Examination of Factor to Influence Dental Implant Stability Quotient Change

被引:2
|
作者
Matsumoto, Keisuke [1 ]
Inoue, Kazuya [1 ]
Imagawa, Naoko [1 ]
Nakajima, Yoichiro [1 ]
Nakano, Hiroyuki [1 ]
Ueno, Takaaki [1 ]
机构
[1] Osaka Med Coll, Dept Dent & Oral Surg, Div Med Funct & Morphol Sensory Organs, Fac Med, 2-7 Daigaku Machi, Takatsuki, Osaka 5698686, Japan
关键词
Dental implant; Implant safety quotient; Implant safety quotient change; INSERTION TORQUE; FREQUENCY; MAXILLARY;
D O I
10.2485/jhtb.29.131
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The success rate of dental implants depends largely on osseointegration of the implant. One method for evaluating osseointegration that has garnered attention is measurement of the implant safety quotient (ISQ) using resonance frequency analysis, but there have been few studies that have observed chronological changes in ISQ in the same implant type. Here, we observed chronological changes in ISQ in high-temperature acid-etched implants. The implants that were studied were 43 Swiss Precision and Innovation implants (SPI (R) implant, Thommen Medical, Grenchen, Switzerland) with a diameter of 4.0 mm that were placed at our clinic in 2017-2018 by the same technician. ISQ was measured at primary and secondary surgery using an Osstell IDx tooth contact analysis device (Osstell AB, Gothenburg, Sweden). Secondary surgery was carried out 6 months after placement in the maxilla and 3 months after placement in the mandible. The ISQ and change in ISQ thus obtained were investigated by placement site. ISQ at primary surgery was significantly higher in the mandible than the maxilla (p<0.001). Change in ISQ from primary to secondary surgery tended to be greater in the maxillary anterior tooth region and the maxillary molar region than the mandibular anterior tooth region and the mandibular molar region. By comparing ISQ from primary to secondary surgery using a single implant type, it was observed that ISQ and change in ISQ varied according to placement site.
引用
收藏
页码:131 / 134
页数:4
相关论文
共 50 条
  • [1] Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study
    Romero, Marta
    Herrero-Climent, Mariano
    Rios-Carrasco, Blanca
    Brizuela, Aritza
    Romero, Manuel Maria
    Gil, Javier
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (13)
  • [2] A simple mathematical model for the resonance frequency analysis of dental implant stability: Implant clamping quotient
    Argatov, Ivan
    Iantchenko, Alexei
    MECHANICS RESEARCH COMMUNICATIONS, 2019, 95 : 67 - 70
  • [3] Influence of formalin fixation on the implant stability quotient and mechanical characteristics of bone
    Morita, Koji
    Doi, Kazuya
    Oue, Hiroshi
    Kajihara, Shiho
    Hayashi, Kazuhiko
    Akagawa, Yasumasa
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2013, 51 (06): : 550 - 554
  • [4] Investigation of Implant Stability Quotient Values of Dental Implants Placed in Vascularized Bone Grafts
    Matsumoto, Keisuke
    Mano, Takamitsu
    Inoue, Kazuya
    Yamamoto, Kayoko
    Imagawa, Naoko
    Takahashi, Ayaka
    Ueno, Takaaki
    JOURNAL OF HARD TISSUE BIOLOGY, 2022, 31 (01) : 55 - 58
  • [5] Implant stability quotient and osteogenic process in dental implant sites prepared using piezoelectric technique: A study in minipigs
    Schierano, Gianmario
    Baldi, Domenico
    Peirone, Bruno
    von Degerfeld, Mitzy Mauthe
    Modica, Fabio
    Notaro, Vincenzo
    Boretto, Cecilia
    Muzio, Giuliana
    Autelli, Riccardo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,
  • [6] Effect of photobiomodulation therapy of overprepared dental implant bed on torque removal and implant stability quotient: an experimental study in sheep
    Xailani, Kocher K.
    Hamad, Shehab A.
    MINERVA DENTAL AND ORAL SCIENCE, 2024, 73 (02) : 96 - 101
  • [7] Influence of immediate loading on provisional restoration in dental implant stability
    Ikbal, M.
    Odang, R. W.
    Indrasari, M.
    Dewi, R. S.
    1ST PHYSICS AND TECHNOLOGIES IN MEDICINE AND DENTISTRY SYMPOSIUM, 2017, 884
  • [8] Analyzing the Influence of a New Dental Implant Design on Primary Stability
    da Costa Valente, Mariana Lima
    de Castro, Denise Tornavoi
    Shimano, Antonio Carlos
    Lepri, Cesar Penazzo
    dos Reis, Andrea Candido
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 168 - 173
  • [9] Influence of periosteal coverage on the osteointegration and stability of dental implant distractors
    Yin, Xuelai
    Zhang, Chenping
    Hze-Khoong, Eugene Poh
    Shen, Shunkun
    Xu, Liqun
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (07) : 826 - 830
  • [10] The Influence of Osteoporosis and Diabetes on Dental Implant Stability: A Pilot Study
    Sachelarie, Liliana
    Scrobota, Ioana
    Cioara, Felicia
    Ghitea, Timea Claudia
    Stefanescu, Corina Laura
    Todor, Liana
    Cicalau, Georgiana Ioana Potra
    MEDICINA-LITHUANIA, 2025, 61 (01):