INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY (IAQ) CHARACTERISTICS AT DIFFERENT LABORATORY CONDITIONS

被引:0
|
作者
Hazrin, A. H. [1 ]
Syazana, Anis A. A. [1 ]
Hadry, Noor Faizul N. [1 ]
Norhidayah, A. [2 ]
Shukri, Mohd M. A. [1 ]
机构
[1] Int Islam Univ Malaysia, Dept Biotechnol, Kulliyyah Sci, Kuantan Campus, Pahang, Malaysia
[2] Univ Malaysia Pahang, Fac Technol, Dept Occupat Safety & Hlth, Gambang, Pahang, Malaysia
来源
JURNAL TEKNOLOGI | 2015年 / 77卷 / 24期
关键词
Indoor air quality (IAQ); laboratory; airborne pollutants; particulate matter (PM); microbes; CFU;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Laboratory usually refers to a room or building equipped with chemicals and biological agents for scientific experimentation and research. Due to its own indoor hazards and its cause of health implications, it is an urge to assess and to understand the physical indoor air quality (IAQ) characteristics in the laboratory and the variables affecting the degree of exposure to occupants. The main objectives of this study was aimed to assess and to compare the physical IAQ characteristics and airborne pollutants including particulate matters (PM) and gaseous pollutants between laboratories, to identify microbial contaminants via bacterial counts as well as scientific bacterial-kits species identification and to correlate the relationship of physical IAQ characteristics, airborne pollutants and microbial contaminants between different laboratory settings within the same building which are Natural Product (NP) laboratory, Plant Tissue Culture (PTC) laboratory, and Microbiology laboratory. The physical IAQ characteristics and airborne PM was measured using VelociCalc multi-function ventilation meter 9565 and DustMate environmental dust detector respectively. Surface Air System Indoor Air Quality (SAS IAQ) was used to capture the microbial contaminants and after that bacterial counting and identification were done. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practice on Indoor Air Quality (ICOP) (2010) regulated by the Department of Occupational Safety and Health (DOSH). The temperature of PTC laboratory, velocity of NP laboratory and Microbiology laboratory, the respirable particulate matter (PM) of all three laboratories and Colony Forming Unit (CFU) count of PTC and NP laboratory exceeded the standard limit regulated by DOSH. This study demonstrated that Gemella morbillorum is the common bacterial species available in the environment with poor IAQ and there is a significant relationship between physical characteristics, airborne pollutants and microbial contaminants between the different types of laboratory settings. In conclusion, priority should be given to NP laboratory as it is exposed to poor IAQ conditions and immediate action should be taken to eliminate the problems.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [1] INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY CHARACTERISTICS AT SELECTED LIBRARIES IN PAHANG
    Hizrri, A.
    Khadijah, H.
    Hadry, Noor Faizul N.
    Norhidayah, A.
    Shukri, Mohd M. A.
    JURNAL TEKNOLOGI, 2015, 77 (24): : 51 - 56
  • [2] INDOOR AIR-QUALITY (IAQ)
    COKER, WR
    ASHRAE JOURNAL, 1989, 31 (07) : 5 - 5
  • [3] Indoor Air Quality (IAQ) and Energy Efficiency
    Ram, D. Nirmal
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 1, 2019, 125 : 231 - 237
  • [4] Open forum on indoor air quality (IAQ)
    Asia Engineer, 2000, 28 (02):
  • [5] Data on Indoor Air Quality (IAQ) in kindergartens with different surrounding activities
    Abdullah, Samsuri
    Abd Hamid, Farah Fasihah
    Ismail, Marzuki
    Ahmed, Ali Najah
    Mansur, Wan Nurdiyana Wan
    DATA IN BRIEF, 2019, 25
  • [6] Indoor air quality (IAQ) characteristics and its microbial community identifications at two selected schools in Pahang, Malaysia: a preliminary study
    Hizrri, A.
    Nabilah, Zati M. G.
    Amni, Nurul Z.
    Shahida, N.
    Maryam, Z.
    Hazrin, A. H.
    Faez, Mohd S.
    Shukri, Mohd M. A.
    ASIAN JOURNAL OF AGRICULTURE AND BIOLOGY, 2018, 6 : 88 - 96
  • [7] Parameters of Indoor Air Quality (IAQ) in Wooden Houses
    Svitak, Martin
    Krontorad, Karel
    Kropacek, Jan
    Hlaskova, Lud'ka
    Solar, Ales
    BIORESOURCES, 2018, 13 (04): : 8222 - 8238
  • [8] Sustainable Indoor Air Quality (IAQ) in Hospital Buildings
    Dikmen, Cigdem Belgin
    Gultekin, Arzuhan Burcu
    SURVIVAL AND SUSTAINABILITY: ENVIRONMENTAL CONCERNS IN THE 21ST CENTURY, 2011, : 557 - 565
  • [9] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Kadaifciler, Duygu Goksay
    Cotuk, Aysin
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (06) : 3431 - 3444
  • [10] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Duygu Göksay Kadaifciler
    Aysin Cotuk
    Environmental Monitoring and Assessment, 2014, 186 : 3431 - 3444