FAILURE OF AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR TO REDETECT VENTRICULAR-FIBRILLATION IN PATIENTS WITH A NONTHORACOTOMY LEAD SYSTEM

被引:56
|
作者
JUNG, W [1 ]
MANZ, M [1 ]
MOOSDORF, R [1 ]
LUDERITZ, B [1 ]
机构
[1] UNIV BONN,DEPT CARDIOVASC SURG,W-5300 BONN 1,GERMANY
关键词
IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; LEAD SYSTEMS; NONTHORACOTOMY; SUDDEN CARDIAC DEATH; ELECTROGRAM; ENDOCARDIAL;
D O I
10.1161/01.CIR.86.4.1217
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Shock delivery of an implantable defibrillator may cause a change in the amplitude of endocardial electrograms and impair the detection of ventricular fibrillation. Thus, the effects of shock discharges on the amplitude of endocardial electrograms were evaluated in five patients undergoing implantation of a cardioverter-defibrillator in combination with a new nonthoracotomy lead system. Methods and Results. At implant, bipolar endocardial electrograms were recorded before each shock application, during ventricular fibrillation, during redetection of ventricular fibrillation in case the applied shock was ineffective, and at intervals of 5, 10, 20, 30, 60, and 120 seconds after each shock delivery. The amplitude of the endocardial electrograms decreased from 10.5+/-3.8 mV during sinus rhythm to 6.3+/-1.9 mV during initial ventricular fibrillation and declined to 2.2+/-1.3 mV during redetection of ventricular fibrillation. After successful termination, the following bipolar electrograms could be obtained at the predetermined intervals: 1.9+/-1.2 mV, 3.1+/-1.8 mV, 4.5+/-1.9 mV, 6.5+/-2.9 mV, 9.5+/-3.3 mV, and 10.4+/-3.8 mV. At predischarge testing, failure of redetection of ventricular fibrillation could be documented in two patients, requiring rescue external defibrillation in both cases to restore sinus rhythm. Conclusions. These findings demonstrate that the implantable cardioverter-defibrillator did not ensure reliable redetection of ventricular fibrillation in patients using the implanted nonthoracotomy lead system. Thus, the potential risk of sudden cardiac death may persist in these patients despite defibrillator therapy.
引用
收藏
页码:1217 / 1222
页数:6
相关论文
共 50 条
  • [21] Implantable cardioverter-defibrillator lead failure: how weak is the link?
    Brinker, Jeffrey A.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (12): : 758 - 759
  • [22] APPROPRIATE SENSING OF VENTRICULAR-FIBRILLATION AFTER FAILED SHOCKS IN A TRANSVENOUS CARDIOVERTER-DEFIBRILLATOR SYSTEM
    ELLIS, JR
    MARTIN, DT
    VENDITTI, FJ
    CIRCULATION, 1994, 90 (04) : 1820 - 1825
  • [23] Implantable cardioverter-defibrillator lead failure: how weak is the link?
    Jeffrey A Brinker
    Nature Clinical Practice Cardiovascular Medicine, 2008, 5 : 758 - 759
  • [24] VENTRICULAR-FIBRILLATION IN PATIENTS WITHOUT SIGNIFICANT STRUCTURAL HEART-DISEASE - A MULTICENTER EXPERIENCE WITH IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY
    MEISSNER, MD
    LEHMANN, MH
    STEINMAN, RT
    MOSTELLER, RD
    AKHTAR, M
    CALKINS, H
    CANNOM, DS
    EPSTEIN, AE
    FOGOROS, RN
    LIEM, LB
    MARCHLINSKI, FE
    MYERBURG, RJ
    VELTRI, EP
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (06) : 1406 - 1412
  • [25] Right ventricular pacing and the risk of heart failure in implantable cardioverter-defibrillator patients
    Smit, Marcelle D.
    Van Dessel, Pascal F. H. M.
    Nieuwland, Wybe
    Wiesfeld, Ans C. P.
    Tan, Eng S.
    Anthonio, Rutger L.
    Van Erven, Lieselot
    Van Veldhuisen, Dirk J.
    Van Gelder, Isabelle C.
    HEART RHYTHM, 2006, 3 (12) : 1397 - 1403
  • [26] EPICARDIAL AND NONTHORACOTOMY DEFIBRILLATION LEAD SYSTEMS COMBINED WITH A CARDIOVERTER-DEFIBRILLATOR
    TRAPPE, HJ
    FIEGUTH, HG
    PFITZNER, P
    HEINTZE, J
    WENZLAFF, P
    KIELBLOCK, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (01): : 127 - 132
  • [27] UNIPOLAR PACER ARTIFACTS INDUCED FAILURE OF AN AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR TO DETECT VENTRICULAR-FIBRILLATION
    KIM, SG
    FURMAN, S
    WASPE, LE
    BRODMAN, R
    FISHER, JD
    AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (10): : 880 - 881
  • [28] First ventricular fibrillation event in patients with Brugada syndrome treated with an implantable cardioverter-defibrillator
    Brugada, J
    Bartholomay, E
    Mont, L
    Brugada, R
    Brugada, P
    CIRCULATION, 2004, 110 (17) : 625 - 625
  • [29] SHOCK DELIVERED BY AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN RESPONSE TO SPONTANEOUS VENTRICULAR FIBRILLATION
    ROELKE, M
    ONUNAIN, SS
    NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (13): : 860 - 860
  • [30] High failure rate for an epicardial implantable cardioverter-defibrillator lead: Implications for long-term follow-up of patients with an implantable cardioverter-defibrillator
    Brady, PA
    Friedman, PA
    Trusty, JM
    Grice, S
    Hammill, SC
    Stanton, MS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) : 616 - 622