Implantable cardioverter-defibrillator lead failure: how weak is the link?

被引:5
|
作者
Brinker, Jeffrey A. [1 ]
机构
[1] Johns Hopkins Med Inst, Baltimore, MD 21205 USA
来源
关键词
arrhythmias; implantable cardioverter-defibrillator; lead failure; sudden cardiac death;
D O I
10.1038/ncpcardio1367
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The implantable cardioverter-defibrillator (ICD) has been shown to decrease the risk of sudden cardiac death in patients when used for primary and secondary prevention. These devices are being used more frequently as indications for primary prevention broaden, and attention has become increasingly focused on complications caused by lead failure. A report using data from a large registry revealed that the cumulative incidence of lead malfunction that necessitated surgical revision of the ICD lead system was 2.5% over 5 years. A strategy to deal with failed leads by the implantation of new pace-sense leads or high-voltage leads resulted in a 20% malfunction recurrence rate at 5 years. Defibrillator leads have been termed the 'weakest link' in the ICD system. Further efforts from manufacturers, regulators, and implanting physicians are required to understand and address the causes of lead failure.
引用
收藏
页码:758 / 759
页数:2
相关论文
共 50 条
  • [1] Implantable cardioverter-defibrillator lead failure: how weak is the link?
    Jeffrey A Brinker
    Nature Clinical Practice Cardiovascular Medicine, 2008, 5 : 758 - 759
  • [2] Management of the Patient With Implantable Cardioverter-Defibrillator Lead Failure
    Kalahasty, Gautham
    Ellenbogen, Kenneth A.
    CIRCULATION, 2011, 123 (12) : 1352 - 1354
  • [3] Lead failure in an entirely subcutaneous implantable cardioverter-defibrillator
    Kolb, Christof
    Weigand, Severin
    Schaarschmidt, Claudia
    Lennerz, Carsten
    EUROPACE, 2020, 22 (02): : 183 - 183
  • [4] An algorithm to predict implantable cardioverter-defibrillator lead failure
    Gunderson, BD
    Patel, AS
    Bounds, CA
    Shepard, RK
    Wood, MA
    Ellenbogen, KA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (09) : 1898 - 1902
  • [5] Implantable cardioverter-defibrillator lead performance
    Maisel, William H.
    Kramer, Daniel B.
    CIRCULATION, 2008, 117 (21) : 2721 - 2723
  • [6] Implantable Cardioverter-Defibrillator Lead Failure in Children and Young Adults
    Janson, Christopher M.
    Patel, Akash R.
    Bonney, William J.
    Smoots, Karen
    Shah, Maully J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (02) : 133 - 140
  • [7] Failure of implantable cardioverter-defibrillator leads: A matter of lead size?
    Rordorf, Roberto
    Poggio, Luca
    Savastano, Simone
    Vicentini, Alessandro
    Petracci, Barbara
    Chieffo, Enrico
    Klersy, Catherine
    Landolina, Maurizio
    HEART RHYTHM, 2013, 10 (02) : 184 - 190
  • [8] Pacemaker/implantable cardioverter-defibrillator problem: Right ventricular lead missensing in a biventricular implantable cardioverter-defibrillator
    Otten, Richard F.
    Foreman, Lynne D.
    Groh, William J.
    HEART RHYTHM, 2008, 5 (01) : 158 - 159
  • [9] Performance of an implantable cardioverter-defibrillator lead family
    Klampfleitner, Stefanie
    Mundel, Markus
    Schinke, Karin
    Neuberger, Hans-Ruprecht
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (03) : 700 - 709
  • [10] Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure
    Gunderson, BD
    Gillberg, JM
    Wood, MA
    Vijayaraman, P
    Shepard, RK
    Elenbogen, KA
    HEART RHYTHM, 2006, 3 (02) : 155 - 162