Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study

被引:8
|
作者
Romero, Marta [1 ]
Herrero-Climent, Mariano [1 ,2 ]
Rios-Carrasco, Blanca [1 ]
Brizuela, Aritza [3 ]
Romero, Manuel Maria [1 ]
Gil, Javier [4 ]
机构
[1] Univ Seville, Sch Dent, Dept Periodontol, C-Avicena S-N, Seville 41009, Spain
[2] Porto Dent Inst, Periodontol Dept, Symmetrya Prothesis, Ave Montevideu 810, P-4150518 Porto, Portugal
[3] Univ Europea Miguel Cervantes, Fac Ciencias Salud, Densia Reserach Grp, C Padre Julio Chevalier 2, Valladolid 47012, Spain
[4] Univ Int Catalunya, Bioengn Inst Technol, Fac Med & Hlth Sci, C Josep Trueta S-N, Sant Cugat Del Valles 08195, Barcelona, Spain
关键词
dental implant; titanium; primary stability; insertion torque; implant stability quotient; RESONANCE FREQUENCY-ANALYSIS; CRESTAL BONE CHANGES; SURFACE-ROUGHNESS; SURGICAL TECHNIQUE; TITANIUM IMPLANTS; FATIGUE; OSSEOINTEGRATION; WETTABILITY; TOPOGRAPHY; GEOMETRY;
D O I
10.3390/jcm12134190
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level. The implant surface was subjected to grit-blasting treatments with alumina particles of 120, 300, and 600 & mu;m at a projection pressure of 2.5 bar, resulting in three types of roughness. Roughness was determined via optical interferometry. The wettability of the surfaces was also determined. Implant stability was measured using a high-precision torquemeter to obtain IT, and RFA was used to determine the implant stability quotient (ISQ). The results show that rough surfaces with Sa values of 0.5 to 4 & mu;m do not affect the primary stability. However, the type of implant is important; bone-level implants obtained the highest primary stability values. A good correlation between the primary stability values obtained via IT and ISQ was demonstrated. New in vivo studies are necessary to know whether these results can be maintained in the long term.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] The insertion torque-depth curve integral as a measure of implant primary stability: An in vitro study on polyurethane foam blocks
    Di Stefano, Danilo Alessio
    Arosio, Paolo
    Gastaldi, Giorgio
    Gherlone, Enrico
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (05): : 706 - 714
  • [32] Influence of torque and bone type on stability quotient of two implant platforms: a clinical trial
    Bannwart, Lisiane Cristina
    dos Santos, Daniela Micheline
    Souza, Joao Paulo do Vale
    Neto, Clovis Lamartine de Moraes M. E. L. O.
    da Silva, Emily Vivianne Freitas
    Mazaro, Jose Vitor Quinelli
    Salzedas, Leda Maria Piscinini
    Goiato, Marcelo Coelho
    BRAZILIAN ORAL RESEARCH, 2024, 38
  • [33] Influence of Clinical Parameters on the Primary Stability of a Tapered Dental Implant: A Retrospective Analysis
    Blume, Oliver
    Wildenhof, Jan
    Otto, Sven
    Probst, Florian A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (04) : 762 - 770
  • [34] Experimental Investigation of Vibration Analysis on Implant Stability for a Novel Implant Design
    Lu, Shouxun
    Vien, Benjamin Steven
    Russ, Matthias
    Fitzgerald, Mark
    Chiu, Wing Kong
    SENSORS, 2022, 22 (04)
  • [35] Experimental study to establishing the insertion torque on dental implant
    Isabel Lopez-Gualdron, Clara
    Fernando Galeano-Arrieta, Carlos
    Cesar Pinillos, Julio
    Carlos Moreno, Juan
    REVISTA ITECKNE, 2014, 11 (01): : 17 - 26
  • [36] In Vitro Investigation of the Dependency Between Abutment Length and Implant Stability Quotient (ISQ) for Stability Measurements on Bone Anchored Hearing Implant Systems
    Hogsbro, Morten
    Agger, Andreas
    Johansen, Lars Vendelbo
    Gaihede, Michael
    OTOLOGY & NEUROTOLOGY, 2020, 41 (06) : 848 - 854
  • [37] Investigation of Implant Stability Quotient Values of Dental Implants Placed in Vascularized Bone Grafts
    Matsumoto, Keisuke
    Mano, Takamitsu
    Inoue, Kazuya
    Yamamoto, Kayoko
    Imagawa, Naoko
    Takahashi, Ayaka
    Ueno, Takaaki
    JOURNAL OF HARD TISSUE BIOLOGY, 2022, 31 (01) : 55 - 58
  • [38] Reliability of the Osstell Implant Stability Quotient and Penguin Resonance Frequency Analysis to Evaluate Implant Stability
    Buyukguclu, Gul
    Ozkurt-Kayahan, Zeynep
    Kazazoglu, Ender
    IMPLANT DENTISTRY, 2018, 27 (04) : 429 - 433
  • [39] ASSESSMENT OF IN VITRO DENTAL IMPLANT PRIMARY STABILITY USING AN ULTRASONIC METHOD
    Vayron, Romain
    Mathieu, Vincent
    Michel, Adrien
    Haiat, Guillaume
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (12): : 2885 - 2894
  • [40] ULTRASONIC EVALUATION OF DENTAL IMPLANT BIOMECHANICAL STABILITY: AN IN VITRO STUDY
    Mathieu, Vincent
    Anagnostou, Fani
    Soffer, Emmanuel
    Haiat, Guillaume
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (02): : 262 - 270