INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY CHARACTERISTICS AT SELECTED LIBRARIES IN PAHANG

被引:0
|
作者
Hizrri, A. [1 ]
Khadijah, H. [1 ]
Hadry, Noor Faizul N. [1 ]
Norhidayah, A. [2 ]
Shukri, Mohd M. A. [1 ]
机构
[1] Int Islam Univ Malaysia, Kulliyyah Sci, Dept Biotechnol, Kuantan Campus, Pahang, Malaysia
[2] Univ Malaysia Pahang, Fac Technol, Dept Occupat Safety & Hlth, Pahang, Malaysia
来源
JURNAL TEKNOLOGI | 2015年 / 77卷 / 24期
关键词
Indoor air quality (IAQ); library; airborne pollutants; particulate matter (PM); CFU microbes; Aerococcus viridans;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Library contains huge collection of books that can undergo biodeterioration process after period of time. Due to this biological reaction, the existence of airborne particulate matters and microbes in the air of the library can be disturbed and elevated, thus can cause health implications to occupants. Therefore, it is an urge to assess and understand the correlation between physical indoor air quality (IAQ) characteristics, airborne pollutants and microbial contaminants in different library settings and locations. This study was carried out at three different libraries, which are Library A (Gambang as suburban area), Library B (Kuantan as urban area) and Library C (Pekan as rural area). The physical IAQ characteristics and particulate matter (PM) monitoring were assessed by using IAQ Meter and DustMate respectively. Surface Air System IAQ (SAS IAQ) was used to collect the airborne microbes. The microbial contamination was further assessed and identified in the laboratory by using API 20E and API 20 Strep while SPSS was used to analyze the relationship of physical IAQ characteristics, airborne pollutants and airborne microbes contaminants. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practise on Indoor Air Quality, 2010 (ICOP, 2010) regulated by the Department of Occupational Safety and Health (DOSH). Respirable PM in Library A and CFU counts in Library A and C exceeded the standard limit with the value of 0.30 mg/m(3), 2744 CFU/m(3) and 1833 CFU/m(3) respectively. Significant differences (p < 0.05) between the selected libraries were observed among relative humidity (p=0.001), inhalable PM (p=0.001), thoracic PM (p=0.001), respirable PM (p= 0.01), CO2 reading (p=0.001) and CFU counts (p= 0.01). This study demonstrated Library C has poor air quality as the reading for CO2 and CFU counts are very high compared with the other two libraries. The bacterial identification findings indicated that Gram positive bacteria were abundant compared to Gram negative bacteria. Aerococcus viridans is the most dominant type of bacteria isolated in all the libraries.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [41] Assessment of indoor and outdoor microbial air quality of cafeterias of an educational institute
    Asif, Ayesha
    Zeeshan, Muhammad
    Jahanzaib, Muhammad
    [J]. ATMOSPHERIC POLLUTION RESEARCH, 2019, 10 (02) : 531 - 536
  • [42] AIR CLEANING EQUIPMENT - ITS EFFECT UPON QUALITY OF INDOOR AIR
    KLOTZ, F
    WANNER, HU
    [J]. ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIES A-MEDICAL MICROBIOLOGY INFECTIOUS DISEASES VIROLOGY PARASITOLOGY, 1974, 227 (1-4): : 559 - 563
  • [43] Indoor Air Quality and Sick Building Syndrome in Three Selected Buildings
    Norhidayah, A.
    Chia-Kuang, Lee
    Azhar, M. K.
    Nurulwahida, S.
    [J]. MALAYSIAN TECHNICAL UNIVERSITIES CONFERENCE ON ENGINEERING & TECHNOLOGY 2012 (MUCET 2012), 2013, 53 : 93 - 98
  • [44] Indoor and outdoor microbiological air quality in naturally and mechanically ventilated university libraries
    Hassan, Ahmad
    Zeeshan, Muhammad
    Bhatti, Muhammad Faraz
    [J]. ATMOSPHERIC POLLUTION RESEARCH, 2021, 12 (08)
  • [45] Microbial contamination of indoor air due to leakages from crawl space:: a field study
    Airaksinen, M
    Pasanen, P
    Kurnitski, J
    Seppänen, O
    [J]. INDOOR AIR, 2004, 14 (01) : 55 - 64
  • [46] Effect of Window Characteristics on Indoor Air Quality in Residential Housing
    Li, Xianli
    You, Shijun
    Xia, Ying
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 3695 - +
  • [47] The Microbial Activity in PM2.5 in Indoor Air: As an Index of Air Quality Level
    Chen, Hanlin
    Du, Rui
    Ren, Weishan
    Zhang, Sujian
    Du, Pengrui
    Zhang, Yongtao
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2021, 21 (02) : 1 - 13
  • [48] Indoor air quality and health - Does fungal contamination play a significant role?
    Bardana, EJ
    [J]. IMMUNOLOGY AND ALLERGY CLINICS OF NORTH AMERICA, 2003, 23 (02) : 291 - +
  • [49] Contribution to indoor air quality monitoring in relation to health status of children
    Kubinova, R
    Kazmarova, H
    Kotlik, B
    Kratenova, J
    [J]. EPIDEMIOLOGY, 2001, 12 (04) : S66 - S66
  • [50] Experimental and statistical analysis of indoor air quality characteristics in an air conditioned car
    Thirumal, P.
    Amirthagadeswaran, K.S.
    Jayabal, S.
    [J]. Nature Environment and Pollution Technology, 2014, 13 (01) : 11 - 18