Clinical follow-up of patients with implantable cardioverter-defibrillator

被引:19
|
作者
da Fonseca, Silvia Martelo Souza [1 ]
Belo, Luiz Gustavo [1 ]
Carvalho, Hecio [1 ]
Araujo, Nilson [1 ]
Munhoz, Claudio [1 ]
Siqueira, Leonardo [1 ]
Maciel, Washington [1 ]
Andrea, Eduardo [1 ]
Atie, Jacob [1 ]
机构
[1] Hosp Univ Clementino Fraga Filho, Clin Sao Vicente, Rio De Janeiro, Brazil
关键词
sudden death; implantable cardioverter-defibrillator; appropriate and inappropriate discharges; ischemic and nonischemic heart disease;
D O I
10.1590/S0066-782X2007000100002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To report appropriate (AT) and inappropriate (IT) ICD therapies in patients with ischemic and nonischemic heart disease, as well as early and late procedure-related complications. Methods: One hundred and fifty-five patients 0 19 mate and 36 female), mean age 4 7 years (21-88), who underwent ICD implantation between 1994 and March 2003 were analyzed. Patients were divided into the following groups: Group I - Pbst-AMI patients (n = 80); Group II - Patients with nonischemic heart disease and LV ejection fraction < 40% (n 45), Chagas disease (n = 18), idiopathic dilated cardiomyopathy (n = 12), hypertensive disease (n = 8), hypertrophic cardiomyopathy (n 4) and valvular heart disease (n = 3); Group III - Patients with arrhythmogenic right ventricular dysplasia (n = 13); and Group IV - Patients with channelopathies: Brugada Syndrome (n = 8) and idiopathic ventricular arrhythmias (n = 9). All patients underwent electrophysiological study (EPS) with induction of sustained ventricular arrhythmia ICD implantation. Results: During the 26-month mean follow up, a high rate of appropriate ICD therapies (antitachycardia pacing and/or shock) was observed (46%) in the four groups, with no statistically significant difference. The four groups did not differ in either overall (8.4%) or arrhythmic mortality (1.3%). There was no correlation between appropriate ICD therapies and initial clinical presentation or inducible ventricular arrhythmia at EPS, and a 4% incidence of early and late procedure-related complications was found. Conclusion: The high incidence of appropriate ICD therapy and low rate of sudden death in the patients studied suggest that ICD is a valuable strategy in the management of ischemic and nonischemic patients previously selected by means of EPS.
引用
收藏
页码:8 / 16
页数:9
相关论文
共 50 条
  • [11] Over 10 years with an implantable cardioverter-defibrillator - a long term follow-up of 60 patients
    Sterlinski, Maciej
    Przybylski, Andrzej
    Gepner, Katarzyna
    Syska, Pawel
    Maciag, Aleksander
    Lewandowski, Michal
    Kowalik, Ilona
    Pytkowski, Manusz
    Sitkowska-Rysiak, Ewa
    Lichomski, Jerzy
    Szwed, Hanna
    Sadowski, Zygmunt
    [J]. KARDIOLOGIA POLSKA, 2010, 68 (09) : 1023 - 1031
  • [12] Implantable cardioverter/defibrillator (ICD) follow-up
    Gwechenberger, M.
    [J]. JOURNAL FUR KARDIOLOGIE, 2023, 30 (11-12): : 276 - 280
  • [13] Long-term follow-up of children and young adults treated with implantable cardioverter-defibrillator: the authors' own experience with optimal implantable cardioverter-defibrillator programming
    Lewandowski, Michal
    Sterlinski, Maciej
    Maciag, Aleksander
    Syska, Pawel
    Kowalik, Ilona
    Szwed, Hanna
    Chojnowska, Lidia
    Przybylski, Andrzej
    [J]. EUROPACE, 2010, 12 (09): : 1245 - 1250
  • [14] Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory
    Guedon-Moreau, Laurence
    Chevalier, Philippe
    Marquie, Christelle
    Kouakam, Claude
    Klug, Didier
    Lacroix, Dominique
    Brigadeau, Francois
    Kacet, Salem
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (18) : 2246 - 2252
  • [15] Outcome of advisory implantable cardioverter-defibrillator replacement: One-year follow-up
    Gould, Paul A.
    Gula, Lorne J.
    Champagne, Jean
    Healyey, Jeffrey S.
    Cameron, Doug
    Simpson, Christophers
    Thibault, Bernard
    Pinter, Arnold
    Tung, Stanley
    Sterns, Laurence
    Birnie, David
    Exner, Derek
    Parkash, Ratika
    Skanes, Allan C.
    Yee, Raymond
    Klein, George J.
    Krahn, Andrew D.
    [J]. HEART RHYTHM, 2008, 5 (12) : 1675 - 1681
  • [16] Stability and cause of anxiety in patients with an implantable cardioverter-defibrillator:: A longitudinal two-year follow-up
    Croessmann, Alexander
    Pauli, Paul
    Dengler, Wilhelm
    Kuehlkamp, Volker
    Wiedemann, Georg
    [J]. HEART & LUNG, 2007, 36 (02): : 87 - 95
  • [17] COMBINED AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR AND PACEMAKER SYSTEMS - IMPLANTATION TECHNIQUES AND FOLLOW-UP
    EPSTEIN, AE
    KAY, GN
    PLUMB, VJ
    SHEPARD, RB
    KIRKLIN, JK
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (01) : 121 - 131
  • [18] Clinical Outcomes of Implantable Cardioverter-Defibrillator in Pediatric Patients
    Song, Mi Kyoung
    Uhm, Jae-Sun
    Baek, Jae Suk
    Yoon, Ja Kyoung
    Na, Jae Yoon
    Yu, Hee Tae
    Yang, Ji-Hyuk
    Oh, Seil
    Park, Sang Weon
    Song, Jinyoung
    Huh, June
    Bae, Eun-Jung
    [J]. CIRCULATION JOURNAL, 2021, 85 (08) : 1356 - +
  • [19] COMPLICATIONS OF IMPLANTABLE CARDIOVERTER DEFIBRILLATOR THERAPY - FOLLOW-UP OF 241 PATIENTS
    GRIMM, W
    FLORES, BF
    MARCHLINSKI, FE
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (01): : 218 - 222
  • [20] Follow-up of the patient with automatic implantable cardioverter defibrillator
    Cruz Cardentey, Marleny
    Prieto Guerra, Maidelis
    Gutierrez Lopez, Alain
    Mengana Betancourt, Ana
    Ramos Cordero, Michel Y.
    Tannis Wilson, Eko
    Tamargo Barbeito, Teddy O.
    [J]. CORSALUD, 2020, 12 (03): : 283 - 291