Non-enzymatic sensor based on a glassy carbon electrode modified with Ag nanoparticles/polyaniline/halloysite nanotube nanocomposites for hydrogen peroxide sensing

被引:35
|
作者
Yang, Ziyin [1 ]
Zheng, Xiaohui [1 ]
Zheng, Jianbin [1 ]
机构
[1] NW Univ Xian, Inst Analyt Sci, Shaanxi Prov Key Lab Electroanalyt Chem, Xian 710069, Shaanxi, Peoples R China
关键词
HALLOYSITE NANOTUBES; HIGH-PERFORMANCE; NANOPARTICLES; COMPOSITE; FABRICATION; REDUCTION; NANOWIRE;
D O I
10.1039/c6ra06366g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Ag nanoparticles/polyaniline/halloysite nanotube (AgNPs/PANI/HNTs) nanocomposites were synthesized and used for fabricating nonenzymatic H2O2 sensor. AgNPs/PANI/HNTs nanocomposites were synthesized through the direct loading of preformed AgNPs over the surface of PANI/HNTs. The morphology and composition of the nanocomposites were characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), energy-dispersive X-ray spectrum (EDX) and X-ray diffraction spectrum (XRD). SEM and TEM observations reveal that large numbers of AgNPs were distributed on the surface of PANI/HNTs. The electrochemical investigations indicate that the sensor based on AgNPs/PANI/HNT exhibited an excellent performance toward H2O2 with a wide linear range of 0.5 mu M to 4.7 mM, a high sensitivity of 74.8 mu A mM(-1) cm(-2) and a low detection limit of 0.3 mu M (S/N = 3).
引用
收藏
页码:58329 / 58335
页数:7
相关论文
共 50 条
  • [1] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [2] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Huaan Zhong
    Ruo Yuan
    Yaqin Chai
    Yu Zhang
    Chengyan Wang
    Feng Jia
    [J]. Microchimica Acta, 2012, 176 : 389 - 395
  • [3] A non-enzymatic sensor for hydrogen peroxide based on polyaniline, multiwalled carbon nanotubes and gold nanoparticles modified Au electrode
    Narang, Jagriti
    Chauhan, Nidhi
    Pundir, C. S.
    [J]. ANALYST, 2011, 136 (21) : 4460 - 4466
  • [4] A Non-Enzymatic Hydrogen Peroxide Sensor Based on Ag/MnOOH Nanocomposites
    Bai, Wushuang
    Zheng, Jianbin
    Sheng, Qinglin
    [J]. ELECTROANALYSIS, 2013, 25 (10) : 2305 - 2311
  • [5] Analytical sensing of hydrogen peroxide on Ag nanoparticles–multiwalled carbon nanotube-modified glassy carbon electrode
    Ahmadreza Afraz
    Amir Abbas Rafati
    Ali Hajian
    [J]. Journal of Solid State Electrochemistry, 2013, 17 : 2017 - 2025
  • [6] Non-enzymatic sensors based on a glassy carbon electrode modified with Au nanoparticles/polyaniline/SnO2 fibrous nanocomposites for nitrite sensing
    Duan, Chengqian
    Bai, Wushuang
    Zheng, Jianbin
    [J]. NEW JOURNAL OF CHEMISTRY, 2018, 42 (14) : 11516 - 11524
  • [7] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a composite consisting of chitosanaEuroencapsulated graphite and platinum nanoparticles
    Chen, Tse-Wei
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    [J]. MICROCHIMICA ACTA, 2016, 183 (11) : 2861 - 2869
  • [8] Non-enzymatic hydrogen peroxide sensor based on palladium-decorated poly(thionine) modified glassy carbon electrode
    Celebi, Mutlu Sonmez
    Kara, Songul Kirlak
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2024, 71 (05) : 482 - 492
  • [9] Analytical sensing of hydrogen peroxide on Ag nanoparticles-multiwalled carbon nanotube-modified glassy carbon electrode
    Afraz, Ahmadreza
    Rafati, Amir Abbas
    Hajian, Ali
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2013, 17 (07) : 2017 - 2025
  • [10] A Non-enzymatic Hydrogen Peroxide Sensor Based on CuO Nanoparticles/polyaniline on Flexible CNT Fiber Electrode
    Song, Min-Jung
    [J]. KOREAN CHEMICAL ENGINEERING RESEARCH, 2023, 61 (02): : 196 - 201