, Felice
    Piattelli, Adriano
    Iezzi, Giovanna
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (11) : 1242 - 1250
  • [25] The Influence of the Implant Macrogeometry on Insertion Torque, Removal Torque, and Periotest Implant Primary Stability: A Mechanical Simulation on High-Density Artificial Bone
    Tumedei, Margherita
    Petrini, Morena
    Pietropaoli, Davide
    Cipollina, Alessandro
    La Torre, Castrenze
    Di Carmine, Maria Stella
    Piattelli, Adriano
    Iezzi, Giovanna
    SYMMETRY-BASEL, 2021, 13 (05):
  • [26] Effect of Implant Macro-Design and Magnetodynamic Surgical Preparation on Primary Implant Stability: An In Vitro Investigation
    Antonelli, Alessandro
    Barone, Selene
    Attanasio, Ferdinando
    Salviati, Marianna
    Cerra, Maria Giulia
    Calabria, Elena
    Bennardo, Francesco
    Giudice, Amerigo
    DENTISTRY JOURNAL, 2023, 11 (10)
  • [27] Insertion Torque Value and Implant Stability Quotient: Separate Evaluation and Correlation for Different Clinical Parameters
    Ferreira, Jose Joaquim Da Rocha
    Machado, Luis Filipe Meira
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 812 - 822
  • [28] Relevant Aspects of the Dental Implant Design on the Insertion Torque, Resonance Frequency Analysis (RFA) and Micromobility: An In Vitro Study
    Herrero-Climent, Mariano
    Falcao, Artur
    Tondela, Joao
    Brizuela, Aritza
    Rios-Carrasco, Blanca
    Gil, Javier
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
  • [29] IMPLANT STABILITY RELATED TO INSERTION TORQUE FORCE AND BONE-DENSITY - AN IN-VITRO STUDY
    TRICIO, J
    VANSTEENBERGHE, D
    ROSENBERG, D
    DUCHATEAU, L
    JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (06): : 608 - 612
  • [30] Influence of implant length and insertion depth on primary stability of short dental implants: An in vitro study of a novel mandibular artificial bone model
    Wu, Hsiang-Chun
    Huang, Heng-Li
    Fuh, Lih-Jyh
    Tsai, Ming-Tzu
    Hsu, Jui-Ting
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (01) : 139 - 147