FAILURE OF AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR TO REDETECT VENTRICULAR-FIBRILLATION IN PATIENTS WITH A NONTHORACOTOMY LEAD SYSTEM

被引:56
|
作者
JUNG, W [1 ]
MANZ, M [1 ]
MOOSDORF, R [1 ]
LUDERITZ, B [1 ]
机构
[1] UNIV BONN,DEPT CARDIOVASC SURG,W-5300 BONN 1,GERMANY
关键词
IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; LEAD SYSTEMS; NONTHORACOTOMY; SUDDEN CARDIAC DEATH; ELECTROGRAM; ENDOCARDIAL;
D O I
10.1161/01.CIR.86.4.1217
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Shock delivery of an implantable defibrillator may cause a change in the amplitude of endocardial electrograms and impair the detection of ventricular fibrillation. Thus, the effects of shock discharges on the amplitude of endocardial electrograms were evaluated in five patients undergoing implantation of a cardioverter-defibrillator in combination with a new nonthoracotomy lead system. Methods and Results. At implant, bipolar endocardial electrograms were recorded before each shock application, during ventricular fibrillation, during redetection of ventricular fibrillation in case the applied shock was ineffective, and at intervals of 5, 10, 20, 30, 60, and 120 seconds after each shock delivery. The amplitude of the endocardial electrograms decreased from 10.5+/-3.8 mV during sinus rhythm to 6.3+/-1.9 mV during initial ventricular fibrillation and declined to 2.2+/-1.3 mV during redetection of ventricular fibrillation. After successful termination, the following bipolar electrograms could be obtained at the predetermined intervals: 1.9+/-1.2 mV, 3.1+/-1.8 mV, 4.5+/-1.9 mV, 6.5+/-2.9 mV, 9.5+/-3.3 mV, and 10.4+/-3.8 mV. At predischarge testing, failure of redetection of ventricular fibrillation could be documented in two patients, requiring rescue external defibrillation in both cases to restore sinus rhythm. Conclusions. These findings demonstrate that the implantable cardioverter-defibrillator did not ensure reliable redetection of ventricular fibrillation in patients using the implanted nonthoracotomy lead system. Thus, the potential risk of sudden cardiac death may persist in these patients despite defibrillator therapy.
引用
收藏
页码:1217 / 1222
页数:6
相关论文
共 50 条
  • [31] Failure to Terminate Ventricular Fibrillation With Multiple Implantable Cardioverter-Defibrillator Shocks Caused by Shock Polarity
    Thomas, George
    Cheung, Jim W.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2024, 10 (03) : 611 - 619
  • [32] Prognostic Importance of Atrial Fibrillation in Implantable Cardioverter-Defibrillator Patients
    Borleffs, C. Jan Willem
    van Rees, Johannes B.
    van Welsenes, Guido H.
    van der Velde, Enno T.
    van Erven, Lieselot
    Bax, Jeroen J.
    Schalij, Martin J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (09) : 879 - 885
  • [33] TRANSVENOUS-SUBCUTANEOUS LEAD SYSTEM FOR IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    HIEF, C
    PODCZECK, A
    VEIT, F
    FROHNER, K
    KALTENBRUNNER, W
    NURNBERG, M
    STEINBACH, K
    WIENER KLINISCHE WOCHENSCHRIFT, 1993, 105 (01) : 12 - 16
  • [34] Lead system causing twiddler's syndrome in patients with an implantable cardioverter-defibrillator
    Bracke, F
    van Gelder, B
    Dijkman, B
    Meijer, A
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (01): : 231 - 232
  • [35] Celivarone in patients with an implantable cardioverter-defibrillator: Adjunctive therapy for the reduction of ventricular arrhythmia-triggered implantable cardioverter-defibrillator interventions
    Gojkovic, Olivera
    Aliot, Etienne M.
    Capucci, Alessandro
    Connolly, Stuart J.
    Crijns, Harry
    Hohnloser, Stefan H.
    Kulakowski, Piotr
    Roy, Denis
    Radzik, David
    Singh, Bramah N.
    Kowey, Peter R.
    HEART RHYTHM, 2012, 9 (02) : 217 - U2
  • [36] Right ventricular pacing is an independent predictor for ventricular tachycardia/ventricular fibrillation occurrence and heart failure events in patients with an implantable cardioverter-defibrillator
    Gardiwal, Ajmal
    Yu, Hong
    Oswald, Hanno
    Luesebrink, Ulrich
    Ludwig, Andreas
    Pichlmaier, Andreas Maximilian
    Drexler, Helmut
    Klein, Gunnar
    EUROPACE, 2008, 10 (03): : 356 - 361
  • [37] Performance of an implantable cardioverter-defibrillator lead family
    Klampfleitner, Stefanie
    Mundel, Markus
    Schinke, Karin
    Neuberger, Hans-Ruprecht
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (03) : 700 - 709
  • [38] Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure
    Gunderson, BD
    Gillberg, JM
    Wood, MA
    Vijayaraman, P
    Shepard, RK
    Elenbogen, KA
    HEART RHYTHM, 2006, 3 (02) : 155 - 162
  • [39] Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure
    Hauser, Robert G.
    Hayes, David L.
    HEART RHYTHM, 2009, 6 (05) : 605 - 610
  • [40] HIGH FAILURE RATE FOR A CHRONIC EPICARDIAL IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEAD
    BRADY, P
    FRIEDMAN, PA
    TRUSTY, JM
    GRICE, SE
    HAMMILL, SC
    STANTON, MS
    CIRCULATION, 1995, 92 (08) : 716 - 716