Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles

被引:1
|
作者
Huaan Zhong
Ruo Yuan
Yaqin Chai
Yu Zhang
Chengyan Wang
Feng Jia
机构
[1] Southwest University,Education Ministry Key Laboratory on Luminescence and Real
来源
Microchimica Acta | 2012年 / 176卷
关键词
Non-enzymatic sensor; Multi-wall carbon nanotube; Polyaniline; Platinum nanoparticles; Hydrogen peroxide;
D O I
暂无
中图分类号
学科分类号
摘要
We report on a non-enzymatic amperometric sensor for hydrogen peroxide (H2O2). It was fabricated by electrodeposition of multi-wall carbon nanotubes and polyaniline along with platinum nanoparticles on the surface of a glassy carbon electrode. The modification was probed by scanning electron microscopy and cyclic voltammetry. The resulting sensor exhibits a high sensitivity (748.4 μA·mM−1·cm−2), a wide linear range (7.0 μM–2.5 mM), a low detection limit (2.0 μM) (S/N = 3), a short response time (>5 s), and long-term stability, and is not interfered by common species. It was successfully applied to determine H2O2 in disinfectants.
引用
收藏
页码:389 / 395
页数:6
相关论文
共 50 条
  • [1] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [2] Non-enzymatic sensor based on a glassy carbon electrode modified with Ag nanoparticles/polyaniline/halloysite nanotube nanocomposites for hydrogen peroxide sensing
    Yang, Ziyin
    Zheng, Xiaohui
    Zheng, Jianbin
    [J]. RSC ADVANCES, 2016, 6 (63) : 58329 - 58335
  • [3] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a composite consisting of chitosanaEuroencapsulated graphite and platinum nanoparticles
    Chen, Tse-Wei
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    [J]. MICROCHIMICA ACTA, 2016, 183 (11) : 2861 - 2869
  • [4] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Guang Yin
    Ling Xing
    Xiu-Ju Ma
    Jun Wan
    [J]. Chemical Papers, 2014, 68 : 435 - 441
  • [5] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Yin, Guang
    Xing, Ling
    Ma, Xiu-Ju
    Wan, Jun
    [J]. CHEMICAL PAPERS, 2014, 68 (04): : 435 - 441
  • [6] A non-enzymatic sensor for hydrogen peroxide based on polyaniline, multiwalled carbon nanotubes and gold nanoparticles modified Au electrode
    Narang, Jagriti
    Chauhan, Nidhi
    Pundir, C. S.
    [J]. ANALYST, 2011, 136 (21) : 4460 - 4466
  • [7] Non-enzymatic sensing of hydrogen peroxide using a glassy carbon electrode modified with a composite consisting of chitosan‐encapsulated graphite and platinum nanoparticles
    Tse-Wei Chen
    Selvakumar Palanisamy
    Shen-Ming Chen
    [J]. Microchimica Acta, 2016, 183 : 2861 - 2869
  • [8] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yawen Yuan
    Yiqun Zheng
    Jinglei Liu
    Hua Wang
    Shifeng Hou
    [J]. Microchimica Acta, 2017, 184 : 4723 - 4729
  • [9] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yuan, Yawen
    Zheng, Yiqun
    Liu, Jinglei
    Wang, Hua
    Hou, Shifeng
    [J]. MICROCHIMICA ACTA, 2017, 184 (12) : 4723 - 4729
  • [10] A non-enzymatic hydrogen peroxide sensor based on poly(vinyl alcohol)-multiwalled carbon nanotubes-platinum nanoparticles hybrids modified glassy carbon electrode
    Fang, Yuxin
    Zhang, Di
    Qin, Xia
    Miao, Zhiying
    Takahashi, Shigehiro
    Anzai, Jun-ichi
    Chen, Qiang
    [J]. ELECTROCHIMICA ACTA, 2012, 70 : 266 - 271