High failure rate for an epicardial implantable cardioverter-defibrillator lead: Implications for long-term follow-up of patients with an implantable cardioverter-defibrillator

被引:43
|
作者
Brady, PA [1 ]
Friedman, PA [1 ]
Trusty, JM [1 ]
Grice, S [1 ]
Hammill, SC [1 ]
Stanton, MS [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Div Cardiovasc Dis, Rochester, MN 55905 USA
关键词
D O I
10.1016/S0735-1097(97)00529-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to determine the risk of epicardial lead failure during long-term follow-up and its mode of presentation, Background. Despite the high prevalence of epicardial lead-based implantable cardioverter-defibrillators, their long-term performance is unknown, and appropriate follow-up has not been established, Methods. The study group comprised all patients in whom an epicardial lead system was implanted at the Mayo Clinic between October 31, 1984 and November 3, 1994, The number of lead fractures and leads with fluid within the insulation and the made of presentation were determined retrospectively by review of patient visits, radiographs of lead systems and data derived from formal lead testing. Results. At 4 years, the survival rate free of lead malfunction, using formal lead testing, for 160 Medtronic epicardial patches (models 6897 and 6921) was 72% compared with 92.5% for the 179 Cardiac Pacemaker, Inc. (CPI) patches (models 0040 and 0041) (p = = 0.01). In addition, five Medtronic patches in three patients had fluid within the lead insulation but no obvious fracture, No CPI patches had fluid identified within the leads. Of 330 Medtronic epicardial pace/sense leads (model 6917), the 4-year survival rate Free of lead malfunction as assessed by lead testing was 94%. In all, 18 presentations of lead malfunction were found in 17 patients (2 patients had more than one lead fracture at different times). In 11 (58%) of these presentations, the patients were asymptomatic despite the presence of obvious lead fracture. Conclusions. Epicardial lead malfunction is common on long-term follow-up, and some leads have a failure rate of 28% at 4 years. Many patients with fractured leads remain asymptomatic, despite involvement of multiple leads in some casts, Therefore, consideration should be given to regular periodic lead testing in addition to routine X-ray examination, as as symptomatic lead malfunction can present with normal chest X-ray findings. (C) 1998 by the American College of Cardiology.
引用
收藏
页码:616 / 622
页数:7
相关论文
共 50 条
  • [1] High failure rate for an epicardial cardioverter-defibrillator lead: implications for long term follow-up of patients with an implantable cardioverter-defibrillator (vol 31, pg 616, 1998)
    Brady, PA
    Friedman, PA
    Trusty, JM
    Grice, S
    Hammill, SC
    Stanton, MS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (02) : 555 - 555
  • [2] HIGH FAILURE RATE FOR A CHRONIC EPICARDIAL IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR LEAD
    BRADY, P
    FRIEDMAN, PA
    TRUSTY, JM
    GRICE, SE
    HAMMILL, SC
    STANTON, MS
    [J]. CIRCULATION, 1995, 92 (08) : 716 - 716
  • [3] Individualization of follow-up in implantable cardioverter-defibrillator patients with the help of automatic remote implantable cardioverter-defibrillator monitoring
    Neuser, H
    Schumacher, B
    Kottkamp, H
    Schmidinger, H
    Schuchert, A
    Brugada, P
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 : 166 - 166
  • [4] Long-term follow-up of paediatric patients with a subcutaneous implantable cardioverter-defibrillator
    Van der Stuijt, W.
    De Wilde, K. C.
    Baalman, S. W. E.
    Quast, A. B. E.
    Blom, N. A.
    Wilde, A. A. M.
    Knops, R. E.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 3209 - 3209
  • [5] Implantable cardioverter-defibrillator in Brugada syndrome: Long-term follow-up
    El-Battrawy, Ibrahim
    Roterberg, Gretje
    Liebe, Volker
    Ansari, Uzair
    Lang, Siegfried
    Zhou, Xiaobo
    Borggrefe, Martin
    Akin, Ibrahim
    [J]. CLINICAL CARDIOLOGY, 2019, 42 (10) : 958 - 965
  • [6] Clinical follow-up of patients with implantable cardioverter-defibrillator
    da Fonseca, Silvia Martelo Souza
    Belo, Luiz Gustavo
    Carvalho, Hecio
    Araujo, Nilson
    Munhoz, Claudio
    Siqueira, Leonardo
    Maciel, Washington
    Andrea, Eduardo
    Atie, Jacob
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2007, 88 (01) : 8 - 16
  • [7] Long-term follow-up of children and young adults treated with implantable cardioverter-defibrillator: the authors' own experience with optimal implantable cardioverter-defibrillator programming
    Lewandowski, Michal
    Sterlinski, Maciej
    Maciag, Aleksander
    Syska, Pawel
    Kowalik, Ilona
    Szwed, Hanna
    Chojnowska, Lidia
    Przybylski, Andrzej
    [J]. EUROPACE, 2010, 12 (09): : 1245 - 1250
  • [8] Long-Term Follow-Up of Patients with Chronic Chagas Disease and Implantable Cardioverter-Defibrillator
    Moreira Pereira, Francisca Tatiana
    Rocha, Eduardo Arrais
    Martins Monteiro, Marcelo De Paula
    Rocha Neto, Almino Cavalcante
    Daher, Elisabeth De Francesco
    Martins Rodrigues Sobrinho, Carlos Roberto
    Pires Neto, Roberto Da Justa
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (06): : 751 - 756
  • [9] Long-term follow-up of lead-related complications in 687 patients with implantable cardioverter-defibrillator
    Lighezan, D
    Hilbel, T
    Senges, J
    Becker, R
    Bauer, A
    Freigang, K
    Melkuomov, M
    Weretka, S
    Ruf-Richter, J
    Schoels, W
    [J]. EUROPEAN HEART JOURNAL, 2000, 21 : 121 - 121
  • [10] The implantable cardioverter-defibrillator
    Raj, SR
    Sheldon, RS
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 2001, 44 (03) : 169 - 194