A Review of Selected Types of Indoor Air Purifiers in Terms of Microbial Air Contamination Reduction

被引:20
|
作者
Szczotko, Maciej [1 ]
Orych, Izabela [1 ]
Maka, Lukasz [1 ]
Solecka, Jolanta [1 ]
机构
[1] Natl Res Inst, NIH, Dept Environm Hlth & Safety, Natl Inst Publ Hlth, PL-00791 Warsaw, Poland
关键词
indoor air; air purifiers; air cleaners; indoor air contamination; air filtration; UV; cold plasma; PCO; ULTRAVIOLET PHOTOCATALYTIC OXIDATION; AIRBORNE BACTERIA; GERMICIDAL IRRADIATION; EXPOSURE ASSESSMENT; RAPID INACTIVATION; RELATIVE-HUMIDITY; BUILT ENVIRONMENT; PLASMA; DISINFECTION; VENTILATION;
D O I
10.3390/atmos13050800
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Aims: With the ongoing pandemic and increased interest in measures to improve indoor air quality, various indoor air purifiers have become very popular and are widely used. This review presents the advantages and disadvantages of various types of technologies used in air purifiers in terms of reducing microbial contamination. Methods: A literature search was performed using Web of Science, Scopus, and PubMed, as well as technical organizations dealing with indoor air-quality to identify research articles and documents within our defined scope of interest. Relevant sections: The available literature data focus mainly on the efficiency of devices based on tests conducted in laboratory conditions with test chambers, which does not reflect the real dimensions and conditions observed in residential areas. According to a wide range of articles on the topic, the actual effectiveness of air purifiers is significantly lower in real conditions than the values declared by the manufacturers in their marketing materials as well as technical specifications. Conclusions: According to current findings, using indoor air purifiers should not be the only measure to improve indoor air-quality; however, these can play a supporting role if their application is preceded by an appropriate technical and environmental analysis considering the real conditions of its use.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Indoor Air Quality Control for Airborne Diseases: A Review on Portable UV Air Purifiers
    Sankurantripati, Shriram
    Duchaine, Florent
    FLUIDS, 2024, 9 (12)
  • [2] Rating of mobile indoor air purifiers
    Finger, H.
    Schneiderwind, U.
    Asbach, C.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2015, 75 (11-12): : 497 - 502
  • [4] INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY CHARACTERISTICS AT SELECTED LIBRARIES IN PAHANG
    Hizrri, A.
    Khadijah, H.
    Hadry, Noor Faizul N.
    Norhidayah, A.
    Shukri, Mohd M. A.
    JURNAL TEKNOLOGI, 2015, 77 (24): : 51 - 56
  • [5] Effects of Indoor Air Purifiers on Children with Asthma
    Lee, Ga Hee
    Kim, Jeong Hee
    Kim, Sungroul
    Lee, Sangwoon
    Lim, Dae Hyun
    YONSEI MEDICAL JOURNAL, 2020, 61 (04) : 310 - 316
  • [6] Microbial air contamination in indoor environment of a university library
    Kalwasinska, Agnieszka
    Burkowska, Aleksandra
    Wilk, Iwona
    ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2012, 19 (01) : 25 - 29
  • [7] The perception of air purifiers on indoor air quality: effective or human herd behavior?
    Ifta Irodatul Utami
    Wishnu Agung Baroto
    City and Built Environment, 3 (1):
  • [8] Efficiency and Eco-Costs of Air Purifiers in Terms of Improving Microbiological Indoor Air Quality in Dwellings-A Case Study
    Bragoszewska, Ewa
    Bogacka, Magdalena
    Pikon, Krzysztof
    ATMOSPHERE, 2019, 10 (12)
  • [9] Photocatalytic air purifiers for indoor air: European standard and pilot room experiments
    Costarramone, N.
    Cantau, C.
    Desauziers, V.
    Pecheyran, C.
    Pigot, T.
    Lacombe, S.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (14) : 12538 - 12546
  • [10] MICROBIAL AIR CONTAMINATION IN INDOOR ENVIRONMENT OF UNIVERSITY SPORTS HALL
    Onet, A.
    Ilies, D. C.
    Buhas, S.
    Rahota, D.
    Ilies, A.
    Baias, S.
    Marcu, F.
    Herman, G. V.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2018, 19 (02): : 694 - 703