INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY CHARACTERISTICS AT SELECTED LIBRARIES IN PAHANG

被引:0
|
作者
Hizrri, A. [1 ]
Khadijah, H. [1 ]
Hadry, Noor Faizul N. [1 ]
Norhidayah, A. [2 ]
Shukri, Mohd M. A. [1 ]
机构
[1] Int Islam Univ Malaysia, Kulliyyah Sci, Dept Biotechnol, Kuantan Campus, Pahang, Malaysia
[2] Univ Malaysia Pahang, Fac Technol, Dept Occupat Safety & Hlth, Pahang, Malaysia
来源
JURNAL TEKNOLOGI | 2015年 / 77卷 / 24期
关键词
Indoor air quality (IAQ); library; airborne pollutants; particulate matter (PM); CFU microbes; Aerococcus viridans;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Library contains huge collection of books that can undergo biodeterioration process after period of time. Due to this biological reaction, the existence of airborne particulate matters and microbes in the air of the library can be disturbed and elevated, thus can cause health implications to occupants. Therefore, it is an urge to assess and understand the correlation between physical indoor air quality (IAQ) characteristics, airborne pollutants and microbial contaminants in different library settings and locations. This study was carried out at three different libraries, which are Library A (Gambang as suburban area), Library B (Kuantan as urban area) and Library C (Pekan as rural area). The physical IAQ characteristics and particulate matter (PM) monitoring were assessed by using IAQ Meter and DustMate respectively. Surface Air System IAQ (SAS IAQ) was used to collect the airborne microbes. The microbial contamination was further assessed and identified in the laboratory by using API 20E and API 20 Strep while SPSS was used to analyze the relationship of physical IAQ characteristics, airborne pollutants and airborne microbes contaminants. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practise on Indoor Air Quality, 2010 (ICOP, 2010) regulated by the Department of Occupational Safety and Health (DOSH). Respirable PM in Library A and CFU counts in Library A and C exceeded the standard limit with the value of 0.30 mg/m(3), 2744 CFU/m(3) and 1833 CFU/m(3) respectively. Significant differences (p < 0.05) between the selected libraries were observed among relative humidity (p=0.001), inhalable PM (p=0.001), thoracic PM (p=0.001), respirable PM (p= 0.01), CO2 reading (p=0.001) and CFU counts (p= 0.01). This study demonstrated Library C has poor air quality as the reading for CO2 and CFU counts are very high compared with the other two libraries. The bacterial identification findings indicated that Gram positive bacteria were abundant compared to Gram negative bacteria. Aerococcus viridans is the most dominant type of bacteria isolated in all the libraries.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [31] Children's allergic diseases and microbial contamination of indoor air -: A case report
    Kasznia-Kocot, Joanna
    Lis, Danuta O.
    Kordys-Darmolinska, Bozena
    Grzybowska-Chlebowczyk, Urszula
    Wos, Halina
    Gorny, Rafal L.
    [J]. ANNALS OF AGRICULTURAL AND ENVIRONMENTAL MEDICINE, 2007, 14 (01) : 187 - 190
  • [32] The relation between fungal propagules in indoor air and home characteristics
    Ren, P
    Jankun, TM
    Belanger, K
    Bracken, MB
    Leaderer, BP
    [J]. ALLERGY, 2001, 56 (05) : 419 - 424
  • [33] Is CO2 a good proxy for indoor air quality in classrooms? Part 2: Health outcomes and perceived indoor air quality in relation to classroom exposure and building characteristics
    Chatzidiakou, Lia
    Mumovic, Dejan
    Summerfield, Alex
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2015, 36 (02): : 162 - 181
  • [34] Investigation of the Relationship Between Indoor Air Quality and Physical Activity
    Lawson, Christopher
    McCullagh, Paul
    Cruciani, Federico
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON UBIQUITOUS COMPUTING & AMBIENT INTELLIGENCE (UCAMI 2022), 2023, 594 : 547 - 558
  • [35] Analysis of fungal contamination in vehicle air filters and their impact as a bioaccumulator on indoor air quality
    Aquino, Simone
    Alves de Lima, Jose Eduardo
    Branco do Nascimento, Ana Paula
    Reis, Fabricio Caldeira
    [J]. AIR QUALITY ATMOSPHERE AND HEALTH, 2018, 11 (10): : 1143 - 1153
  • [36] Comparative study on indoor air quality in Japan and China: Characteristics of residential indoor and outdoor VOCs
    Ohura, Takeshi
    Amagai, Takashi
    Shen, Xueyou
    Li, Shuang
    Zhang, Ping
    Zhu, Lizhong
    [J]. ATMOSPHERIC ENVIRONMENT, 2009, 43 (40) : 6352 - 6359
  • [37] Analysis of fungal contamination in vehicle air filters and their impact as a bioaccumulator on indoor air quality
    Simone Aquino
    José Eduardo Alves de Lima
    Ana Paula Branco do Nascimento
    Fabrício Caldeira Reis
    [J]. Air Quality, Atmosphere & Health, 2018, 11 : 1143 - 1153
  • [38] Investigation of Indoor Air Quality in the Selected Ukraine Classroom - Case Study
    Kapalo, P.
    Klymenko, H.
    Zhelykh, V
    Adamski, M.
    [J]. PROCEEDINGS OF ADVANCES IN RESOURCE-SAVING TECHNOLOGIES AND MATERIALS IN CIVIL AND ENVIRONMENTAL ENGINEERING (CEE 2019), 2020, 47 : 168 - 173
  • [39] Comprehensive health risk assessment of microbial indoor air quality in microenvironments
    Kumar, Pradeep
    Singh, A. B.
    Singh, Rajeev
    [J]. PLOS ONE, 2022, 17 (02):
  • [40] Study of the indoor air quality in hospitals in Chennai, India - Microbial profile
    Sudharsanam, Suchithra
    Srikanth, Padma
    Sheela, Merline
    Steinberg, Ralf
    [J]. INDOOR AND BUILT ENVIRONMENT, 2008, 17 (05) : 435 - 441