Insertion Torque (IT) and Implant Stability Quotient (ISQ) Assessment in Dental Implants with and without Healing Chambers: A Polyurethane In Vitro Study

被引:4
|
作者
Mello, Bruno Freitas [1 ]
Formiga, Marcio De Carvalho [1 ]
Bianchini, Marco Aurelio [2 ]
Borges Jr, Ivan [1 ]
Coura, Gustavo [1 ]
Tumedei, Margherita [3 ]
Fuller, Renato [1 ]
Petrini, Morena [4 ]
Romasco, Tea [4 ,5 ]
Vaz, Paula [6 ]
Piattelli, Adriano [7 ,8 ]
Di Pietro, Natalia [4 ,5 ]
机构
[1] Unisul Univ, Dept Periodontol & Oral Implantol, BR-88101001 Florianopolis, Brazil
[2] Fed Univ Santa Catarina UFSC, Postgrad Program Implant Dent PPGO, BR-88040900 Florianopolis, Brazil
[3] Univ Milan, Dept Med Surg & Dent Sci, I-20122 Milan, Italy
[4] G dAnnunzio Univ Chieti Pescara, Dept Med Oral & Biotechnol Sci, I-66013 Chieti, Italy
[5] G dAnnunzio Univ Chieti Pescara, Ctr Adv Studies & Technol CAST, I-66013 Chieti, Italy
[6] Univ Porto, Genet Fac Dent Med, Fixed Prosthodont, P-4200393 Porto, Portugal
[7] St Camillus Int Univ Hlth & Med Sci, Sch Dent, I-00131 Rome, Italy
[8] UCAM Univ Catolica San Antonio Murcia, Fac Med, Murcia 30107, Spain
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 18期
关键词
dental implants; healing chambers; implant primary stability; insertion torque; polyurethane; removal torque; OSSEOINTEGRATION; DESIGN; MACROGEOMETRY; VIVO;
D O I
10.3390/app131810215
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Primary Stability (PS) depends on different factors, such as bone structure (quality and density), implant characteristics (macro and micro), and the relationship between thread shape and implant insertion hole size. PS is crucial for the prognosis and success of dental implants. The use of healing chambers, which create empty spaces between the implant and peri-implant bone, helps reduce the risk of compressive bone necrosis. High Insertion Torque (IT) values could potentially lead to the deterioration of the implant-abutment connection. However, the optimal implant macro-structure and IT values remain unknown. In this study, implants with healing chambers (Test) and without (Control) were inserted into polyurethane blocks with densities of 10, 20, 30, and 40 pounds per cubic foot (PCF). In blocks with densities of 30 and 40 PCF, Control implants had significantly higher IT values than Test implants. Additionally, Control implants exhibited significantly higher Removal Torque (RT) values than Test implants, but only in the 30 PCF density block (p < 0.0001). However, no differences were found between the implants in the 10, 20, and 40 PCF density blocks. Similarly, no significant differences were observed in the Implant Stability Quotient (ISQ) values between the Test and Control implants. The results of the present study confirm that adding healing chambers to the macro-structure of dental implants can significantly reduce IT values without affecting ISQ values. This suggests the potential for avoiding compression and damage to peri-implant bone while maintaining consistent levels of PS.
引用
收藏
页数:14
相关论文
共 32 条
  • [1] Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study
    Romero, Marta
    Herrero-Climent, Mariano
    Rios-Carrasco, Blanca
    Brizuela, Aritza
    Romero, Manuel Maria
    Gil, Javier
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (13)
  • [2] Effect of Different Crown Removing Procedures on the Implant Stability Quotient and Removal Torque Values of Dental Implants
    Akin, Hakan
    Unal, Yasemen
    Yilmazer, Kaan
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2021, 11 (02): : 314 - +
  • [3] Are the Insertion Torque Value and Implant Stability Quotient Correlated, and If So, Can Insertion Torque Values Predict Secondary Implant Stability? A Prospective Parallel Cohort Study
    Cassetta, Michele
    Brandetti, Giulia
    Altieri, Federica
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 135 - 142
  • [4] Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design
    Baldi, Domenico
    Lombardi, Teresa
    Colombo, Jacopo
    Cervino, Gabriele
    Perinetti, Giuseppe
    Di Lenarda, Roberto
    Stacchi, Claudio
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [5] Insertion Torque, Removal Torque, and Resonance Frequency Analysis Values of Ultrashort, Short, and Standard Dental Implants: An In Vitro Study on Polyurethane Foam Sheets
    Comuzzi, Luca
    Tumedei, Margherita
    Romasco, Tea
    Petrini, Morena
    Afrashtehfar, Kelvin I.
    Inchingolo, Francesco
    Piattelli, Adriano
    Di Pietro, Natalia
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (01)
  • [6] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: An in-vitro study
    Rismanchian M.
    Afshari M.
    Afshari, Mojtaba (Afshari.m1989@gmail.com), 1600, Inderscience Publishers (34): : 319 - 333
  • [7] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: an in-vitro study
    Rismanchian, Mansour
    Afshari, Mojtaba
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2020, 34 (04) : 319 - 333
  • [8] The insertion torque-depth curve integral as a measure of implant primary stability: An in vitro study on polyurethane foam blocks
    Di Stefano, Danilo Alessio
    Arosio, Paolo
    Gastaldi, Giorgio
    Gherlone, Enrico
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (05): : 706 - 714
  • [9] Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants
    Kahraman, S.
    Bal, B. T.
    Asar, N. V.
    Turkyilmaz, I.
    Tozum, T. F.
    JOURNAL OF ORAL REHABILITATION, 2009, 36 (10) : 755 - 761
  • [10] Effect of photobiomodulation therapy of overprepared dental implant bed on torque removal and implant stability quotient: an experimental study in sheep
    Xailani, Kocher K.
    Hamad, Shehab A.
    MINERVA DENTAL AND ORAL SCIENCE, 2024, 73 (02) : 96 - 101