INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY (IAQ) CHARACTERISTICS AT DIFFERENT LABORATORY CONDITIONS

被引:0
|
作者
Hazrin, A. H. [1 ]
Syazana, Anis A. A. [1 ]
Hadry, Noor Faizul N. [1 ]
Norhidayah, A. [2 ]
Shukri, Mohd M. A. [1 ]
机构
[1] Int Islam Univ Malaysia, Dept Biotechnol, Kulliyyah Sci, Kuantan Campus, Pahang, Malaysia
[2] Univ Malaysia Pahang, Fac Technol, Dept Occupat Safety & Hlth, Gambang, Pahang, Malaysia
来源
JURNAL TEKNOLOGI | 2015年 / 77卷 / 24期
关键词
Indoor air quality (IAQ); laboratory; airborne pollutants; particulate matter (PM); microbes; CFU;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Laboratory usually refers to a room or building equipped with chemicals and biological agents for scientific experimentation and research. Due to its own indoor hazards and its cause of health implications, it is an urge to assess and to understand the physical indoor air quality (IAQ) characteristics in the laboratory and the variables affecting the degree of exposure to occupants. The main objectives of this study was aimed to assess and to compare the physical IAQ characteristics and airborne pollutants including particulate matters (PM) and gaseous pollutants between laboratories, to identify microbial contaminants via bacterial counts as well as scientific bacterial-kits species identification and to correlate the relationship of physical IAQ characteristics, airborne pollutants and microbial contaminants between different laboratory settings within the same building which are Natural Product (NP) laboratory, Plant Tissue Culture (PTC) laboratory, and Microbiology laboratory. The physical IAQ characteristics and airborne PM was measured using VelociCalc multi-function ventilation meter 9565 and DustMate environmental dust detector respectively. Surface Air System Indoor Air Quality (SAS IAQ) was used to capture the microbial contaminants and after that bacterial counting and identification were done. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practice on Indoor Air Quality (ICOP) (2010) regulated by the Department of Occupational Safety and Health (DOSH). The temperature of PTC laboratory, velocity of NP laboratory and Microbiology laboratory, the respirable particulate matter (PM) of all three laboratories and Colony Forming Unit (CFU) count of PTC and NP laboratory exceeded the standard limit regulated by DOSH. This study demonstrated that Gemella morbillorum is the common bacterial species available in the environment with poor IAQ and there is a significant relationship between physical characteristics, airborne pollutants and microbial contaminants between the different types of laboratory settings. In conclusion, priority should be given to NP laboratory as it is exposed to poor IAQ conditions and immediate action should be taken to eliminate the problems.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [11] Indoor air quality (IAQ) and water damages in Finnish hospitals
    Reijula, KE
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2006, 117 (02) : S27 - S27
  • [12] Indoor air quality (IAQ), pollutants, their sources and methods of elimination
    Wang, JJ
    Xie, YB
    Yuan, FD
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2542 - 2546
  • [13] A Bibliographic Analysis of Indoor Air Quality (IAQ) in Industrial Environments
    Lolli, Francesco
    Coruzzolo, Antonio Maria
    Marinello, Samuele
    Traini, Asia
    Gamberini, Rita
    SUSTAINABILITY, 2022, 14 (16)
  • [14] Application of a whole room indoor air quality (IAQ) model
    Li, Feng
    Niu, Jianlei
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 849 - 853
  • [15] Indoor air quality (IAQ) in Hong Kong service apartment
    Mui, K
    Chan, M
    Leung, C
    Lau, Y
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2660 - 2664
  • [16] Assessing physical conditions of indoor space enclosing elements in schools in relation to their indoor environmental quality
    Sadick, Abdul-Manan
    Issa, Mohamed H.
    JOURNAL OF BUILDING ENGINEERING, 2018, 20 : 520 - 530
  • [17] Microbial air contamination in indoor environment of a university library
    Kalwasinska, Agnieszka
    Burkowska, Aleksandra
    Wilk, Iwona
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2012, 19 (01) : 25 - 29
  • [18] Indoor Air Quality Guidelines Connection to IAQ Certification and Labelling Process
    Sprudza, Klinta Luize
    Klavina, Aneka
    Berzina, Buka
    Kauce, Ruta
    Martinsone, Zanna
    ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, 2023, 27 (01) : 28 - 39
  • [19] The Improvement of Indoor Air Quality (IAQ) by Using Natural and Mechanical Method
    Suriaman, Irwan
    Mardiyati
    Hendrarsakti, Jooned
    Pasek, Ari Darmawan
    INTERNATIONAL CONFERENCE ON THERMAL SCIENCE AND TECHNOLOGY (ICTST) 2017, 2018, 1984
  • [20] Indoor air quality (IAQ) investigation in primary schools at Hamirpur (India)
    Shree, Venu
    Marwaha, Bhanu M.
    Awasthi, Pamita
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2019, 96 (11) : 1455 - 1460