Indoor Air Quality Assessment on Polygons for Solid Municipal Waste for Microbial Contamination and a Method of Cleaning It

被引:0
|
作者
Vorobyev, K. V. [1 ]
Chusov, A. N. [1 ]
Politaeva, N. A. [1 ]
Shchur, A. V. [2 ]
机构
[1] Peter Great St Petersburg Polytech Univ, St Petersburg 195251, Russia
[2] Belarusian Russian Univ, Mogilev 212000, BELARUS
关键词
indoor air; apparatus-biological complex; air purification; microbial pollution; dust particles; landfill; adhesion; Tradescantia fluminensis; AIRBORNE MICROORGANISMS; LANDFILL; FACILITIES; EMISSIONS; EXPOSURE; COMPOST; WORKERS; SITES; URBAN; ODOR;
D O I
10.1134/S106235902310028X
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Landfill biogas contains large amounts of toxic and harmful impurities and may be a source of microbiological contamination of both the complex municipal waste landfill itself and adjacent territories. This paper uses modern biotechnologies designed to protect the environment to study the quantitative and qualitative composition of biogas for harmful factors, as well as for harmful substance removal from biogas. An assessment was made of air purification in the premises near landfills and adjacent territories using green plantations and a biological system based on an apparatus-biological complex for purification from microbiological contamination. The data obtained in our laboratory studies show that such apparatus-biological complexes can reduce the negative influence on the personnel and workers at operative points and on the inhabitants of adjacent territories by air purification.
引用
收藏
页码:2690 / 2697
页数:8
相关论文
共 50 条
  • [1] Indoor Air Quality Assessment on Polygons for Solid Municipal Waste for Microbial Contamination and a Method of Cleaning It
    K. V. Vorobyev
    A. N. Chusov
    N. A. Politaeva
    A. V. Shchur
    Biology Bulletin, 2023, 50 : 2690 - 2697
  • [2] ASSESSMENT OF THE MICROBIOLOGICAL CONTAMINATION OF AIR IN A MUNICIPAL SOLID WASTE TREATMENT COMPANY
    Wolny-Koladka, Katarzyna
    Malinowski, Mateusz
    ECOLOGICAL CHEMISTRY AND ENGINEERING A-CHEMIA I INZYNIERIA EKOLOGICZNA A, 2015, 22 (02): : 175 - 183
  • [3] Cleaning for improved indoor air quality: An initial assessment of effectiveness
    Franke, DL
    Cole, EC
    Leese, KE
    Foarde, KK
    Berry, MA
    INDOOR AIR, 1997, 7 (01) : 41 - 54
  • [4] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Kadaifciler, Duygu Goksay
    Cotuk, Aysin
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (06) : 3431 - 3444
  • [5] Microbial contamination of dental unit waterlines and effect on quality of indoor air
    Duygu Göksay Kadaifciler
    Aysin Cotuk
    Environmental Monitoring and Assessment, 2014, 186 : 3431 - 3444
  • [6] Assessment of Subsurface Contamination Potential of Municipal Solid Waste (MSW) Dumps
    Datta M.
    Kumar A.
    Indian Geotechnical Journal, 2017, 47 (4) : 410 - 420
  • [7] Air quality permitting considerations for municipal solid waste landfills
    Ricks, NR
    Freiburger, SF
    PROCEEDINGS FROM SWANA'S 20TH ANNUAL LANDFILL GAS SYMPOSIUM, 1997, : 1 - 26
  • [8] Odour and VOC impact assessment and air quality monitoring program at a municipal solid waste landfill
    Leduc, R.
    Fecil, B.
    Leconte, C. E.
    Normandin, Y.
    Page, T.
    WATER PRACTICE AND TECHNOLOGY, 2009, 4 (02):
  • [9] Surface Microbial Contamination and Air Quality before and after Regular Cleaning Procedures
    Mohammed, Mohammed O. A.
    ATMOSPHERE, 2023, 14 (02)
  • [10] Assessment of Microbial Contamination in Indoor Air of Private Maternity Homes in Moga, Punjab
    Kumar, Harsh
    Kaur, Amandeep
    Kaur, Bhavneet
    Gupta, Ramesh Kumar
    Dhanjal, Daljeet Singh
    Zahoor, Uzain
    Palaha, Rajdeep
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (05) : DC1 - DC5