COMPLICATIONS OF IMPLANTABLE CARDIOVERTER DEFIBRILLATOR THERAPY - FOLLOW-UP OF 241 PATIENTS

被引:95
|
作者
GRIMM, W [1 ]
FLORES, BF [1 ]
MARCHLINSKI, FE [1 ]
机构
[1] HOSP UNIV PENN,DEPT MED,DIV CARDIOL,CLIN ELECTROPHYSIOL LAB,F9131 FOUNDERS PAVIL,3400 SPRUCE ST,PHILADELPHIA,PA 19104
来源
关键词
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; COMPLICATIONS;
D O I
10.1111/j.1540-8159.1993.tb01565.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In order to determine the incidence of complications of implantable cardioverter defibrillator (ICD) therapy, 241 patients with a total of 353 ICD implantations were followed for 24 +/- 20 months. Complications were defined as any untoward effects experienced by the patient related to the ICD implantation and function or death within 4 weeks of implant or before hospital discharge. During follow-up, 129 of 241 patients (53%) had a total of 166 complications. An operative procedure was required to correct the complication in 50 of the 241 patients (21%). No patient died intraoperatively, but eight patients died within 4 weeks postoperatively or before hospital discharge. ICD infection required removal of the device in 13 patients (5%). Twenty-six patients (i 1%) had postoperative respiratory complications. Postoperative bleeding and/or thrombosis occurred in 11 patients (4%). Endocardial lead migration was observed in nine patients (4%) and lead adapter or insulation break occurred in nine patients (4%). Fifty-four patients (22%) experienced ECG-documented discharges for non-VT rhythm. In conclusion, although perioperative mortality in ICD patients is low, the majority of patients have complications during follow-up. Recognition of these complications may allow for advances in ICD technology and management strategies to avoid their occurrence.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 50 条
  • [1] Implantable cardioverter/defibrillator (ICD) follow-up
    Gwechenberger, M.
    [J]. JOURNAL FUR KARDIOLOGIE, 2023, 30 (11-12): : 276 - 280
  • [2] Clinical follow-up of patients with implantable cardioverter-defibrillator
    da Fonseca, Silvia Martelo Souza
    Belo, Luiz Gustavo
    Carvalho, Hecio
    Araujo, Nilson
    Munhoz, Claudio
    Siqueira, Leonardo
    Maciel, Washington
    Andrea, Eduardo
    Atie, Jacob
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2007, 88 (01) : 8 - 16
  • [3] Long-term follow-up of implantable cardioverter defibrillator patients with regard to appropriate therapy, complications, and mortality
    Mattsson, Gustav
    Magnusson, Peter
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (02): : 245 - 253
  • [4] Follow-up of the patient with automatic implantable cardioverter defibrillator
    Cruz Cardentey, Marleny
    Prieto Guerra, Maidelis
    Gutierrez Lopez, Alain
    Mengana Betancourt, Ana
    Ramos Cordero, Michel Y.
    Tannis Wilson, Eko
    Tamargo Barbeito, Teddy O.
    [J]. CORSALUD, 2020, 12 (03): : 283 - 291
  • [5] FOLLOW-UP OF 51 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    TROUP, PJ
    DUQUETTE, SE
    CHAPMAN, PD
    [J]. CLINICAL RESEARCH, 1986, 34 (04): : A903 - A903
  • [6] Longitudinal Follow-Up of Implantable Cardioverter Defibrillator Leads
    Liu, Jeffrey
    Brumberg, Genevieve
    Rattan, Rohit
    Patel, Divyang
    Adelstein, Evan
    Jain, Sandeep
    Saba, Samir
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2014, 113 (01): : 103 - 106
  • [7] Individualization of follow-up in implantable cardioverter-defibrillator patients with the help of automatic remote implantable cardioverter-defibrillator monitoring
    Neuser, H
    Schumacher, B
    Kottkamp, H
    Schmidinger, H
    Schuchert, A
    Brugada, P
    [J]. EUROPEAN HEART JOURNAL, 2004, 25 : 166 - 166
  • [8] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - CLINICAL-EXPERIENCE, COMPLICATIONS, AND FOLLOW-UP IN 25 PATIENTS
    BORBOLA, J
    DENES, P
    EZRI, MD
    HAUSER, RG
    SERRY, C
    GOLDIN, MD
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1988, 148 (01) : 70 - 76
  • [9] Implantable cardioverter defibrillator clinic casualties: Inadvertent reprogramming during routine implantable cardioverter defibrillator follow-up
    Ozahowski, TP
    Greenberg, ML
    Mock, P
    Holzberger, PT
    Gerling, B
    Zalinger, C
    Perry, C
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (10): : 1524 - 1525
  • [10] Follow-up of patients with implanted implantable cardioverter defibrillator without defibrillation test
    Femenia, Francisco J.
    Penafort, Fernando
    Arce, Mauricio
    Arrieta, Martin
    Gutierrez, Daniel
    [J]. REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2009, 38 (03): : 132 - 137