INDOOR MICROBIAL CONTAMINATION AND ITS RELATION TO PHYSICAL INDOOR AIR QUALITY CHARACTERISTICS AT SELECTED LIBRARIES IN PAHANG

被引:0
|
作者
Hizrri, A. [1 ]
Khadijah, H. [1 ]
Hadry, Noor Faizul N. [1 ]
Norhidayah, A. [2 ]
Shukri, Mohd M. A. [1 ]
机构
[1] Int Islam Univ Malaysia, Kulliyyah Sci, Dept Biotechnol, Kuantan Campus, Pahang, Malaysia
[2] Univ Malaysia Pahang, Fac Technol, Dept Occupat Safety & Hlth, Pahang, Malaysia
来源
JURNAL TEKNOLOGI | 2015年 / 77卷 / 24期
关键词
Indoor air quality (IAQ); library; airborne pollutants; particulate matter (PM); CFU microbes; Aerococcus viridans;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Library contains huge collection of books that can undergo biodeterioration process after period of time. Due to this biological reaction, the existence of airborne particulate matters and microbes in the air of the library can be disturbed and elevated, thus can cause health implications to occupants. Therefore, it is an urge to assess and understand the correlation between physical indoor air quality (IAQ) characteristics, airborne pollutants and microbial contaminants in different library settings and locations. This study was carried out at three different libraries, which are Library A (Gambang as suburban area), Library B (Kuantan as urban area) and Library C (Pekan as rural area). The physical IAQ characteristics and particulate matter (PM) monitoring were assessed by using IAQ Meter and DustMate respectively. Surface Air System IAQ (SAS IAQ) was used to collect the airborne microbes. The microbial contamination was further assessed and identified in the laboratory by using API 20E and API 20 Strep while SPSS was used to analyze the relationship of physical IAQ characteristics, airborne pollutants and airborne microbes contaminants. The scientific method protocol and standard reference limits were compared based on Industrial Code of Practise on Indoor Air Quality, 2010 (ICOP, 2010) regulated by the Department of Occupational Safety and Health (DOSH). Respirable PM in Library A and CFU counts in Library A and C exceeded the standard limit with the value of 0.30 mg/m(3), 2744 CFU/m(3) and 1833 CFU/m(3) respectively. Significant differences (p < 0.05) between the selected libraries were observed among relative humidity (p=0.001), inhalable PM (p=0.001), thoracic PM (p=0.001), respirable PM (p= 0.01), CO2 reading (p=0.001) and CFU counts (p= 0.01). This study demonstrated Library C has poor air quality as the reading for CO2 and CFU counts are very high compared with the other two libraries. The bacterial identification findings indicated that Gram positive bacteria were abundant compared to Gram negative bacteria. Aerococcus viridans is the most dominant type of bacteria isolated in all the libraries.
引用
收藏
页码:51 / 56
页数:6
相关论文
共 50 条
  • [21] Microbial cell wall constituents in indoor air and their relation to disease
    Rylander, R
    [J]. INDOOR AIR, 1998, : 59 - 65
  • [22] Subjective indoor air quality in schools in relation to exposure
    Smedje, G
    Norback, D
    Edling, C
    [J]. INDOOR AIR, 1997, 7 (02) : 143 - 150
  • [23] Topical Issue on Simulation of Indoor Environmental Quality: Selected Papers from Indoor Air 2014
    Wan, Man Pun
    Lin, Zhang
    [J]. BUILDING SIMULATION, 2015, 8 (04) : 369 - 370
  • [24] Indoor air quality in the Swedish housing stock and its dependence on building characteristics
    Langer, Sarka
    Beko, Gabriel
    [J]. BUILDING AND ENVIRONMENT, 2013, 69 : 44 - 54
  • [25] Physical parameters influence the microbial quality of indoor air in research laboratories: A report from Malaysia
    Yogeswaran, Kuilan
    Azmi, Liyana
    Bhassu, Subha
    Isa, Hafizah N.
    Aziz, Muhamad Afiq
    [J]. KUWAIT JOURNAL OF SCIENCE, 2023, 50 (04) : 665 - 673
  • [26] Assessment of Selected Interior Flooring Materials On Indoor Air Quality
    Senitkova, Ingrid Juhasova
    Kraus, Michal
    [J]. WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM 2016, WMCAUS 2016, 2016, 161 : 1527 - 1531
  • [27] Assessing physical conditions of indoor space enclosing elements in schools in relation to their indoor environmental quality
    Sadick, Abdul-Manan
    Issa, Mohamed H.
    [J]. JOURNAL OF BUILDING ENGINEERING, 2018, 20 : 520 - 530
  • [28] INDOOR AIR-QUALITY AND CLIMATE OF DWELLINGS IN RELATION TO SUBJECTIVE RATINGS OF INDOOR QUALITY BY HEALTH IMPAIRED INHABITANTS
    KOLLER, M
    GROLLKNAPP, E
    HAIDER, M
    KUNDI, M
    STIDL, HG
    POPP, W
    [J]. ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1993, 194 (5-6): : 508 - 524
  • [29] Assessment of Microbial Contamination in Indoor Air of Private Maternity Homes in Moga, Punjab
    Kumar, Harsh
    Kaur, Amandeep
    Kaur, Bhavneet
    Gupta, Ramesh Kumar
    Dhanjal, Daljeet Singh
    Zahoor, Uzain
    Palaha, Rajdeep
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (05) : DC1 - DC5
  • [30] Investigation of fungal contamination of indoor air in homes of selected patients with asthma bronchiale
    Senkpiel, K
    Kurowski, V
    Ohgke, H
    [J]. ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1996, 198 (03): : 191 - 203