Over 10 years with an implantable cardioverter-defibrillator - a long term follow-up of 60 patients

被引:0
|
作者
Sterlinski, Maciej [1 ]
Przybylski, Andrzej [1 ]
Gepner, Katarzyna [1 ]
Syska, Pawel [1 ]
Maciag, Aleksander [1 ]
Lewandowski, Michal [1 ]
Kowalik, Ilona [1 ]
Pytkowski, Manusz [1 ]
Sitkowska-Rysiak, Ewa [1 ]
Lichomski, Jerzy [1 ]
Szwed, Hanna [1 ]
Sadowski, Zygmunt [1 ]
机构
[1] Inst Cardiol, PL-02637 Warsaw, Poland
关键词
implantable cardioverter defibrillator; long term observation; survival; appropriate and inappropriate interventions; complications; SUDDEN CARDIAC DEATH; MYOCARDIAL-INFARCTION; TEMPORAL TRENDS; UNITED-STATES; HIGH-RISK; THERAPY; PREVENTION; EXPERIENCE; RECIPIENTS; SURVIVAL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transvenous implantable cardioverter defibrillators (ICD) have been implanted in Poland since 1995 As the method spreads it is important to consider its long-term benefits and disadvantages Aim To assess survival efficacy and complication rate in ICD patients, who received the device more than ten years earlier Methods Retrospective analysis of 60 ICD patients implanted between 1995-1999 Results There were 42 (70%) males, mean age 50 6 +/- 16 4 years In 59 patients ICD was implanted for sudden cardiac death (SCD) secondary prevention Thirty eight patients (34 M, 63 3%) had coronary artery disease (CAD) The CAD was diagnosed in 89 5% of males and 10 5% of females (p < 0 0001) Mean follow-up time was 75 4 +/- 34 7 months During this time 22 patients died (37%, 19 M, 3 F) Three deaths were SCD Mean one-year mortality was 6 7% Deaths were more frequent among males 45 2% vs 16 7%, p < 0 005 In CAD mortality was higher than in non-CAD patients (50% vs 13 6% p < 0 005) Appropriate ICD discharges in the ventricular fibrillation (VF) zone occurred in 35 (58%) patients and in ventricular tachycardia (VT) zone - in 26 (43%) patients Mean intervention rate per year was 3 7 for VF and 0 6 for VT Complications occurred in 27 (45%) patients and 5 (8%) of them had no ICD intervention during follow-up In 5 patients more than one complication was diagnosed There were inappropriate discharges in 15 (25%) patients, 11 (18%) had electrical storm and ICD related infections were noted in 3 (5%) patients During the penoperative period, lead revisions were done in 4 patients, in 3 with discharges induced by T-wave oversensing and in one with lead dislocation Four cases of lead failure occurred during follow up, requiring new lead implantation In 4 patients, electrical storm (3 patients) and supraventricular tachycardia with ICD discharges (1 patient) were treated with radiofrequency ablation Only 10 (17%) patients did not demonstrate any ICD interventions or ICD related complications Conclusions 1 ICD interventions caused by malignant ventricular arrhythmias occurred in 75% patients with the device implanted more than 10 years earlier 2 Almost a half of the analysed population suffered from complications and side effects related to implanted ICD and they were present in 8% of subjects without ICD intervention Neither ICD interventions nor device related adverse events were recorded in 17% of patients
引用
收藏
页码:1023 / 1031
页数:9
相关论文
共 50 条
  • [1] Long-term follow-up of paediatric patients with a subcutaneous implantable cardioverter-defibrillator
    Van der Stuijt, W.
    De Wilde, K. C.
    Baalman, S. W. E.
    Quast, A. B. E.
    Blom, N. A.
    Wilde, A. A. M.
    Knops, R. E.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 3209 - 3209
  • [2] High failure rate for an epicardial implantable cardioverter-defibrillator lead: Implications for long-term follow-up of patients with an implantable cardioverter-defibrillator
    Brady, PA
    Friedman, PA
    Trusty, JM
    Grice, S
    Hammill, SC
    Stanton, MS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) : 616 - 622
  • [3] Clinical follow-up of patients with implantable cardioverter-defibrillator
    da Fonseca, Silvia Martelo Souza
    Belo, Luiz Gustavo
    Carvalho, Hecio
    Araujo, Nilson
    Munhoz, Claudio
    Siqueira, Leonardo
    Maciel, Washington
    Andrea, Eduardo
    Atie, Jacob
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2007, 88 (01) : 8 - 16
  • [4] Implantable cardioverter-defibrillator in Brugada syndrome: Long-term follow-up
    El-Battrawy, Ibrahim
    Roterberg, Gretje
    Liebe, Volker
    Ansari, Uzair
    Lang, Siegfried
    Zhou, Xiaobo
    Borggrefe, Martin
    Akin, Ibrahim
    [J]. CLINICAL CARDIOLOGY, 2019, 42 (10) : 958 - 965
  • [5] Long-Term Follow-Up of Patients with Chronic Chagas Disease and Implantable Cardioverter-Defibrillator
    Moreira Pereira, Francisca Tatiana
    Rocha, Eduardo Arrais
    Martins Monteiro, Marcelo De Paula
    Rocha Neto, Almino Cavalcante
    Daher, Elisabeth De Francesco
    Martins Rodrigues Sobrinho, Carlos Roberto
    Pires Neto, Roberto Da Justa
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (06): : 751 - 756
  • [6] Individualization of follow-up in implantable cardioverter-defibrillator patients with the help of automatic remote implantable cardioverter-defibrillator monitoring
    Neuser, H
    Schumacher, B
    Kottkamp, H
    Schmidinger, H
    Schuchert, A
    Brugada, P
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 : 166 - 166
  • [7] FOLLOW-UP OF 51 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    TROUP, PJ
    DUQUETTE, SE
    CHAPMAN, PD
    [J]. CLINICAL RESEARCH, 1986, 34 (04): : A903 - A903
  • [8] Long-term follow-up of children and young adults treated with implantable cardioverter-defibrillator: the authors' own experience with optimal implantable cardioverter-defibrillator programming
    Lewandowski, Michal
    Sterlinski, Maciej
    Maciag, Aleksander
    Syska, Pawel
    Kowalik, Ilona
    Szwed, Hanna
    Chojnowska, Lidia
    Przybylski, Andrzej
    [J]. EUROPACE, 2010, 12 (09): : 1245 - 1250
  • [9] Implantable cardioverter-defibrillator therapy in patients with congenital long-QT syndrome:: A long-term follow-up
    Mönnig, G
    Köbe, J
    Löher, A
    Eckardt, L
    Wedekind, H
    Scheld, HH
    Haverkamp, W
    Milberg, P
    Breithardt, G
    Schulze-Bahr, E
    Böcker, D
    [J]. HEART RHYTHM, 2005, 2 (05) : 497 - 504
  • [10] Long-term follow-up of lead-related complications in 687 patients with implantable cardioverter-defibrillator
    Lighezan, D
    Hilbel, T
    Senges, J
    Becker, R
    Bauer, A
    Freigang, K
    Melkuomov, M
    Weretka, S
    Ruf-Richter, J
    Schoels, W
    [J]. EUROPEAN HEART JOURNAL, 2000, 21 : 121 - 121