INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY CHARACTERISTICS AT SELECTED LIBRARIES IN PAHANG

被引:0
|
作者
Hizrri, A. [1 ]
Khadijah, H. [1 ]
Hadry, Noor Faizul N. [1 ]
Norhidayah, A. [2 ]
Shukri, Mohd M. A. [1 ]
机构
[1] Int Islam Univ Malaysia, Kulliyyah Sci, Dept Biotechnol, Kuantan Campus, Pahang, Malaysia
[2] Univ Malaysia Pahang, Fac Technol, Dept Occupat Safety & Hlth, Pahang, Malaysia
来源
JURNAL TEKNOLOGI | 2015年 / 77卷 / 24期
关键词
Indoor air quality (IAQ); library; airborne pollutants; particulate matter (PM); CFU microbes; Aerococcus viridans;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Library contains huge collection of books that can undergo biodeterioration process after period of time. Due to this biological reaction, the existence of airborne particulate matters and microbes in the air of the library can be disturbed and elevated, thus can cause health implications to occupants. Therefore, it is an urge to assess and understand the correlation between physical indoor air quality (IAQ) characteristics, airborne pollutants and microbial contaminants in different library settings and locations. This study was carried out at three different libraries, which are Library A (Gambang as suburban area), Library B (Kuantan as urban area) and Library C (Pekan as rural area). The physical IAQ characteristics and particulate matter (PM) monitoring were assessed by using IAQ Meter and DustMate respectively. Surface Air System IAQ (SAS IAQ) was used to collect the airborne microbes. The microbial contamination was further assessed and identified in the laboratory by using API 20E and API 20 Strep while SPSS was used to analyze the relationship of physical IAQ characteristics, airborne pollutants and airborne microbes contaminants. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practise on Indoor Air Quality, 2010 (ICOP, 2010) regulated by the Department of Occupational Safety and Health (DOSH). Respirable PM in Library A and CFU counts in Library A and C exceeded the standard limit with the value of 0.30 mg/m(3), 2744 CFU/m(3) and 1833 CFU/m(3) respectively. Significant differences (p < 0.05) between the selected libraries were observed among relative humidity (p=0.001), inhalable PM (p=0.001), thoracic PM (p=0.001), respirable PM (p= 0.01), CO2 reading (p=0.001) and CFU counts (p= 0.01). This study demonstrated Library C has poor air quality as the reading for CO2 and CFU counts are very high compared with the other two libraries. The bacterial identification findings indicated that Gram positive bacteria were abundant compared to Gram negative bacteria. Aerococcus viridans is the most dominant type of bacteria isolated in all the libraries.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [1] INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY (IAQ) CHARACTERISTICS AT DIFFERENT LABORATORY CONDITIONS
    Hazrin, A. H.
    Syazana, Anis A. A.
    Hadry, Noor Faizul N.
    Norhidayah, A.
    Shukri, Mohd M. A.
    [J]. JURNAL TEKNOLOGI, 2015, 77 (24): : 39 - 44
  • [2] Indoor air quality (IAQ) characteristics and its microbial community identifications at two selected schools in Pahang, Malaysia: a preliminary study
    Hizrri, A.
    Nabilah, Zati M. G.
    Amni, Nurul Z.
    Shahida, N.
    Maryam, Z.
    Hazrin, A. H.
    Faez, Mohd S.
    Shukri, Mohd M. A.
    [J]. ASIAN JOURNAL OF AGRICULTURE AND BIOLOGY, 2018, 6 : 88 - 96
  • [3] Indoor air quality in X's University Libraries (Physical, chemical and microbial aspects)
    Fitria, Laila
    Wulandari, Ririn Arminsih
    Hermawati, Ema
    Susanna, Dewi
    [J]. MAKARA JOURNAL OF HEALTH RESEARCH, 2008, 12 (02): : 76 - 82
  • [4] A Review of Selected Types of Indoor Air Purifiers in Terms of Microbial Air Contamination Reduction
    Szczotko, Maciej
    Orych, Izabela
    Maka, Lukasz
    Solecka, Jolanta
    [J]. ATMOSPHERE, 2022, 13 (05)
  • [5] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Kadaifciler, Duygu Goksay
    Cotuk, Aysin
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (06) : 3431 - 3444
  • [6] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Duygu Göksay Kadaifciler
    Aysin Cotuk
    [J]. Environmental Monitoring and Assessment, 2014, 186 : 3431 - 3444
  • [7] Microbial air contamination in indoor environment of a university library
    Kalwasinska, Agnieszka
    Burkowska, Aleksandra
    Wilk, Iwona
    [J]. ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2012, 19 (01) : 25 - 29
  • [8] LABORATORY FACILITY DESIGN AND MICROBIAL INDOOR AIR QUALITY IN SELECTED HOSPITAL LABORATORIES
    Luksamijarulkul, Pipat
    Kiennukul, Nuchanard
    Vatthanasomboon, Pisit
    [J]. SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2014, 45 (03) : 746 - 755
  • [9] Indoor air quality in the university libraries of Modena (Italy)
    Fantuzzi, G
    Aggazzotti, G
    Righi, E
    Cavazzuti, L
    Predieri, G
    Franceschelli, A
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1996, 193 (01) : 49 - 56
  • [10] Indoor air quality of libraries in Sao Paulo, Brazil
    Ito, Lissandra Xavier
    Aguiar, Monica Lopes
    [J]. INDOOR AND BUILT ENVIRONMENT, 2007, 16 (02) : 190 - 193