Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study

被引:4
|
作者
Raz, Perry [1 ]
Meir, Haya [1 ]
Levartovsky, Shifra [2 ]
Sebaoun, Alon [1 ]
Beitlitum, Ilan [1 ]
机构
[1] Tel Aviv Univ, Sackler Fac Med, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Periodontol & Dent Implants, IL-6139001 Tel Aviv, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Oral Rehabil, IL-6139001 Tel Aviv, Israel
关键词
primary stability; implant stability; ISQ; RFA; insertion torque; implant design; bone density; RESONANCE-FREQUENCY-ANALYSIS; INSERTION TORQUE; BIOMECHANICAL ASPECTS; MAXILLARY; GEOMETRY;
D O I
10.3390/ma15093072
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Primary implant stability can be evaluated at the time of placement by measuring the insertion torque (IT). However, another method to monitor implant stability over time is resonance frequency analysis (RFA). Our aim was to examine the effect of bone type, implant design, and implant length on implant primary stability as measured by IT and two RFA devices (Osstell and Penguin) in an in vitro model. Ninety-six implants were inserted by a surgical motor in an artificial bone material, resembling soft and dense bone. Two different implant designs-conical connection (CC) and internal hex (IH), with lengths of 13 and 8 mm, were compared. The results indicate that the primary stability as measured by RFA and IT is significantly increased by the quality of bone (dense bone), and implant length and design, where the influence of dense bone is similar to that of CC design. Both the Osstell and Penguin devices recorded higher primary implant stability for long implants in dense bone, favoring the CC over the IH implant design. The CC implant design may compensate for the low stability expected in soft bone, and dense bone may compensate for short implant length if required by the anatomical bone conditions.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
    David E. Simmons
    Pooja Maney
    Austin G. Teitelbaum
    Susan Billiot
    Lomesh J. Popat
    A. Archontia Palaiologou
    [J]. International Journal of Implant Dentistry, 3
  • [2] Evaluation of Biomechanical and Stress Distribution of Different Dental Implant Designs: Primary Stability and Photoelastic Analysis
    Tardelli, J. D. C.
    Macedo, A. P.
    Valente, da Costa
    [J]. IRBM, 2022, 43 (02) : 100 - 106
  • [3] Macrogeometric Differentiation of Dental Implant Primary Stability: An In Vitro Study
    Al-Tarawneh, Sandra K.
    Thalji, Ghadeer
    Cooper, Lyndon F.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1110 - 1118
  • [4] In Vitro Assessment of Primary Stability of Straumann® Implant Designs
    Romanos, Georgios E.
    Ciornei, Gabriela
    Jucan, Adina
    Malmstrom, Hans
    Gupta, Bhumija
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (01) : 89 - 95
  • [5] Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study
    Bilhan, Hakan
    Bilmenoglu, Caglar
    Urgun, Aliye Ceren
    Ates, Gokcen
    Bural, Canan
    Cilingir, Altug
    Geckili, Onur
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (05) : 1036 - 1040
  • [6] Comparative evaluation of the stability of two different dental implant designs and surgical protocols-a pilot study
    Simmons, David E.
    Maney, Pooja
    Teitelbaum, Austin G.
    Billiot, Susan
    Popat, Lomesh J.
    Palaiologou, A. Archontia
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2017, 3
  • [7] Comparison of histomorphometry and microradiography of different implant designs to assess primary implant stability
    Romanos, Georgios
    Damouras, Michael
    Veis, Alexander A.
    Hess, Pablo
    Schwarz, Frank
    Brandt, Silvia
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (03) : 373 - 379
  • [8] Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study
    Lee, Jungwon
    Lim, Young-Jun
    Ahn, Jin-Soo
    Kim, Bongju
    Baek, Yeon-Wha
    Lim, Bum-Soon
    [J]. PLOS ONE, 2024, 19 (05):
  • [9] Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study
    Romero, Marta
    Herrero-Climent, Mariano
    Rios-Carrasco, Blanca
    Brizuela, Aritza
    Romero, Manuel Maria
    Gil, Javier
    [J]. JOURNAL OF CLINICAL MEDICINE, 2023, 12 (13)
  • [10] Primary stability of implant placement and loading related to dental implant materials and designs: A literature review
    Huang, Yu-Che
    Huang, Yen-Chang
    Ding, Shinn-Jyh
    [J]. JOURNAL OF DENTAL SCIENCES, 2023, 18 (04) : 1467 - 1476