Non-enzymatic hydrogen peroxide sensor based on a gold electrode modified with granular cuprous oxide nanowires

被引:2
|
作者
Zhongke Yan
Jianwei Zhao
Lirong Qin
Fan Mu
Ping Wang
Xining Feng
机构
[1] Southwest University,School of Physical Science and Technology
来源
Microchimica Acta | 2013年 / 180卷
关键词
Template method; Cu; O; Nanowires; Hydrogen peroxide; Sensor;
D O I
暂无
中图分类号
学科分类号
摘要
Granular nanowires with a diameter of about 60 nm were fabricated from cuprous oxide (Cu2O) by an electrochemical method using anodic aluminium oxide as the template. A non-enzymatic sensor for hydrogen peroxide (H2O2) was then developed on the basis of a gold electrode modified with Cu2O nanowires and Nafion. The resulting sensor enables the determination of H2O2 with a sensitivity of 745 μA mM−1 cm−2, over a wide linear range (0.25 μM to 5.0 mM), and with a low detection limit (0.12 μM). The results demonstrate that the use of such granular nanowires provides a promising tool for the design of non-enzymatic chemical sensors.
引用
收藏
页码:145 / 150
页数:5
相关论文
共 50 条
  • [41] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Chandrasekaran Priya
    Sriraman Anuja
    Mani Devendiran
    Rajendran Suresh Babu
    Sangilimuthu Sriman Narayanan
    [J]. Ionics, 2024, 30 : 2869 - 2880
  • [42] A flexible and disposable hybrid electrode based on Cu nanowires modified graphene transparent electrode for non-enzymatic glucose sensor
    Fan, Zengjie
    Liu, Bin
    Liu, Xiaohong
    Li, Zhangpeng
    Wang, Honggang
    Yang, Shengrong
    Wang, Jinqing
    [J]. ELECTROCHIMICA ACTA, 2013, 109 : 602 - 608
  • [43] Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires
    Min-Jung Song
    Sung Woo Hwang
    Dongmok Whang
    [J]. Journal of Applied Electrochemistry, 2010, 40 : 2099 - 2105
  • [44] A new modified electrode based on Ag-doped mesoporous SBA-16 nanoparticles as non-enzymatic sensor for hydrogen peroxide
    Azizi, Seyed Naser
    Ghasemi, Shahram
    Samadi-Maybodi, Abdolraoof
    Ranjbar-Azad, Mohammad
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 : 271 - 278
  • [45] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [46] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Huaan Zhong
    Ruo Yuan
    Yaqin Chai
    Yu Zhang
    Chengyan Wang
    Feng Jia
    [J]. Microchimica Acta, 2012, 176 : 389 - 395
  • [47] Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires
    Song, Min-Jung
    Hwang, Sung Woo
    Whang, Dongmok
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (12) : 2099 - 2105
  • [48] Non-enzymatic sensor based on a glassy carbon electrode modified with Ag nanoparticles/polyaniline/halloysite nanotube nanocomposites for hydrogen peroxide sensing
    Yang, Ziyin
    Zheng, Xiaohui
    Zheng, Jianbin
    [J]. RSC ADVANCES, 2016, 6 (63) : 58329 - 58335
  • [49] An Improved Sensitivity Non-enzymatic Glucose Sensor Based on a Nano-Gold Modified Ag Electrode
    He Jia-hong
    Xu Qiang
    Gao Zhi-qiang
    Song Zhong-rong
    [J]. MICRO-NANO TECHNOLOGY XIII, 2012, 503 : 427 - 431
  • [50] Superficial fabrication of gold nanoparticles modified CuO nanowires electrode for non-enzymatic glucose detection
    Mishra, Ashwini Kumar
    Mukherjee, Bratindranath
    Kumar, Amit
    Jarwal, Deepak Kumar
    Ratan, Smrity
    Kumar, Chandan
    Jit, Satyabrata
    [J]. RSC ADVANCES, 2019, 9 (04): : 1772 - 1781