INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY (IAQ) CHARACTERISTICS AT DIFFERENT LABORATORY CONDITIONS

被引:0
|
作者
Hazrin, A. H. [1 ]
Syazana, Anis A. A. [1 ]
Hadry, Noor Faizul N. [1 ]
Norhidayah, A. [2 ]
Shukri, Mohd M. A. [1 ]
机构
[1] Int Islam Univ Malaysia, Dept Biotechnol, Kulliyyah Sci, Kuantan Campus, Pahang, Malaysia
[2] Univ Malaysia Pahang, Fac Technol, Dept Occupat Safety & Hlth, Gambang, Pahang, Malaysia
来源
JURNAL TEKNOLOGI | 2015年 / 77卷 / 24期
关键词
Indoor air quality (IAQ); laboratory; airborne pollutants; particulate matter (PM); microbes; CFU;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Laboratory usually refers to a room or building equipped with chemicals and biological agents for scientific experimentation and research. Due to its own indoor hazards and its cause of health implications, it is an urge to assess and to understand the physical indoor air quality (IAQ) characteristics in the laboratory and the variables affecting the degree of exposure to occupants. The main objectives of this study was aimed to assess and to compare the physical IAQ characteristics and airborne pollutants including particulate matters (PM) and gaseous pollutants between laboratories, to identify microbial contaminants via bacterial counts as well as scientific bacterial-kits species identification and to correlate the relationship of physical IAQ characteristics, airborne pollutants and microbial contaminants between different laboratory settings within the same building which are Natural Product (NP) laboratory, Plant Tissue Culture (PTC) laboratory, and Microbiology laboratory. The physical IAQ characteristics and airborne PM was measured using VelociCalc multi-function ventilation meter 9565 and DustMate environmental dust detector respectively. Surface Air System Indoor Air Quality (SAS IAQ) was used to capture the microbial contaminants and after that bacterial counting and identification were done. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practice on Indoor Air Quality (ICOP) (2010) regulated by the Department of Occupational Safety and Health (DOSH). The temperature of PTC laboratory, velocity of NP laboratory and Microbiology laboratory, the respirable particulate matter (PM) of all three laboratories and Colony Forming Unit (CFU) count of PTC and NP laboratory exceeded the standard limit regulated by DOSH. This study demonstrated that Gemella morbillorum is the common bacterial species available in the environment with poor IAQ and there is a significant relationship between physical characteristics, airborne pollutants and microbial contaminants between the different types of laboratory settings. In conclusion, priority should be given to NP laboratory as it is exposed to poor IAQ conditions and immediate action should be taken to eliminate the problems.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [21] INDOOR AIR-QUALITY (IAQ), POLLUTANTS, THEIR SOURCES AND CONCENTRATION LEVELS
    NAMIESNIK, J
    GORECKI, T
    KOZDRONZABIEGALA, B
    LUKASIAK, J
    BUILDING AND ENVIRONMENT, 1992, 27 (03) : 339 - 356
  • [22] Indoor Air Quality (IAQ) Management in Hong Kong: The Way Forward
    Tsang, Tsz-Wun
    Mui, Kwok-Wai
    Wong, Ling-Tim
    ATMOSPHERE, 2024, 15 (05)
  • [23] How do children perceive indoor air quality (IAQ) at school?
    Simoni, Marzia
    Baldacci, Sandra
    Canciani, Mario
    Pini, Carlo
    Brunetti, Luigia Maria
    Indinnimeo, Luciana
    Carrer, Paolo
    Biggeri, Anibale
    Sestini, Piersante
    Maio, Sara
    Cerrai, Sonia
    Sarno, Giuseppe
    Cibella, Fabio
    Viegi, Giovanni
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [24] LABORATORY FACILITY DESIGN AND MICROBIAL INDOOR AIR QUALITY IN SELECTED HOSPITAL LABORATORIES
    Luksamijarulkul, Pipat
    Kiennukul, Nuchanard
    Vatthanasomboon, Pisit
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2014, 45 (03) : 746 - 755
  • [25] CO2 Purify Effect on Improvement of Indoor Air Quality (IAQ) through Indoor Vertical Greening
    Su, Ying-Ming
    Lin, Chia-Hui
    WORLD CONGRESS ON ENGINEERING - WCE 2013, VOL II, 2013, : 953 - +
  • [26] Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools
    Andualem, Zewudu
    Gizaw, Zemichael
    Bogale, Laekemariam
    Dagne, Henok
    MULTIDISCIPLINARY RESPIRATORY MEDICINE, 2019, 14
  • [27] A new eye to see the indoor air quality (IAQ) - Transport process visualization
    Deng, QH
    Tang, GF
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 101 - 108
  • [28] Tips for Assessing Indoor Air Quality RECOMMENDED PROTOCOL FOR REGULAR IAQ ASSESSMENT
    McLeod, Vince
    Lab Manager, 2020, 15 (02): : 30 - 33
  • [29] MICROBIAL AIR CONTAMINATION IN INDOOR ENVIRONMENT OF UNIVERSITY SPORTS HALL
    Onet, A.
    Ilies, D. C.
    Buhas, S.
    Rahota, D.
    Ilies, A.
    Baias, S.
    Marcu, F.
    Herman, G. V.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2018, 19 (02): : 694 - 703
  • [30] A study of the impact of attacked facades on microbial contamination of the indoor air
    Kukletova, I.
    INTERNATIONAL CONFERENCE BUILDING MATERIALS, PRODUCTS AND TECHNOLOGIES, ICBMPT 2022, 2022, 2341