INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY (IAQ) CHARACTERISTICS AT DIFFERENT LABORATORY CONDITIONS

被引:0
|
作者
Hazrin, A. H. [1 ]
Syazana, Anis A. A. [1 ]
Hadry, Noor Faizul N. [1 ]
Norhidayah, A. [2 ]
Shukri, Mohd M. A. [1 ]
机构
[1] Int Islam Univ Malaysia, Dept Biotechnol, Kulliyyah Sci, Kuantan Campus, Pahang, Malaysia
[2] Univ Malaysia Pahang, Fac Technol, Dept Occupat Safety & Hlth, Gambang, Pahang, Malaysia
来源
JURNAL TEKNOLOGI | 2015年 / 77卷 / 24期
关键词
Indoor air quality (IAQ); laboratory; airborne pollutants; particulate matter (PM); microbes; CFU;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Laboratory usually refers to a room or building equipped with chemicals and biological agents for scientific experimentation and research. Due to its own indoor hazards and its cause of health implications, it is an urge to assess and to understand the physical indoor air quality (IAQ) characteristics in the laboratory and the variables affecting the degree of exposure to occupants. The main objectives of this study was aimed to assess and to compare the physical IAQ characteristics and airborne pollutants including particulate matters (PM) and gaseous pollutants between laboratories, to identify microbial contaminants via bacterial counts as well as scientific bacterial-kits species identification and to correlate the relationship of physical IAQ characteristics, airborne pollutants and microbial contaminants between different laboratory settings within the same building which are Natural Product (NP) laboratory, Plant Tissue Culture (PTC) laboratory, and Microbiology laboratory. The physical IAQ characteristics and airborne PM was measured using VelociCalc multi-function ventilation meter 9565 and DustMate environmental dust detector respectively. Surface Air System Indoor Air Quality (SAS IAQ) was used to capture the microbial contaminants and after that bacterial counting and identification were done. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practice on Indoor Air Quality (ICOP) (2010) regulated by the Department of Occupational Safety and Health (DOSH). The temperature of PTC laboratory, velocity of NP laboratory and Microbiology laboratory, the respirable particulate matter (PM) of all three laboratories and Colony Forming Unit (CFU) count of PTC and NP laboratory exceeded the standard limit regulated by DOSH. This study demonstrated that Gemella morbillorum is the common bacterial species available in the environment with poor IAQ and there is a significant relationship between physical characteristics, airborne pollutants and microbial contaminants between the different types of laboratory settings. In conclusion, priority should be given to NP laboratory as it is exposed to poor IAQ conditions and immediate action should be taken to eliminate the problems.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [31] Internet of Things (IoT) and Indoor Air Quality (IAQ) Monitoring in the Health Domain
    John, Reena
    Kureshi, Rameez Raja
    Thakker, Dhavalkumar
    Mishra, Bhupesh Kumar
    11TH INTERNATIONAL CONFERENCE ON THE INTERNET OF THINGS, IOT 2021, 2021, : 215 - 218
  • [32] Indoor air quality (IAQ) evaluation of a Novel Tobacco Vapor (NTV) product
    Ichitsubo, Hirokazu
    Kotaki, Misato
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2018, 92 : 278 - 294
  • [33] IAQ 2016: Defining indoor air quality: Policy, standards and best practices
    Bahnfleth, William P.
    Sekhar, Chandra
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (02) : 115 - 117
  • [34] An implementation choice of assessment parameters for indoor air quality (IAQ) in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    Chan, W-Y.
    FACILITIES, 2009, 27 (5-6) : 202 - 210
  • [35] Influence of indoor air quality (IAQ) objectives on air-conditioned offices in Hong Kong
    Pui-Shan Hui
    Kwok-Wai Mui
    Ling-Tim Wong
    Environmental Monitoring and Assessment, 2008, 144 : 315 - 322
  • [36] Influence of indoor air quality (IAQ) objectives on air-conditioned offices in Hong Kong
    Hui, Pui-Shan
    Mui, Kwok-Wai
    Wong, Ling-Tim
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2008, 144 (1-3) : 315 - 322
  • [37] Indoor Air Quality Assessment on Polygons for Solid Municipal Waste for Microbial Contamination and a Method of Cleaning It
    Vorobyev, K. V.
    Chusov, A. N.
    Politaeva, N. A.
    Shchur, A. V.
    BIOLOGY BULLETIN, 2023, 50 (10) : 2690 - 2697
  • [38] Indoor Air Quality Assessment on Polygons for Solid Municipal Waste for Microbial Contamination and a Method of Cleaning It
    K. V. Vorobyev
    A. N. Chusov
    N. A. Politaeva
    A. V. Shchur
    Biology Bulletin, 2023, 50 : 2690 - 2697
  • [39] Indoor air quality in X's University Libraries (Physical, chemical and microbial aspects)
    Fitria, Laila
    Wulandari, Ririn Arminsih
    Hermawati, Ema
    Susanna, Dewi
    MAKARA JOURNAL OF HEALTH RESEARCH, 2008, 12 (02): : 76 - 82
  • [40] Indoor Environmental Parameters: Considering Measures of Microbial Ecology in the Characterization of Indoor Air Quality
    Mankiewicz, Phoebe
    Ciardullo, Christina
    Theodoridis, Andreas
    Henaff, Elizabeth
    Dyson, Anna
    INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1, 2021,