Clinical follow-up of patients with implantable cardioverter-defibrillator

被引:19
|
作者
da Fonseca, Silvia Martelo Souza [1 ]
Belo, Luiz Gustavo [1 ]
Carvalho, Hecio [1 ]
Araujo, Nilson [1 ]
Munhoz, Claudio [1 ]
Siqueira, Leonardo [1 ]
Maciel, Washington [1 ]
Andrea, Eduardo [1 ]
Atie, Jacob [1 ]
机构
[1] Hosp Univ Clementino Fraga Filho, Clin Sao Vicente, Rio De Janeiro, Brazil
关键词
sudden death; implantable cardioverter-defibrillator; appropriate and inappropriate discharges; ischemic and nonischemic heart disease;
D O I
10.1590/S0066-782X2007000100002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To report appropriate (AT) and inappropriate (IT) ICD therapies in patients with ischemic and nonischemic heart disease, as well as early and late procedure-related complications. Methods: One hundred and fifty-five patients 0 19 mate and 36 female), mean age 4 7 years (21-88), who underwent ICD implantation between 1994 and March 2003 were analyzed. Patients were divided into the following groups: Group I - Pbst-AMI patients (n = 80); Group II - Patients with nonischemic heart disease and LV ejection fraction < 40% (n 45), Chagas disease (n = 18), idiopathic dilated cardiomyopathy (n = 12), hypertensive disease (n = 8), hypertrophic cardiomyopathy (n 4) and valvular heart disease (n = 3); Group III - Patients with arrhythmogenic right ventricular dysplasia (n = 13); and Group IV - Patients with channelopathies: Brugada Syndrome (n = 8) and idiopathic ventricular arrhythmias (n = 9). All patients underwent electrophysiological study (EPS) with induction of sustained ventricular arrhythmia ICD implantation. Results: During the 26-month mean follow up, a high rate of appropriate ICD therapies (antitachycardia pacing and/or shock) was observed (46%) in the four groups, with no statistically significant difference. The four groups did not differ in either overall (8.4%) or arrhythmic mortality (1.3%). There was no correlation between appropriate ICD therapies and initial clinical presentation or inducible ventricular arrhythmia at EPS, and a 4% incidence of early and late procedure-related complications was found. Conclusion: The high incidence of appropriate ICD therapy and low rate of sudden death in the patients studied suggest that ICD is a valuable strategy in the management of ischemic and nonischemic patients previously selected by means of EPS.
引用
收藏
页码:8 / 16
页数:9
相关论文
共 50 条
  • [1] Individualization of follow-up in implantable cardioverter-defibrillator patients with the help of automatic remote implantable cardioverter-defibrillator monitoring
    Neuser, H
    Schumacher, B
    Kottkamp, H
    Schmidinger, H
    Schuchert, A
    Brugada, P
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 : 166 - 166
  • [2] FOLLOW-UP OF 51 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    TROUP, PJ
    DUQUETTE, SE
    CHAPMAN, PD
    [J]. CLINICAL RESEARCH, 1986, 34 (04): : A903 - A903
  • [3] Clinical course of implantable cardioverter-defibrillator patients; prolonged follow-up in routine clinical practice
    Van der Heijden, A. C.
    Buiten, M. S.
    Thijssen, J.
    Van Rees, J. B.
    Erven, L.
    Schalij, M. J.
    Borleffs, C. J. W.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 49 - 49
  • [4] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - CLINICAL-EXPERIENCE, COMPLICATIONS, AND FOLLOW-UP IN 25 PATIENTS
    BORBOLA, J
    DENES, P
    EZRI, MD
    HAUSER, RG
    SERRY, C
    GOLDIN, MD
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1988, 148 (01) : 70 - 76
  • [5] High failure rate for an epicardial implantable cardioverter-defibrillator lead: Implications for long-term follow-up of patients with an implantable cardioverter-defibrillator
    Brady, PA
    Friedman, PA
    Trusty, JM
    Grice, S
    Hammill, SC
    Stanton, MS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) : 616 - 622
  • [6] Long-term follow-up of paediatric patients with a subcutaneous implantable cardioverter-defibrillator
    Van der Stuijt, W.
    De Wilde, K. C.
    Baalman, S. W. E.
    Quast, A. B. E.
    Blom, N. A.
    Wilde, A. A. M.
    Knops, R. E.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 3209 - 3209
  • [7] The Implantable Cardioverter-Defibrillator Minimalist An Approach to Patient Follow-Up and Management of Implantable Defibrillators
    Sweeney, Michael O.
    [J]. CIRCULATION, 2012, 126 (03) : 369 - 377
  • [8] Subcutaneous implantable cardioverter-defibrillator electrode fracture: Follow-up, troubleshooting, and evaluation
    Kella, Danesh K.
    Stambler, Bruce S.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (05) : 1452 - 1457
  • [9] Implantable cardioverter-defibrillator in Brugada syndrome: Long-term follow-up
    El-Battrawy, Ibrahim
    Roterberg, Gretje
    Liebe, Volker
    Ansari, Uzair
    Lang, Siegfried
    Zhou, Xiaobo
    Borggrefe, Martin
    Akin, Ibrahim
    [J]. CLINICAL CARDIOLOGY, 2019, 42 (10) : 958 - 965
  • [10] Long-Term Follow-Up of Patients with Chronic Chagas Disease and Implantable Cardioverter-Defibrillator
    Moreira Pereira, Francisca Tatiana
    Rocha, Eduardo Arrais
    Martins Monteiro, Marcelo De Paula
    Rocha Neto, Almino Cavalcante
    Daher, Elisabeth De Francesco
    Martins Rodrigues Sobrinho, Carlos Roberto
    Pires Neto, Roberto Da Justa
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (06): : 751 - 756