To determine the source dwell positions of HDR brachytherapy using 2D 729 ion chamber array

被引:1
|
作者
Kumar, S. [1 ]
Gangadharan, Sitha [2 ]
Cheruparambil, Aswathi [2 ]
Parakat, Anjana [2 ]
Perumangat, Aparna [2 ]
机构
[1] Malabar Canc Ctr, Div Radiat Phys, Dept Radiat Oncol, Thalassery 670103, Kerala, India
[2] Univ Calicut, Dept Phys, Malappuram, Kerala, India
关键词
afterloading; applicators; HDR brachytherapy; 2D array;
D O I
10.1017/S1460396915000382
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine the dwell position of a high-dose- rate (HDR) brachytherapy Ir-192 source using a PTW Seven29 2D detector array. A Nucletron Microselectron HDR device and 2D array ionisation chamber, equipped with 729 ionisation chambers uniformly arranged in a 27 x 27 matrix with an active array area of 27 x 27 cm(2), were used for this study. Different dwell positions were assigned in the HDR machine. Rigid interstitial needles and a vaginal applicator were positioned on the 2D array, which was then exposed according to the programmed dwell positions. Subsequently, the positional accuracy of the source position was analysed. This process was repeated for different dwell positions. The results were analysed using an in-house- developed Excel programme. Different random dwell position checks as well as dwell position measurements were performed using a radiochromic film. The dwell positions measured by the 2D array were found to be in good agreement with those measured by the film. The standard deviations between the doses obtained from the different dwell positions were 0.191828, 0.329973, 0.370632 and 0.779939, whereas the corresponding standard deviations of the doses at the vaginal cylinder were 0.60303, 0.242808, 0.242808 and 0.065309. When the planned and measured dwell positions were plotted, a linear relationship was obtained.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 50 条
  • [41] A method to enhance 2D ion chamber array patient specific quality assurance for IMRT
    Diaz Moreno, Rogelio Manuel
    Venencia, Daniel
    Garrigo, Edgardo
    Pipman, Yakov
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 145 - 151
  • [42] A 2D Ion Chamber Array Detector as a QA Device for Spot Scanning Proton Beams
    Arjomandy, B.
    Gillin, M.
    Zhu, X.
    Sahoo, N.
    Ciangaru, G.
    Bues, M.
    Poenisch, F.
    Ding, X.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [43] Portal dosimetry for pretreatment verification of IMRT plan: a comparison with 2D ion chamber array
    Sharma, Dayananda Shamurailatpam
    Mhatre, Vaibav
    Heigrujam, Malhotra
    Talapatra, Kaustav
    Mallik, Suman
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (04): : 238 - 248
  • [44] Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification
    Saminathan, Sathiyan
    Manickan, Ravikumar
    Chandraraj, Varatharaj
    Supe, Sanjay S.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (02): : 116 - 127
  • [45] A method to enhance spatial resolution of a 2D ion chamber array for quality control of MLC
    Diaz Moreno, Rogelio
    Venencia, Daniel
    Garrigo, Edgardo
    Pipman, Yakov
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 63 - 73
  • [46] FEASIBILITY STUDY OF A 2D ION CHAMBER ARRAY AND THE MULTICUBE PHANTOM FOR QUALITY ASSURANCE OF RAPIDARC
    Bocanek, J.
    Gomola, I.
    Depuydt, T.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S446 - S446
  • [47] Dose-space mapping study on 2D ion-chamber array in radiotherapy
    Du Q.
    Wu Z.-F.
    1875, Atomic Energy Press (50): : 1875 - 1880
  • [48] A 2D ion chamber array audit of wedged and asymmetric fields in an inhomogeneous lung phantom
    Lye, Jessica
    Kenny, John
    Lehmann, Joerg
    Dunn, Leon
    Kron, Tomas
    Alves, Andrew
    Cole, Andrew
    Williams, Ivan
    MEDICAL PHYSICS, 2014, 41 (10)
  • [49] Reducing dysphagia with palliative 2D HDR brachytherapy improves survival in esophageal cancer
    Burchardt, W.
    Chyrek, A.
    Skowronek, J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S592 - S592
  • [50] Dosimetric plan verification using a 2D ionization chamber array in helical IMRT
    Yango, A.
    Schoroth, F.
    Muedder, T.
    Poppe, B.
    Garbe, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 108 - 109