Examination of Factor to Influence Dental Implant Stability Quotient Change

被引:2
|
作者
Matsumoto, Keisuke [1 ]
Inoue, Kazuya [1 ]
Imagawa, Naoko [1 ]
Nakajima, Yoichiro [1 ]
Nakano, Hiroyuki [1 ]
Ueno, Takaaki [1 ]
机构
[1] Osaka Med Coll, Dept Dent & Oral Surg, Div Med Funct & Morphol Sensory Organs, Fac Med, 2-7 Daigaku Machi, Takatsuki, Osaka 5698686, Japan
关键词
Dental implant; Implant safety quotient; Implant safety quotient change; INSERTION TORQUE; FREQUENCY; MAXILLARY;
D O I
10.2485/jhtb.29.131
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The success rate of dental implants depends largely on osseointegration of the implant. One method for evaluating osseointegration that has garnered attention is measurement of the implant safety quotient (ISQ) using resonance frequency analysis, but there have been few studies that have observed chronological changes in ISQ in the same implant type. Here, we observed chronological changes in ISQ in high-temperature acid-etched implants. The implants that were studied were 43 Swiss Precision and Innovation implants (SPI (R) implant, Thommen Medical, Grenchen, Switzerland) with a diameter of 4.0 mm that were placed at our clinic in 2017-2018 by the same technician. ISQ was measured at primary and secondary surgery using an Osstell IDx tooth contact analysis device (Osstell AB, Gothenburg, Sweden). Secondary surgery was carried out 6 months after placement in the maxilla and 3 months after placement in the mandible. The ISQ and change in ISQ thus obtained were investigated by placement site. ISQ at primary surgery was significantly higher in the mandible than the maxilla (p<0.001). Change in ISQ from primary to secondary surgery tended to be greater in the maxillary anterior tooth region and the maxillary molar region than the mandibular anterior tooth region and the mandibular molar region. By comparing ISQ from primary to secondary surgery using a single implant type, it was observed that ISQ and change in ISQ varied according to placement site.
引用
收藏
页码:131 / 134
页数:4
相关论文
共 50 条
  • [21] Insertion Torque (IT) and Implant Stability Quotient (ISQ) Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study
    Mello, Bruno Freitas
    Formiga, Marcio De Carvalho
    Bianchini, Marco Aurelio
    Borges Jr, Ivan
    Coura, Gustavo
    Tumedei, Margherita
    Fuller, Renato
    Petrini, Morena
    Romasco, Tea
    Vaz, Paula
    Piattelli, Adriano
    Di Pietro, Natalia
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [22] EVALUATION OF DENTAL IMPLANT STABILITY IN SMOKERS
    Pirayvatlou, S. S.
    ANNALS OF DENTAL SPECIALTY, 2018, 6 (01): : 23 - 25
  • [23] Temperature change of dental implant drills
    Tanyel, C.
    Gunay, A.
    Cankaya, B.
    Gencel, B.
    Ozdal, O.
    Katiboglu, A. B.
    ORAL DISEASES, 2014, 20 : 11 - 11
  • [24] Implant Stability Quotient (ISQ) from surgery to prosthetic rehabilitation
    Sampaio-Fernandes, Manuel A.
    Pimentel, Luis Guilherme
    Marques, Nuno Mesquita
    Fernandes, Pedro Ferras
    Almeida, Paulo Julio
    Sampaio-Fernandes, Joao C.
    BIODENTAL ENGINEERING IV, 2018, : 21 - 24
  • [25] Specific use of the implant stability quotient as a guide to improve healing for patients who had undergone rehabilitation with fixed implant-supported dental prostheses
    Trasarti, Stefano
    Toti, Paolo
    Covani, Ugo
    Crespi, Roberto
    Menchini-Fabris, Giovanni-Battista
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (05)
  • [26] Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value
    Yoon, Hong-Gi
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    Lee, Su-Young
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (01): : 10 - 15
  • [27] A Comparison between the Implant Stability Quotient and the Fractal Dimension of Alveolar Bone at the Implant Site
    Kulczyk, Tomasz
    Czajka-Jakubowska, Agata
    Przystanska, Agnieszka
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [28] Correlation Between Implant Stability Quotient and Percussion Sound Frequency
    Peeraprasompong, Wansiri
    Aunmeungtong, Weerapan
    Khongkhunthian, Pathawee
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (04):
  • [29] The relationship between implant stability quotient values and implant insertion variables: a clinical study
    Park, K-J
    Kwon, J-Y
    Kim, S-K
    Heo, S-J
    Koak, J-Y
    Lee, J-H
    Lee, S-J
    Kim, T-H
    Kim, M-J
    JOURNAL OF ORAL REHABILITATION, 2012, 39 (02) : 151 - 159
  • [30] Correlation Between Acquisition of Dental Implant Stability and Hounsfield Units at Dental Implant Placement
    Takekawa, Takahiro
    Moroi, Akinori
    Gomi, Karen
    Takayama, Akihiro
    Yoshizawa, Kunio
    Ueki, Koichiro
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (01) : 24 - 30